Example: bachelor of science

OCEAN AUTOMATION SOLUTIONS

OCEAN AUTOMATION MMC INTERNATIONAL CORP. OPERATING AND MAINTENANCE INSTRUCTIONS INTRINSICALLY SAFE TRIPLE FUNCTION GAUGING TAPE FOR RESTRICTED APPLICATIONS liquid MEASURE OF ULLAGE, OIL/WATER AND TEMPERATURE MODEL D-2401-2 TECHNICAL APPROVED BY: FACTORY MUTUAL AND BASEEFA FOR CLASS I, DIVISION I, GROUPS C & D AND LLOYD'S REGISTER AND BUREAU VERITAS "MED" APPROVED IN ACCORDANCE WITH IMO RESOLUTION (XIII) FOR OIL/WATER DETECTION MMC INTERNATIONAL CORP 60 INIP DRIVE INWOOD, NEW YORK 11096 AUG 2006 DRAWING FILE NO.

mmc international corp. operating and maintenance instructions intrinsically safe triple function gauging tape for restricted applications liquid measure of ullage, oil/water

Tags:

  Solutions, Automation, Liquid, Canoe, Ocean automation solutions

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of OCEAN AUTOMATION SOLUTIONS

1 OCEAN AUTOMATION MMC INTERNATIONAL CORP. OPERATING AND MAINTENANCE INSTRUCTIONS INTRINSICALLY SAFE TRIPLE FUNCTION GAUGING TAPE FOR RESTRICTED APPLICATIONS liquid MEASURE OF ULLAGE, OIL/WATER AND TEMPERATURE MODEL D-2401-2 TECHNICAL APPROVED BY: FACTORY MUTUAL AND BASEEFA FOR CLASS I, DIVISION I, GROUPS C & D AND LLOYD'S REGISTER AND BUREAU VERITAS "MED" APPROVED IN ACCORDANCE WITH IMO RESOLUTION (XIII) FOR OIL/WATER DETECTION MMC INTERNATIONAL CORP 60 INIP DRIVE INWOOD, NEW YORK 11096 AUG 2006 DRAWING FILE NO.

2 A-2401-60 OCEAN AUTOMATION TABLE OF CONTENTS PAGE NUMBER NOTICES i I. GENERAL SPECIFICATIONS .. 1 LINEAR ACCURACY SPECIFICATIONS .. 2 SPECIAL FEATURES .. 3 II. INTRODUCTION .. 4 III. THEORY OF OPERATION .. 5 IV. REQUIRED CONDITIONS AND RECOMMENDATIONS FOR SAFE USAGE REQUIRED CONDITIONS.. 7 RECOMMENDED SAFE USAGE CONDITIONS .. 7 V. OPERATION FAMILIARIZATION WITH OPERATING CONTROLS AND FEATURES LOCATED ON THE TAPE REEL HUB COVER PANEL.

3 8 ULLAGE/INTERFACE MEASUREMENTS .. 8 TEMPERATURE MEASUREMENT PROCEDURE .. 10 VI. CARE AND MAINTENANCE .. 11 VII. CALIBRATION PROCEDURE ULLAGE AND INTERFACE .. 12 TEMPERATURE SENSOR CALIBRATION .. 12 VIII. GAUGING TAPE REPLACEMENT .. 14 IX. HUB COVER AND P. C. BOARD REPLACEMENT .. 15 X. FAULT FINDING .. 16 XI. APPENDIX .. 18 XII. LIST OF DRAWINGS .. 45 OCEAN AUTOMATION TO ALL EQUIPMENT USERS If your gauging device has been equipped with an all Stainless Steel Triple Function Sensor (Material Type 316SS).

4 The triple functions of this sensor are to detect cargo surface level, Ullage, the Interface between two immiscible products such as oil and water, and cargo Temperature. The normal order of the gauging device, response to the products "Ullage level", is a steady horn tone. The normal response to an "Interface level", (" " between a non-conducting and a electrically conducting product such as a petroleum product and water, is a "steady" tone changing to a "beeping" tone, at the interface level. A special note to our chemical customers, is the fact that some chemical cargoes may be inherently conductive.)

5 Therefore, at the surface of a conductive product's Ullage level, a "beeping" tone will be the normal response. As a further note to the above, the change in detection of a non-conductive product Ullage level as a steady tone to that of a conductive product's ullage "beeping" tone, it is not to conclude that the sensor is malfunctioning. The all stainless steel Triple Function sensor is IMO Resolution (XIII) approved, and therefore also meets the International requirements of a petroleum carrier, or a dual classed chemical / petroleum carrier.

6 We hope that this sensor performs satisfactorily for all your applications and we would appreciate any return comments you may have concerning its response to various products. Best Regards, MMC International Corp. i OCEAN AUTOMATION I I. GENERAL SPECIFICATIONS: Display Readable Temperature Range .. F = -40 to * *Reading Limit Due to 3-1/2 Digit LCD Display on F Range. C = -40 to Guaranteed Temperature Calibration Range.

7 32 F to 190 F (and 0 C to 88 C) Accuracy Over Calibration Range .. F ( C) Accuracy Linear Measurements .. 1/8 ( ), Plus of Total Tape Length, worst case Minimum Detectable Tank Bottom liquid Level .. 3/8 (10MM) Minimum Detectable Floating Product Level .. 1/8 (3MM) Batteries for Intrinsically Safe Operation Only (supplied).

8 9 Volt Eveready #522 or Duracell MN1604 Battery Drain (Temperature Mode) .. ma (In Air) ma (In Fluid) Display .. 3-1/2 Digit liquid Crystal Display 1/2 Character Height Operating Temperature Limit of liquid Crystal Display, -40 F to 176 F Ambient Conditions.

9 -40 C to 80 C Storage Temperature Limits .. -67 F to 185 F -55 C to 85 C Available Tape Length - Single Face Scale .. 50 FT or 15 Meters 75 FT or 25 Meters 100 FT or 30 Meters 100 FT (10ths & 100ths)

10 120 FT (37 Meters) Hazardous Environments .. Certified Intrinsically Safe BASEEFA and Factory Mutual Gas Groups C&D Page 1 OCEAN AUTOMATION LINEAR ACCURACY SPECIFICATION.