Transcription of Operating Instructions - VEGASWING 63 - - two-wire
1 Operating InstructionsVibrating level switch with tube extension for liquidsVEGASWING 63- two-wireDocument ID: 292322 ContentsVEGASWING 63 - two-wire29232-EN-141015 Contents1 About this Function .. Target group .. Symbols For your Authorised personnel .. Appropriate use .. Warning about incorrect use .. General safety Instructions .. Safety label on the instrument .. CE conformity .. SIL conformity .. Safety Instructions for Ex areas .. Environmental Instructions ..63 Product Configuration .. Principle of Operation .. Storage and General Instructions .. Mounting Instructions ..125 Connecting to power Preparing the connection .. Connection procedure .. Wiring plan, single chamber Wiring plan - version IP 66/IP 68, 1 bar ..186 General information .. Adjustment elements.
2 Function chart .. Recurring test and function test (SIL, WHG) ..217 Maintenance and fault Maintenance .. Rectify faults .. Exchanging the electronics .. How to proceed if a repair is needed ..278 Dismounting Disposal ..289 Technical data .. Dimensions ..363 ContentsVEGASWING 63 - two-wire29232-EN-141015 Supplementary documentationInformation:Supplementary documents appropriate to the ordered version come with the delivery. You can find them listed in chapter "Product descrip-tion". Instructions manuals for accessories and replacement partsTip:To ensure reliable setup and operation of your VEGASWING 63, we offer accessories and replacement parts. The corresponding docu-mentations are: 30173 - Electronics module VEGASWING series 60 34296 - Protective cover 29750 - Lock fitting for VEGASWING 63 unpressurized 29751 - Lock fitting for VEGASWING 63 16 bar 29752 - Lock fitting for VEGASWING 63 64 barEditing status: 2014-10-0841 About this documentVEGASWING 63 - two-wire29232-EN-1410151 About this FunctionThis Operating Instructions manual provides all the information you need for mounting, connection and setup as well as important instruc-tions for maintenance and fault rectification.
3 Please read this informa-tion before putting the instrument into operation and keep this manual accessible in the immediate vicinity of the Target groupThis Operating Instructions manual is directed to trained specialist personnel. The contents of this manual should be made available to these personnel and put into practice by Symbols usedInformation, tip, noteThis symbol indicates helpful additional : If this warning is ignored, faults or malfunctions can : If this warning is ignored, injury to persons and/or serious damage to the instrument can : If this warning is ignored, serious injury to persons and/or destruction of the instrument can applicationsThis symbol indicates special Instructions for Ex applicationsThis symbol indicates Instructions for functional safety which must be taken into account particularly for safety-relevant applications.
4 ListThe dot set in front indicates a list with no implied sequence. ActionThis arrow indicates a single Sequence of actionsNumbers set in front indicate successive steps in a disposalThis symbol indicates special information about the disposal of bat-teries and For your safetyVEGASWING 63 - two-wire29232-EN-1410152 For your Authorised personnelAll operations described in this Operating Instructions manual must be carried out only by trained specialist personnel authorised by the plant work on and with the device the required personal protective equipment must always be Appropriate useThe VEGASWING 63 is a sensor for point level can find detailed information about the area of application in chapter "Product description".Operational reliability is ensured only if the instrument is properly used according to the specifications in the Operating Instructions manual as well as possible supplementary safety and warranty reasons, any invasive work on the device beyond that described in the Operating Instructions manual may be carried out only by personnel authorised by the manufacturer.
5 Arbi-trary conversions or modifications are explicitly Warning about incorrect useInappropriate or incorrect use of the instrument can give rise to application-specific hazards, vessel overfill or damage to system components through incorrect mounting or General safety instructionsThis is a state-of-the-art instrument complying with all prevailing regulations and guidelines. The instrument must only be operated in a technically flawless and reliable condition. The operator is responsible for the trouble-free operation of the the entire duration of use, the user is obliged to determine the compliance of the necessary occupational safety measures with the current valid rules and regulations and also take note of new safety Instructions in this Operating Instructions manual, the na-tional installation standards as well as the valid safety regulations and accident prevention rules must be observed by the safety and warranty reasons, any invasive work on the device beyond that described in the Operating Instructions manual may be carried out only by personnel authorised by the manufacturer.
6 Arbi-trary conversions or modifications are explicitly safety approval markings and safety tips on the device must also be For your safetyVEGASWING 63 - Safety label on the instrumentThe safety approval markings and safety tips on the device must be CE conformityThis device fulfills the legal requirements of the applicable EC guide-lines. By attaching the CE mark, VEGA provides a confirmation of successful testing. You can find the CE conformity declaration in the download area of " ". SIL conformityVEGASWING 63 fulfills the requirements of functional safety accord-ing to IEC 61508 resp. IEC 61511. You can find further information in the Safety Manual " VEGASWING series 60". Safety Instructions for Ex areasPlease note the Ex-specific safety information for installation and op-eration in Ex areas. These safety Instructions are part of the Operating Instructions manual and come with the Ex-approved Environmental instructionsProtection of the environment is one of our most important duties.
7 That is why we have introduced an environment management system with the goal of continuously improving company environmental pro-tection. The environment management system is certified according to DIN EN ISO help us fulfill this obligation by observing the environmental Instructions in this manual: Chapter "Packaging, transport and storage" Chapter "Disposal"73 Product descriptionVEGASWING 63 - two-wire29232-EN-1410153 Product ConfigurationThe scope of delivery encompasses: VEGASWING 63 point level switch Documentation this Operating Instructions manual Safety Manual "Functional safety (SIL)" (optional) Supplementary Instructions manual "Plug connector for level sensors" (optional) Ex-specific "Safety Instructions " (with Ex versions) if necessary, further certificatesThe VEGASWING 63 consists of the components: Housing lid Housing with electronics Process fitting with tuning fork123 Fig.
8 1: VEGASWING 63 with plastic housing1 Housing lid2 Housing with electronics3 Process fittingThe type label contains the most important data for identification and use of the instrument: Article number Serial number Technical data Article numbers, documentation SIL identification (with SIL rating ex works)Scope of deliveryConstituent partsType label83 Product descriptionVEGASWING 63 - two-wire29232-EN-141015 With the serial number, you can access the delivery data of the instru-ment via , "VEGA Tools" and "serial number search". You can find the serial number on the inside of the instrument as well as on the type label on the Principle of operationVEGASWING 63 is a point level sensor with tuning fork for point level is designed for industrial use in all areas of process technology and can be used in applications are overfill and dry run protection.
9 The small tuning fork allows use in all kinds of tanks and vessels. Thanks to its simple and rugged measuring system, VEGASWING 63 is virtually unaffected by the chemical and physical properties of the functions even under difficult conditions such as turbulence, air bub-bles, foam generation, buildup, strong external vibration or changing monitoringThe electronics module of VEGASWING 63 continuously monitors the following criteria via frequency evaluation: Strong corrosion or damage on the tuning fork Loss of vibration Line break to the piezo driveIf one of these faults is detected, the electronics signals it via a defined current to the signal conditioning instrument. The connection cable to the sensor is also monitored for line break and tuning fork is piezoelectrically energised and vibrates at its mechanical resonance frequency of approx.
10 1200 Hz. The piezos are fixed mechanically and are hence not subject to temperature shock limitations. The frequency changes when the tuning fork is covered by the medium. This change is detected by the integrated electronics module, transferred as a current value to the processing system and converted there into a switching on your requirements, VEGASWING 63 with two-wire electronics can be connected to different signal conditioning instru-ments. Compatible signal conditioning instruments are listed in chapter "Technical data".The data for power supply are specified in chapter "Technical data". OperationThe switching condition of VEGASWING 63 with plastic housing can be checked when the housing is closed (signal lamp). With the basic setting, products with a density g/cm ( lbs/in ) can be de-tected. The instrument can be adapted if products with lower density are to be areaFunctional principleVoltage supply93 Product descriptionVEGASWING 63 - two-wire29232-EN-141015On the electronics module you will find the following display and adjustment elements: Signal lamp for indication of the switching condition (green/red) DIL switch for adaptation to the product Storage and transportYour instrument was protected by packaging during transport.