Example: dental hygienist

Operating Instructions SCHRIEVER & SCHULZ

Frequency Measurement andSwitching InstrumentsSeries T400T401 - T402 Operating Instructions383E-64618T401 : One Channel tachometer with relay and 0/4-20 mA output : 383Z-05307T402 : One Channel tachometer with relay and 0/2-10 V output : 383Z-05308 berreicht durch / present by : SCHRIEVER & SCHULZ & Co. GmbHVertriebsb ro f r Mess- & Regeltechnik seit 1958 Eichstr. 25 30880 Laatzen Tel. ++49 (0) 511 86 45 41 /Fax ++49 (0) 511 86 41 56 || Instructions T401 T402 JAQUET LTDstatus : 2/18 /Contents :1 SAFETY INSTRUCTIONS32 FUNCTIONAL PURPOSE33 SPECIFICATIONS34 PRINCIPLE OF OPERATION75 INSTALLATION86 CONFIGURATION WITH PC SOFTWARE AND Software List of Parameters and Text Machine Factor (Configuration System Machine Factor) Minimum Measuring Time (Configuration System Fix Time) Minimum Displayed Measured Value (Configuration Syst)

Operating instructions T401 – T402 JAQUET LTD status : 2.3.2005 3/18 / 1 Safety instructions

Tags:

  Instructions

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Operating Instructions SCHRIEVER & SCHULZ

1 Frequency Measurement andSwitching InstrumentsSeries T400T401 - T402 Operating Instructions383E-64618T401 : One Channel tachometer with relay and 0/4-20 mA output : 383Z-05307T402 : One Channel tachometer with relay and 0/2-10 V output : 383Z-05308 berreicht durch / present by : SCHRIEVER & SCHULZ & Co. GmbHVertriebsb ro f r Mess- & Regeltechnik seit 1958 Eichstr. 25 30880 Laatzen Tel. ++49 (0) 511 86 45 41 /Fax ++49 (0) 511 86 41 56 || Instructions T401 T402 JAQUET LTDstatus : 2/18 /Contents :1 SAFETY INSTRUCTIONS32 FUNCTIONAL PURPOSE33 SPECIFICATIONS34 PRINCIPLE OF OPERATION75 INSTALLATION86 CONFIGURATION WITH PC SOFTWARE AND Software List of Parameters and Text Machine Factor (Configuration System Machine Factor) Minimum Measuring Time (Configuration System Fix Time) Minimum Displayed Measured Value (Configuration System Min etc) Definition of the Alarm (Configuration System Alarm Definition) Sensor Current Minimum (Configuration Sensor Current Min) Sensor Current Maximum (Configuration Sensor Current Max) Measuring Range Starting Value (Configuration Analog Output)

2 Measuring Range End Value (Configuration Analog Output) Output Range (Configuration Analog Output) Time Constant (Configuration Analog Output) Status of the Setpoints (Limits) (Configuration Relay Control) Mode of Operation of the Setpoints (Limits 1 and 2) (Configuration Limits) Relay Control (Configuration Relay Control) Selection of the Display Intervall (Settings Display Interval)117. Behaviour with activated Hold-Function (Acknowledge) Sensor System Power Communication with the PC138 MECHANICAL CONSTRUCTION / HOUSING149 CONNECTION DIAGRAMS1510 HARDWARE CONFIGURATION1611 MAINTENANCE / REPAIR1712 WARRANTY1713 DECLARATION OF CONFORMITY18 Operating Instructions T401 T402 JAQUET LTDstatus : 3/18 /1 Safety instructionsCertain components within the T401 T402 tachometers are only under dangerous voltages if the connectedcircuits have dangerous instruments comply with Protection Class I.

3 Hence it is mandatory to connect a protective earth on the PE-terminal. The instruments are designed and manufactured according to IEC-Publication 348 and they left theworks in perfect Operating Instructions contain information referring to risks, which must be strictly adhered to for safeoperation of the in a doubtful condition after electrical, climatic or mechanical overload must be immediatelydisconnected and returned to the manufacturer for Functional PurposeT400 tachometers measure and monitor frequencies (speed proportional values) within the range 0 to 35 000 HzThe family consists of the two types.

4 XT401 One channel frequency/current-converter with output 0 mA and switching limit with relay Article-No. 383Z-05307xT402 One channel frequency/voltage-converter with output 0 V and switching limit with relay Article-No. 383Z-053083 SpecificationsReference-conditions: ambient temperature + 20 C, power supply voltage within - T402 Lowest Measuring Range0 .. HzHighest Measuring Range0 .. kHzMeasuring range and setpoints are entered directly in physical units ( rpm) after the determination of theMachine Factor M = frequency (Hz) / measured value (rpm)Analog outputExecution T401 Current output0 .. 20 mA resp. 4 .. 20 mAselectable for rising or falling transfer functionMaximum Load 500 Ohm corresponding to a maximum of 10 VExecution T402 Voltage Output0.

5 10 V resp. 2 .. 10 Vselectable for rising or falling transfer functionMinimum Load 7 kOhm corresponding to a maximum of mAMaximum open-circuitVoltage :12 VResolution12 bit corresponding to 1 : 4096 Maximum Linearity %Accuracy % referred to the analog output end of range valueTime constantHardware 11 ms, software selectableTemperature 100 ppm/K, max. r 300 ppm/KOperating Instructions T401 T402 JAQUET LTDstatus : 4/18 /Response Time (stepresponse)The minimum measuring time is programmable as a Fix Time of 2 / 5 / 10 / 20 /50 / 100 / 200 / 500 ms / 1 / 2 / 5 For input frequencies with a period shorter than the Fix Time :maximum: 2* Fix Time + max.

6 Period of the input frequency + mstypical: Fix-Time + 1 period of the input frequency + ms- For input frequencies with a period longer than the Fix Time :Maximum:period of the input frequency + msRelayHysteresis of setpointsFor each limit an upper and a lower setpoint may be set independentlyRelay functionsMonostable change-over contacts relay, function individually selectable as normal or inverse and without or with acknowledge resp. hold via outputAC Load : max. 250 VAC, Load :Accuracy referred to the setpointTemperature 10 ppmTime delayThe minimum measuring time is programmable as a one period or a Fix-Time of2 / 5 / 10 / 20 / 50 / 100 / 200 / 500 ms 1 / 2 / 5 For input frequencies with a period shorter than the Fix Time, the delay time is :maximum: 2* Fix Time + max.

7 Period of the input frequency + mstypical: Fix-Time + 1 period of the input frequency + ms- For input frequencies with a period longer than the Fix Time, the delay time is :maximum: max. period of the input frequency + msOpen Collector outputExternal pull-up resistorR = U / , Ic nominal = 10mAVoltageU = 5 30 VInsulation1500 VACO perating Instructions T401 T402 JAQUET LTDstatus : 5/18 /Sensor input :Reference potential floating, galvanically separated from power supply and theoutputs, especially the current/voltage terminal for the cable shield is galvanically connected to the minus pole ofthe sensor resistance: 30 kOhmBuilt-in sensor power supply : +14 V , max.

8 35 mAshort-circuit proof, in case of activation of the protection, the circuit must beopened in order to rearm the Pull-up (+14 V) resistor 820 Ohmfor connection of two-wire transmitters, J1 must be set on position 2. (seechapter 10).Frequency range (-3dB): Hz / 35 kHzTrigger level : adaptive Trigger level, approximately Vin(peak) / 4, with minimum500 mV (factory configuration) and maximum value minimum value of the trigger level can be set down to 20 mV by movingstrap monitoringMonitoring of powered active sensors : 2- and 3-wire sensors (selection via strap1) with a current consumption < I min resp. > I max will be signalled defectiveaccording to behaviour description in chapter Sensor Failure.

9 MA < I min. < 25 mA < I max. < 25 mAThis supervision is activated, when active sensor type is of passive (electromagnetic/VR/Mag Pick-Up) sensors : open circuitstate of passive supervision is activated, when passive sensor type is monitoring functions can be switched off via the configuration trigger level depending on the input signal Frequency0,010,11101000,0010,010,1110100100010000100000 Frequency (Hz)Trigger level (Vpeak) Operating Instructions T401 T402 JAQUET LTDstatus : 6/18 /Binary inputFor external selection between two sets (A/B) of programmable relay controlsand acknowledge functions :No external pull up needed :active low : U < + (Relay control parameter set B )high (open) : U > + (Relay control parameter set A )Common reference potential with negative pole of sensor supplyThe simple method to activate the binary input is to short circuit the +Bin inputwith the sensor supply reference communication.

10 Serial interface similar to EIA RS 232, but with a +5V-CMOS level3-pole mm stereo headphone connector on front side,common reference potential with negative pole of sensor supplyPower supply T401 T40210 .. 36 VDC Power consumption max. 10 , 24 , 36V/3 Wmaximum allowable power supply interruption with16 V : 4 ms 24 V : 25 ms 36 V : 75 msClimatic conditionsKUE according to DIN 40 040 Operating temperature - 40 .. + 85 CStorage temperature - 40 .. + 90 Crelative humidity 75% average over a year, up to 90% for 30 days is to be avoidedInsulationGalvanic separation between : power supply, current output and the sensorpower supply.