Example: air traffic controller

Operating instruc- tions - Glow-worm

The energy you needOperating instruc- tionsUltimate 230c35cGB, IEContents2 Operating instructions Ultimate 2 0020206374_02 Contents1 warnings .. use .. safety 42 Notes on the documentation .. other applicabledocuments .. of the 73 Product label .. number .. on the identificationplate .. of the operator controlelements .. of the of button functions .. 104 up the product .. the heating systempressure .. the heating the Operating mode .. the hot watertemperature.

comply with the basic requirements of the applicable directives as stated on the iden-tification plate. The declaration of conformity can be viewed at the manufacturer's site. 3.2 Serialnumber 1 2 The serial number is located on the identi-fication plate (1)and in the short operating instructions (2)(→Page 7). 3.3 Informationonthe ...

Tags:

  Requirements

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Operating instruc- tions - Glow-worm

1 The energy you needOperating instruc- tionsUltimate 230c35cGB, IEContents2 Operating instructions Ultimate 2 0020206374_02 Contents1 warnings .. use .. safety 42 Notes on the documentation .. other applicabledocuments .. of the 73 Product label .. number .. on the identificationplate .. of the operator controlelements .. of the of button functions .. 104 up the product .. the heating systempressure .. the heating the Operating mode .. the hot watertemperature.

2 The heating flowtemperature .. settings .. the Switching the product tostandby mode .. Frost 135 Troubleshooting .. and rectifying codes in the display .. 146 Care and maintenance .. for the product .. the condensate drainpipework and 147 decommissioningthe product .. decommissioningthe product .. 148 Recycling and 149 Guarantee and customerservice .. 16A Operator level overview .. 16B Troubleshooting .. 16 Safety 10020206374_02 Ultimate 2 Operating instructions31 Action-related warningsClassification of action-re-lated warningsThe action-related warningsare classified in accordancewith the severity of the pos-sible danger using the followingwarning signs and signal words:Warning symbols and signalwordsDanger!

3 Imminent danger to lifeor risk of severe personalinjuryDanger!Risk of death from of minor of material or envir-onmental Intended useThere is a risk of injury or deathto the user or others, or of dam-age to the product and otherproperty in the event of im-proper use or use for which itis not product is intended as aheat generator for closed cent-ral heating installations and forhot water use includes the fol-lowing: observance of the operatinginstructions included for theproduct and any other systemcomponents compliance with all inspectionand maintenance conditionslisted in the product can be used bychildren aged from 8 yearsand above and persons withreduced physical, sensory ormental capabilities or lack ofexperience and knowledge ifthey have been given supervi-sion or instruction concerninguse of the product in a safe wayand understand the hazards in-volved.

4 Children shall not playwith the product. Cleaning anduser maintenance shall not bemade by children without super-vision. Children must not playwith the product. Cleaning anduser maintenance work mustnot be carried out by childrenunless they are other use that is not spe-cified in these instructions, oruse beyond that specified in thisdocument shall be consideredimproper use. Any direct com-1 Safety4 Operating instructions Ultimate 2 0020206374_02mercial or industrial use is alsodeemed to be use of any kind General Installation by skilledtradesmen onlyThe installation, inspection,maintenance and repair of theproduct, as well as the gas ratiosettings, must only be carriedout by a competent Danger caused byimproper operationImproper operation may presenta danger to you and others, andcause material damage.

5 Carefully read the enclosedinstructions and all other ap-plicable documents, particu-larly the "Safety" section andthe Risk of death fromescaping gasWhat to do if you smell gas inthe building: Avoid rooms that smell ofgas. If possible, open doors andwindows fully and ensureadequate ventilation. Do not use naked flames ( , matches). Do not smoke. Do not use any electricalswitches, mains plugs, door-bells, telephones or othercommunication systems inthe building. If it is safe to do so, close theemergency control valve orthe main isolator. If possible, close the gas isol-ator cock on the product.

6 Warn other occupants in thebuilding by yelling or bangingon doors or walls. Leave the building immedi-ately and ensure that othersdo not enter the building. Notify the gas supply com-pany or National Grid Transco+44 (0) 800 111999 by tele-phone from outside of Risk of death due to ablocked or leaking fluegas pipeWhat to do if you smell flue gasin the property: Open all accessible doorsand windows fully to provideventilation. Switch off the product. Inform a competent 10020206374_02 Ultimate 2 Operating Risk of death fromescaping flue gasIf you operate the product withan empty condensate siphon,flue gas may escape into theroom air.

7 In order to operate theproduct, ensure that the con-densate siphon is always Risk of death due toexplosive and flammablematerials Do not use or store explosiveor flammable materials ( , paper, paint) in the in-stallation room of the Risk of death due to lackof safety devicesA lack of safety devices ( relief valve, expan-sion vessel) can lead to poten-tially fatal scalding and otherinjuries, due to explosions. Ask a competent personto explain how the safetydevices work and where theyare Risk of death dueto changes to theproduct or the productenvironment Never remove, bridge orblock the safety devices.

8 Do not alter the safetydevices in any way. Do not damage or removeany seals on components. Do not make any changes: The product itself to the gas, air, water andelectricity supplies to the entire flue gas install-ation to the entire condensatedrain system to the expansion relief valve to the drain lines to constructional condi- tions that may affect theoperational reliability of Risk of injury andmaterial damage due tomaintenance and repairscarried out incorrectly ornot carried out at all Never attempt to carry outmaintenance work or repairson your product yourself.

9 Faults and damage shouldbe immediately rectified by acompetent person. Adhere to the maintenanceintervals Safety6 Operating instructions Ultimate 2 Risk of corrosiondamage due tounsuitable combustionand room airSprays, solvents, chlorinatedcleaning agents, paint, adhes-ives, ammonia compounds,dust or similar substances maylead to corrosion on the productand in the air/flue pipe. Ensure that the supply ofcombustion air is always freeof fluorine, chlorine, sulphur,dust, etc. Ensure that no chemical sub-stances are stored at the in-stallation Risk of materialdamage caused byfrost Ensure that the heating in-stallation always remains inoperation during freezing con-ditions and that all rooms aresufficiently heated.

10 If you cannot ensure the op-eration, have a competentperson drain the heating on the documentation 20020206374_02 Ultimate 2 Operating instructions72 Notes on Observing other applicabledocuments You must observe all Operating instruc- tions enclosed with the system Storing documents Keep this manual and all other applic-able documents safe for future Applicability of theinstructionsThese instructions apply only to:Product article numberArticle num-berGas CouncilNumberULTIMATE 230c001001612447-019-35 ULTIMATE 235c001001612547-019-36 These products are only designed for nat-ural gas Product CE label The CE label shows that the productscomply with the basic requirements of theapplicable directives as stated on the iden-tification declaration of conformity can beviewed at the manufacturer's Serial number 12 The serial number is located on the identi-fication plate(1)and in the short operatinginstructions(2)( Page 7).


Related search queries