Example: air traffic controller

November 2021 Rosemount 5900S Reference Manual

Reference Manual00809-0100-5900, Rev EBNovember 2021 Rosemount 5900 SRadar Level GaugeRosemount 5900S Radar Level GaugeNOTICERead this Manual before working with the product. For personal and system safety, and for optimum product performance,ensure you thoroughly understand the contents before installing, using, or maintaining this equipment service or support needs, contact your local Emerson Automation Solutions/ Rosemount Tank PartsAny substitution of non-recognized spare parts may jeopardize safety. repair , substitution of components etc, may alsojeopardize safety and is under no circumstances Tank Radar AB will not take any responsibility for faults, accidents, etc caused by non-recognized spare parts or anyrepair which is not made by Rosemount Tank Radar ETSI Requirements (Europe)The Rosemount 5900S is required to be installed at a permanent fixed position a

Repair, e.g. substitution of components etc, may also jeopardize safety and is under no circumstances allowed. Rosemount Tank Radar AB will not take any responsibility for faults, accidents, etc caused by non-recognized spare parts or any repair which is not made by Rosemount Tank Radar AB. Specific ETSI Requirements (Europe)

Tags:

  Repair

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of November 2021 Rosemount 5900S Reference Manual

1 Reference Manual00809-0100-5900, Rev EBNovember 2021 Rosemount 5900 SRadar Level GaugeRosemount 5900S Radar Level GaugeNOTICERead this Manual before working with the product. For personal and system safety, and for optimum product performance,ensure you thoroughly understand the contents before installing, using, or maintaining this equipment service or support needs, contact your local Emerson Automation Solutions/ Rosemount Tank PartsAny substitution of non-recognized spare parts may jeopardize safety. repair , substitution of components etc, may alsojeopardize safety and is under no circumstances Tank Radar AB will not take any responsibility for faults, accidents, etc caused by non-recognized spare parts or anyrepair which is not made by Rosemount Tank Radar ETSI Requirements (Europe)The Rosemount 5900S is required to be installed at a permanent fixed position at a closed (not open) metallic tank or reinforcedconcrete tank, or similar enclosure structure made of comparable attenuating material.

2 Flanges and attachments of theRosemount 5900S equipment shall provide the necessary microwave sealing by or connection flanges at the tank shall be closed to ensure a low-level leakage of the signal into the air outside the and maintenance of the Rosemount 5900S equipment shall be performed by professionally trained individuals FCC Requirements (USA) Rosemount 5900S generates and uses radio frequency energy. If it is not installed and used properly, that is, in strict accordancewith the manufacturer s instructions, it may violate FCC regulations on radio frequency TankRadar 5900S has been FCC certified under test conditions which assume a metallic IC Requirements (Canada)Radio approvals for this device apply for installation in complete enclosed container to prevent unwanted RF emission.

3 In open airapplication site license is required. Installation shall be done by trained installers, in compliance with the manufacturer' use of this device is on a "no-interference, no-protection" basis. That is, the user shall accept operations of high-powered radarin the same frequency band which may interfere with or damage this device. Devices found to interfere with primary licensingoperations will be required to be removed at the user's Emission of Microwave RadiationThe microwave radiation emitted by a Rosemount 5900S radar level gauge is very low compared to limits given by the (much less than mW).

4 No additional safety measures are needed. CAUTIONThe products described in this document are NOT designed for nuclear-qualified applications. Using non-nuclear qualifiedproducts in applications that require nuclear-qualified hardware or products may cause inaccurate readings. For information onRosemount nuclear-qualified products, contact your local Emerson Sales Representative. WARNINGWARNING - Substitution of components may impair Intrinsic - La substitution de composants peut compromettre la s curit intrins - To prevent ignition of flammable or combustible atmospheres, disconnect power before - Ne pas ouvrir en cas de presence d'atmosphere Safety Manual Technical Service Product Packing Main QR System Installation Safety Installation Mechanical Electrical Safety Configuration using Rosemount Basic Advanced LPG Calibration using FOUNDATION Fieldbus Device General block Analog Input Analog Output Resource 475 Field Communicator Menu ManualContents00809-0100-5900 November 2021 Rosemount 5900S Radar Level Configuration using AMS

5 Device Alert LPG Setup using DeltaV / AMS Device Safety Viewing measurement data in Rosemount Alarm Viewing measurement data in AMS Device 185 Chapter 6 Service and Safety Resource block error Transducer block error Analog Input (AI) function Viewing device status in AMS Device ASpecifications and Reference Communication/ FOUNDATION Fieldbus Rosemount 5900S SIL 2 version (SIS option code S).. Rosemount 5900S SIL 3 version (SIS option code 3).. Rosemount 5900S with parabolic Rosemount 5900S with horn Rosemount 5900S with still-pipe array Rosemount 5900S with LPG/LNG Dimensional Ordering 240 Appendix BProduct European directive Ordinary Location Telecommunication Installing Equipment in North North ManualNovember 202100809-0100-59004 Reference Technical Regulations Customs Union (EAC).

6 Republic of United Arab Additional Custody Transfer Product Certifications Rosemount Approval 279 Appendix CFOUNDATION Fieldbus Block Resource block Analog Input block system Analog Output block system Measurement Transducer Volume Transducer Register Transducer block Advanced Configuration Transducer LPG Transducer block .. Supported ManualContents00809-0100-5900 November 2021 Rosemount 5900S Radar Level Gauge5 ContentsReference ManualNovember 202100809-0100-59006 Reference messagesInstructions and procedures in this section may require special precautions to ensure thesafety of the personnel performing the operations.

7 Information that potentially raisessafety issues is indicated by a warning symbol (). Refer to the following safety messagesbefore performing an operation preceded by this symbol. WARNINGF ailure to follow these installation guidelines could result in death or serious injury. Ensure only qualified personnel perform the installation. Use the equipment only as specified in this Manual . Failure to do so may impair theprotection provided by the could result in death or serious injury. Verify that the operating atmosphere of the transmitter is consistent with theappropriate hazardous locations certifications.

8 Before connecting a handheld communicator in an explosive atmosphere, ensure thatthe instruments in the loop are installed in accordance with intrinsically safe or non-incendive field wiring practices. Do not remove the gauge cover in explosive atmospheres when the circuit is shock could cause death or serious injury. Use extreme caution when making contact with the leads and terminals. WARNINGAny substitution of non-recognized parts may jeopardize safety. repair ( substitutionof components) may also jeopardize safety and is not allowed under any circumstances. WARNINGP hysical accessUnauthorized personnel may potentially cause significant damage to and/ormisconfiguration of end users equipment.

9 This could be intentional or unintentional andneeds to be protected security is an important part of any security program and fundamental toprotecting your system. Restrict physical access by unauthorized personnel to protect endusers assets. This is true for all systems used within the ManualIntroduction00809-0100-5900 November 2021 Rosemount 5900S Radar Level 1-1: SymbolsThe CE marking symbolizes the conformity of the product with the applicableEuropean Community EU-Type Examination Certificate is a statement of a Notified CertificationBody declaring that this product meets the Essential Health and SafetyRequirements of the ATEX directive The FM APPROVED Mark indicates that the equipment is approved byFM Approvals according to applicable Approval Standards and is applicable forinstallation in hazardous locationsProtective EarthGround External cabling must be approved for use in min.

10 81 CIntroductionReference ManualNovember 202100809-0100-59008 Reference overviewThis Manual provides installation, configuration, and maintenance information for theRosemount 5900S Series Radar Level Gauge. The Manual is based on a typical RosemountTank Gauging system with a Rosemount 2410 Tank Hub connected to supported devicessuch as the Rosemount 5900S . It also includes a brief overview of FOUNDATION Fieldbus,and provides device specific information to allow installation of a Rosemount 5900S inFoundation fieldbus Overview provides a brief description of the various components in a RosemountTank Gauging system and recommended installation Installation covers installation considerations as well as mechanical and Configuration describes how to configure the Rosemount 5900S by using toolssuch as Rosemount TankMaster, Rosemount 475 Field Communicator, or AMS DeviceManager.


Related search queries