NISTIR 6392 GSA Guide to Specifying InteroperableBuilding automation and Control SystemsUsing ANSI/ ashrae Standard 135-1995,BACnetSteven T. BushbyBuilding and Fire Research LaboratoryGaithersburg, MDH. Michael NewmanCornell UniversityIthaca, NYMartin A. ApplebaumESS Engineering, , AZUnited States Department of CommerceTechnology AdministrationNational Institute of Standards and TechnologyGaithersburg, MD 20899 NISTIR 6392 GSA Guide to Specifying InteroperableBuilding automation and Control SystemsUsing ANSI/ ashrae Standard 135-1995,BACnetSteven T. Bushby November, 1999 building and Fire Research LaboratoryGaithersburg, MDH.

NISTIR 6392 GSA Guide to Specifying Interoperable Building Automation and Control Systems Using ANSI/ASHRAE Standard 135-1995, BACnet Steven T. Bushby

Tags:

  Automation, Building, Ashrae, Specifying, To specifying interoperable building automation and, Interoperable

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of NISTIR 6392 GSA Guide to Specifying Interoperable …

1 NISTIR 6392 GSA Guide to Specifying InteroperableBuilding automation and Control SystemsUsing ANSI/ ashrae Standard 135-1995,BACnetSteven T. BushbyBuilding and Fire Research LaboratoryGaithersburg, MDH. Michael NewmanCornell UniversityIthaca, NYMartin A. ApplebaumESS Engineering, , AZUnited States Department of CommerceTechnology AdministrationNational Institute of Standards and TechnologyGaithersburg, MD 20899 NISTIR 6392 GSA Guide to Specifying InteroperableBuilding automation and Control SystemsUsing ANSI/ ashrae Standard 135-1995,BACnetSteven T. Bushby November, 1999 building and Fire Research LaboratoryGaithersburg, MDH.

2 Michael NewmanCornell UniversityIthaca, NYMartin A. ApplebaumESS Engineering, , AZ Department of CommercePrepared for:William M. Daley, General Services AdministrationTechnology AdministrationDavid J. Barram, AdministratorCheryl L. Shavers, Under Secretary for TechnologyNational Institute of Standards and TechnologyRaymond G. Kammer, DirectorAbstractThis Guide is intended for use by General Services Administration staff or design consultants whenpreparing specifications for Interoperable building control systems using BACnet technology.

3 Itexplains the issues that need to be considered when Specifying the communication details and makessome recommendations for the choices involved. It is not a sample specification and it does notaddress all issues important for a good control system specification. The focus is on specific issuesrelated to the interconnection and interoperation of building automation systems and devices usingBACnet. It is intended to complement more general guidelines for direct digital control systems forbuilding automation words: BACnet, building automation and control, direct digital control, energy managementsystems, communication protocol, ANSI/ ashrae Standard 135 AcknowledgmentsThe authors wish to acknowledge the significant contributions to this Guide made by the members ofASHRAE SSPC 135, the "BACnet Committee.

4 " Many of the ideas presented had their genesis indiscussions with committee members about ways to make it easier to specify BACnet of Contents1 PURPOSE OF THIS Interoperable BACNET Sharing - Specification Issues and AND EVENT and Event Management - Specification Issues and - Specification Issues and - Specification Issues and AND NETWORK and Network Management - Specification Issues and OF BACNET / DIAGNOSTIC OBJECT RELATED TO SPECIFIC BACNET OBJECT Input, Output, and Input, Output, and OBJECT OF BACNET Alarm up Notification Notification Message LEVELS OF AUTHORITY TO CERTAIN OF VALUE COV COV SYSTEM/NETWORK AREA NETWORK 8802-3, , , , , MAC ADDRESSES IN A CONSISTENT MAC MAC MAC MAC NUMBERING OBJECT IDENTIFIER OF BACNET WITH THE INTERNET H Tunneling 135a, - INTERCONNECTING MULTIPLE BACNET - CONNECTING TO LEGACY CONSIDERATIONS IN THE CONSTRUCTION OF BACNET Implementation Conformance Statements (PICS).

5 AND MAINTENANCE A. BACNET INTEROPERABILITY building BLOCKS (BIBBS).. Sharing-ReadProperty-A (DS-RP-A).. Data Sharing-ReadProperty-B (DS-RP-B).. Data Sharing-ReadPropertyMultiple-A (DS-RPM-A).. Data Sharing-ReadPropertyMultiple-B (DS-RPM-B).. Data Sharing-ReadPropertyConditional-A (DS-RPC-A).. Data Sharing-ReadPropertyConditional-B (DS-RPC-B).. Data Sharing-WriteProperty-A (DS-WP-A).. Data Sharing-WriteProperty-B (DS-WP-B).. Data Sharing-WritePropertyMultiple-A (DS-WPM-A).. Data Sharing-WritePropertyMultiple-B (DS-WPM-B).. Data Sharing-COV-A (DS-COV-A).

6 Data Sharing-COV-B (DS-COV-B).. Data Sharing-COV-Unsubscribed-A (DS-COVU-A).. Data Sharing-COV-Unsubscribed-B (DS-COVU-B).. AND EVENT MANAGEMENT Alarm and Event Notification-A (AE-N-A).. Alarm and Event Notification-B (AE-N-B).. Alarm and Event ACK-A (AE-ACK-A).. Alarm and Event ACK-B (AE-ACK-B).. Alarm and Event Summary-A (AE-ASUM-A).. Alarm and Event Summary-B (AE-ASUM-B).. Event Summary-A (AE-ESUM-A).. Event Summary-B (AE-ESUM-B).. Scheduling-A (SCHED-A).. Scheduling-B (SCHED-B).. Vewing and Modifying Trends-A (T-VMT-A).. Vewing and Modifying Trends-B (T-VMT-B).

7 Automated Trend Retrieval-A (T-ATR-A).. Automated Trend Retrieval-B (T-ATR-B).. MANAGEMENT Device Management - Dynamic Device Binding-A (DM-DDB-A).. Device Management - Dynamic Device Binding-B (DM-DDB-B).. Device Management - Dynamic Object Binding-A (DM-DOB-A).. Device Management - Dynamic Object Binding-B (DM-DOB-B).. Device Management - DeviceCommunicationControl-A (DM-DCC-A).. Device Management - DeviceCommunicationControl-B (DM-DCC-B).. Device Management - PrivateTransfer-A (DM-PT-A).. Device Management - PrivateTransfer-B (DM-PT-B).. Device Management - Text Message-A (DM-TM-A).

8 Device Management - Text Message-B (DM-TM-B).. Device Management - TimeSynchronization-A (DM-TS-A).. Device Management - TimeSynchronization-B (DM-TS-B).. Device Management - UTCTimeSynchronization-A (DM-UTC-A).. Device Management - UTCTimeSynchronization-B (DM-UTC-B).. Device Management - ReinitializeDevice-A (DM-RD-A).. Device Management - ReinitializeDevice-B (DM-RD-B).. Device Management - Backup and Restore-A (DM-BR-A).. Device Management - Backup and Restore-B (DM-BR-B).. Device Management - List Manipulation-A (DM-LM-A).. Device Management - List Manipulation-B (DM-LM-B).

9 Device Management - Object Creation and Deletion -A (DM-OCD-A).. Device Management - Object Creation and Deletion -B (DM-OCD-B).. MANAGEMENT Network Management - Connection Establishment -A (NM-CE-A).. Network Management - Connection Establishment -B (NM-CE-B).. Network Management - Router Configuration -A (NM-CE-A).. TERMINAL Virtual Terminal -A (VT-A).. Virtual Terminal -A (VT-B)..55 ANNEX AND PROFILES OF STANDARDIZED BACNET OPERATOR WORKSTATION (B-OWS).. building CONTROLLER (B-BC).. ADVANCED APPLICATION CONTROLLER (B-AAC).. APPLICATION SPECIFIC CONTROLLER (B-ASC).

10 SMART ACTUATOR (B-SA).. SMART SENSOR (B-SS).. GATEWAY (B-GW).. OF THE STANDARD BACNET BACNET IMPLEMENTATION Purpose of this GuideThis document has been produced for the General Services Administration (GSA) to foster abroad-based understanding and consistent application of ashrae /ANSI Standard 135-1995(BACnet ) for automation systems in Federal buildings in both new and retrofit such, GSA personnel and GSA s selected design consultants should utilize this document as aguide in planning, designing, procuring and managing projects involving building AutomationSystem (BAS)