Example: bachelor of science

NPW -Series - Valve Regulated Lead Acid Batter y

NPW45-12 (FR)Nominal voltage12V20-hr rate Capacity to at 20 rate Capacity to at 20 ( 1)mmWidth65 ( 1)mmHeight94 ( 1)mm(height over terminals) ( 2)mmMass (typical) (Quickfit / release) ChargeDischargeLAYOUTC apacity loss per month at 20 C (approx)3%Standard OptionFlame retardant option (FR) ( 1%) ( 1%)V/cellFloat Charge voltage temperature correction factor (for variations from the standard 20 C)-3mV/cell/ ( 3%) ( 3%)V/cellCyclic Charge voltage temperature correction factor (for variations from the standard 20 C)-4mV/cell/ CFloat charge current limitNo limitACyclic (or Boost) charge current limit second105A1 minute42 AInternal resistanceN/Am 3RD PARTY CERTIFICATIONSS hort-Circuit currentN/AAISO 9001 - Quality Management SystemsISO 14001 - Environmental Management SystemsMeasured at 1 kHz24m EN 18001 - OHSAS Management SystemsUNDERWRITERS LABORATORIES to the technical manualNPWSTANDARDSEUROBAT Classification: Standard Commercial3 to 5yearsIEC61056 Yuasa design life @ 20 Cup to 5yearsALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICEI ssue No.

NPW45-12 (FR) Nominal voltage 12 V 20-hr rate Capacity to 1.75VPC at 20¡C 8.5 Ah 10-hr rate Capacity to 1.75VPC at 20¡C 7.42 Ah Length 151 (±1) mm

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of NPW -Series - Valve Regulated Lead Acid Batter y

1 NPW45-12 (FR)Nominal voltage12V20-hr rate Capacity to at 20 rate Capacity to at 20 ( 1)mmWidth65 ( 1)mmHeight94 ( 1)mm(height over terminals) ( 2)mmMass (typical) (Quickfit / release) ChargeDischargeLAYOUTC apacity loss per month at 20 C (approx)3%Standard OptionFlame retardant option (FR) ( 1%) ( 1%)V/cellFloat Charge voltage temperature correction factor (for variations from the standard 20 C)-3mV/cell/ ( 3%) ( 3%)V/cellCyclic Charge voltage temperature correction factor (for variations from the standard 20 C)-4mV/cell/ CFloat charge current limitNo limitACyclic (or Boost) charge current limit second105A1 minute42 AInternal resistanceN/Am 3RD PARTY CERTIFICATIONSS hort-Circuit currentN/AAISO 9001 - Quality Management SystemsISO 14001 - Environmental Management SystemsMeasured at 1 kHz24m EN 18001 - OHSAS Management SystemsUNDERWRITERS LABORATORIES to the technical manualNPWSTANDARDSEUROBAT Classification: Standard Commercial3 to 5yearsIEC61056 Yuasa design life @ 20 Cup to 5yearsALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICEI ssue No.

2 : / Issue Date: July 2010 Batteries must not be suspended by their handles (where fitted)Vent valvesEach cell is fitted with a low pressure release Valve to allow gasses to escape and then ReleaseVRLA Batteries release hydrogen gas which can form explosive mixtures in air. Do not place inside a sealed containerRecyclingYUASA's VRLA batteries must be recycled at the end of life in accordance with local and national laws and regulationsInstallationCan be installed and operated in any orientation except permanently invertedHandlesSHORT-CIRCUIT CURRENT & INTERNAL RESISTANCE(according to EN IEC 60896-21)IMPEDANCEDESIGN LIFEPERFORMANCE & CHARACTERISTICSCHARGE VOLTAGE-15 C to +40 C-0 C to +40 CSAFETY Float charge voltage at 20 CCyclic (or Boost) charge at 20 CCHARGE CURRENTMAXIMUM DISCHARGE CURRENTNPW -Series - Valve Regulated Lead Acid Battery-15 C to +50 CABS ( :HB)ABS (UL94:V0)SPECIFICATIONSDIMENSIONSTERMINA L TYPEOPERATING TEMPERATURE RANGESTORAGECASE MATERIAL