US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse- hinds BusinessNon- metallic Arktite Heavy duty Circuit BreakingPlugs and ReceptaclesMade of Krydon Material, 600 VAC/250 VDC, 50 400 hertzWatertight Corrosion-ResistantNEMA 4 XApplications:Arktitecircuit Breaking plugs, receptacles,cord connectors and motor plugs are used: To supply power to portable electricaldevices such as welders, motors,pumps, conveyors and other similarequipment Where electrical loads must be quickly disconnected from power sources In areas where severe corrosion hosedown, moisture, dirt and dust are problems Indoors and outdoors in non-hazardousareas of chemical plants, sewage treatment facilities, cement plants, pulp and paper plants, food processing plants and other similar industriesFeatures: Plugs, receptacles, cord connectors, and motor plugs ar

1P www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1329 Non-metallic Arktite ® Heavy Duty Circuit Breaking

Tags:

  Course, Heavy, Duty, Circuit, Breaking, Hinds, Metallic, Metallic arktite heavy duty circuit breaking, Arktite, Metallic arktite, 174 heavy duty circuit breaking

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Non-metallic Arktite Heavy Duty Circuit Breaking ...

1 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse- hinds BusinessNon- metallic Arktite Heavy duty Circuit BreakingPlugs and ReceptaclesMade of Krydon Material, 600 VAC/250 VDC, 50 400 hertzWatertight Corrosion-ResistantNEMA 4 XApplications:Arktitecircuit Breaking plugs, receptacles,cord connectors and motor plugs are used: To supply power to portable electricaldevices such as welders, motors,pumps, conveyors and other similarequipment Where electrical loads must be quickly disconnected from power sources In areas where severe corrosion hosedown, moisture, dirt and dust are problems Indoors and outdoors in non-hazardousareas of chemical plants, sewage treatment facilities, cement plants, pulp and paper plants, food processing plants and other similar industriesFeatures.

2 Plugs, receptacles, cord connectors, and motor plugs are molded of Krydonfiberglass-reinforced polyester material which is highly resistant to corrosion, heat, weathering and physical abuseMolded of Krydon fiberglass-reinforced Non-metallic material which is highly resistant to corrosion, heat, weathering,and physical abuseGrounding contacts that make-first and break-last in the unlikely event of a keyway failureSplit-pin contact design provides 360 of electrical contactSpring door provides environmental protection of receptacle (NEMA 4)Keyed for a perfect match in the molded one-piece insulator housingSealing gaskets at all critical points inside Arktite plugs and receptacles protect against dust, dirt, mud, water, and corrosive contaminantsPlugs can be used in both hazardous and non-hazardous areas when used with appropriately rated Arktite receptaclesTotal interchangeability with all existing Arktite products for comparable ratings and configurationsA unique patented strain relief designprevents stress from reaching wireterminations at the contactsCertifications andCompliances: UL Standard.

3 1682 UL 1010 hazardous locations (NPJ plug only) Wet and damp locations, watertight CSA Standard No. of PlugsWith Other Non-hazardousand Hazardous LocationReceptacles: Plugs listed for use with NRE/NREA assemblies are standard NPJ Arktiteplugs. Other standard APJ and CPHplugs of the same rating, style andnumber of poles may be used with NRreceptacles, as well as with AR andAREA, receptacles listed in Section 1P,with DR receptacles listed in Section 2P,with DBR, NBR, NSR, WSR, CSR,WSQC, and WSRD receptacles listed inSection 3P and with FSQ, EPC, FSQC,W2SR, C2SR and EPCB receptacleslisted in Section 4P.

4 Portable equipment, suitable forlocations and equipped with the properNPJ plug, can be used with non-hazardous AR receptacles; with DBRand WSR interlocked receptacleslocated in non-hazardous locations; withEPC, EPCB and FSQC receptacles forClass I, Groups B, C, D hazardouslocations; with DR and DBR receptaclesfor Class II, Groups F, G hazardouslocations; and with NBR/NSR, CSRinterlocked receptacles for hose downand corrosive : NPJ plugs are Style 2, which includes agrounding conductor in the flexible cordor cable that is electrically connected tothe extra (grounding) pole. NR receptacles are Style 2, in which theground connection is made before lineand load poles engage, and is brokenafter line and load poles disengage.

5 The National Electrical Code andCanadian Electrical Code requires thatunder conditions favorable to corrosion,the grounding conductor for enclosuresand equipment be of copper or othercorrosion-resistant material in alternatingcurrent systems. This necessitatesrunning another conductor, usually ofcopper, back to the common groundingelectrode. This may be run through theconduit containing the circuitconductors. At the receptacle, thisgrounding conductor should beconnected to the extra (grounding) poleby the pressure connector provided forthat purpose. Where such an extraground conductor is required, Style 2receptacles should be Materials: Housing, interiors, spring doors,clamping rings Krydonfiberglass-reinforced polyester material Gaskets and o-rings neoprene Cable clamping basket nylon Contacts pressure brass.

6 Crimp/solder leaded brass Snap-on cap molded elastomer Back boxes copper-free aluminumStandard Finishes: Krydonmaterial natural (gray) Neoprene natural Elastomer natural Brass natural Leaded red brass electro-tin-plated Aluminum natural Stainless steel naturalOptions:DescriptionSuffix Alternate polarization (4-pole plugs andreceptacles only) receptacle interior rotated221/2 to right and plugchanged to Crimp/solder Corro-free epoxy powdercoat on back boxes andangle on request Wet and damp locations when used with spring door or snap-on cap, watertight when used with QE threaded US: 1-866-764-5454 CAN.

7 1-800-265-0502 Copyright 2013 Eaton s Crouse- hinds Business1 PNon- metallic Arktite Heavy duty CircuitBreaking Plugs and ReceptaclesMade of Krydon Material, 30 A, 60 A and 100 A600 VAC/250 VDC, 50 400 hertzWatertight Corrosion-ResistantNEMA 4 XReceptacle AssemblyReceptacleMating PlugsMating ConnectorsMotor PlugsNREANRE For use on systems less than 60 hertz the receptacles, plugs and connectors are for disconnect use only. Wet and damp locations when used with spring door or snap-on cap, watertight when used with QE threaded cap. Krydon Arktite Receptacles are supplied with both a spring door and snap-on cap.

8 AJ back boxes are square, making it possible to install with hub in several DescriptionHubSize (In.)Snap-on Cap/Spring DoorCat. # Snap-on Cap/Spring DoorCat. # Cat. #Cord ConnectorCat. #Motor PlugCat. #302-wire,3-pole3 ,4-pole3 , ,4-pole11 ,3-pole11/4 NREA10324 ,4-pole11/2 NREA10425 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse- hinds BusinessNon- metallic Arktite Heavy duty CircuitBreaking Plugs and ReceptaclesMade of Krydon Material, 30 A, 60 A and 100 A600 VAC/250 VDC, 50 400 hertzDimensionsDimensionsIn Inches:Fig.

9 1 30 A Receptacle AssembliesFig. 2 60 A Receptacle AssembliesFig. 3 60 and 100 A ReceptacleAssembliesNRE 30 and 60 A Assemblies Fig. 1 and 2 Dimension a Dimension bHub Size30 A60 A30 A60 A3/413/1617/8115/1615/16229/1611/413/162 5/811/215/16211/16 NREA 60 and 100 A Assemblies Fig. 360 A Hub Size 100 A Hub , 11/4, 11/211/4, 11/22a991/4913/16b111212c115/1619/1619/1 6 Fig. 4 Spring Door HousingsFig. 5 Housings with CapFig. 6 NPQ Motor PlugsFig. 7 NPJ PlugsFig. 8 NPR Cord ConnectorsNPQ Motor Plugs Fig. 6 Amps/Polesabc30/ 3 or 423/433/8215/1660/ 3 or 431/241/445/16100/ 3 or 431/241/457/16 NPJ Plugs Fig.

10 7 Amps/Polesabc30/ 3 or 481/2733/1660/ 391/2613/1635/860/ 491/2613/164100/ 3111/473/44100/ 4111/473/441/4 NPR Cord Connectors Fig. 8 Amps/Polesabc30/ 3 or 487/829/1625/860/ 393/4215/16215/1660/ 493/431/4215/16100/ 3111/233/1635/16100/ 4111/237/1635/16 For use on systems less than 60 hertz the receptacles, plugs and disconnectors are for disconnect use - Fig. 4 and 5 AmpsNo. Poles Housingabcde303 or 4 Spring Door31/433/8 23/412 243 or 4 Open213/1633/829/1623/412 24603 Spring Door41/241/4 31/25/16-184 Spring Door41/241/4 31/25/16-183 Open41/1641/4215/1631/25/16-184 Open41/1641/431/431/25/16-181003 Spring Door53/441/4 31/25/16-184 Spring Door53/441/4 31/25/16-183 Open55/1641/433/1631/25/16-184 Open55/1641/437/1631/25/16-18