Example: marketing

Odor Measurement Review

Measurement of Odor Threshold by Triangle Odor Bag Method 118 Measurement of Odor Threshold by Triangle Odor Bag Method Yo s h i o Nagata Japan Environmental Sanitation Center 10-6 yotuyakamichou kawasaki-ku kawasaki-si kanagawa-ken E-mail : nagata-y@ Keywords Odor threshold , Triangle odor bag method , Reproducibility Abstract The detection thresholds of odor substances analyzed in field investigations were measured by the triangle odor bag method1). The number of substances used for the experiment is 223. The experiment was carried out from 1976 to 1988.

Measurement of Odor Threshold by Triangle Odor Bag Method -121- 3.3 Relation between threshold and Molecular Weight Although a clear tendency is not …

Tags:

  Measurement

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Odor Measurement Review

1 Measurement of Odor Threshold by Triangle Odor Bag Method 118 Measurement of Odor Threshold by Triangle Odor Bag Method Yo s h i o Nagata Japan Environmental Sanitation Center 10-6 yotuyakamichou kawasaki-ku kawasaki-si kanagawa-ken E-mail : nagata-y@ Keywords Odor threshold , Triangle odor bag method , Reproducibility Abstract The detection thresholds of odor substances analyzed in field investigations were measured by the triangle odor bag method1). The number of substances used for the experiment is 223. The experiment was carried out from 1976 to 1988.

2 As the results of the experiments, the odor thresholds were distributed over the concentration of large range depending on the odor substances. Isoamyl mercaptane exhibited the lowest threshold ( ), and propane exhibited the highest threshold (1500ppm). The distribution of thresholds expresses the normal distribution. Sulfur compounds with the exception of sulfur dioxide and carbon disulfide have the comparatively low threshold. It is showed the tendency that threshold becomes low as the increase of molecular weight in a certain range of molecular weight.

3 When the dispersion of odor thresholds for the same substance was shown at the ratio of the highest to the lowest odor threshold tested, the dispersion of odor thresholds was about 5 at the maximum. The thresholds of 223 substances measured by our laboratory were considered to be the average values with small bias comparatively. 1. Introduction The thresholds were needed also in the evaluation based on instrumental measuring method, and also in the evaluation based on olfactory measuring method in odor studies.

4 On that occasion, the data of the threshold by the foreign researcher, for example, Leonardos et al. (53 substances)2) or Hellman et al. (101substances)3), has greatly been made reference in Japan. But, the thresholds of substances that aren't reported to these literatures are also needed. And, a threshold may vary considerably in the difference of measuring method to the same material. Therefore, the need to measure thresholds individually is arising. The detection thresholds of 223 substances detected in various odor sources were measured in our laboratory by the triangle odor bag method4).

5 2. Odorants and experimental method Preparation of primary odor sample The standard gas such as the sulfurous acid gas taken from the standard gas bomb was injected in polyester bag filled with nitrogen gas using gastightsyringe. In case the Measurement of Odor Threshold by Triangle Odor Bag Method 119 reagent was liquid, the primary odor sample was prepared by vaporizing, after it was injected in polyester bag filled with nitrogen gas with microsyringe. And in case the reagent was a solid like Skatole, the sublimation gas was collected in the bag.

6 The odor samples were left for 2 hours or more in order to stabilize their gas concentration. Concentration Measurement of primary odor sample Ammonia was measured by indophenol method, diosmin, skatole, indole were measured by gas chromatography-mass spectrometry. Other odorants were measured by gas chromatography (FID, FPD, FTD). In case of the standard gas such as sulfur dioxide, the concentration displayed on the bomb were used. Measurement of odor concentration , and odor panel The odor concentration was measured by the triangle odor bag method.

7 In the triangle odor bag method, the threshold is obtained by detecting the difference from odor-free background. Therefore, the odor thresholds reported are nearly equal to the detection threshold. The Measurement of the threshold was carried out in 12 years from 1976 to 1988 (Figure 1). An odor panel consists of 6 panelists. All panelists have passed the panel screening test by T&T olfactometer. Their ages are 50-year-old from 20-year-old. Some panelists changed in these 12 years. However, four persons (woman) among 6 panelists are the panelists from the first time.

8 All panelists are trained. Calculation of threshold value In this examination, the value which divided the concentration of the primary odor sample by the odor concentration as a principle was determined as the detection threshold (ppm,v/v). detection threshold (ppm,v/v) = the concentration of primary odor sample/ odor concentration As shown in Table 1, about the odorants such as amines, fatty acids, skatole and indole, since the dilution error was large compared with other substances, their thresholds were corrected by their 5324816342925451601020304050601976 77 78 79 80 81 82 86 87 88 YearThe number of odorantsFigure 1 Carried-out year and the measured number of substances Table1 Dilution error of the odor bag *The injector made from a plastic was used.

9 The glass injector was used in the result of others. SubstancePrimary odorRecovery rate Hydrogen sulfide 2010 300 102 Methyl mercaptane 10 10 300 93 Dimethyl sulfide 8010 300 100n -Hexane 60010 1000 98 Toluene 900 10 1000 94n-Nonane 80010 1000 93o,m,p - Xylene 2310 1000 99 Styrene 2210 1000 105 Ammonia 110010 1000 95 Trimethylamine 10 3000 50 30 3000 93* 13 Propionaldehyde 100 300 82lsobutylaldehyde 100 300 82n-Valeraldehyde 100 300 83n-Butyric acid 10 30 40 Isobutyric acid 83 1000 3000 35 Isovaleric acid

10 10 30 39 Indole 30 100 30 3000 13 Dilution multiple Measurement of Odor Threshold by Triangle Odor Bag Method 120 recovery rate. About the odorants of which the thresholds were measured repeatedly, the geometric mean of each observed value was taken as the threshold of the odorant. 3. Result of threshold Measurement The thresholds of 223 odorants measured in the experiment are shown in the Table 2. The thresholds in the wide range of about 2 billion times to 1500ppm (propane) from (Isoamyl mercaptane) were observed.