Example: bankruptcy

Operating Manual - SUNNY ISLAND 4548-US / 6048-US

SI4548- 6048-US -BE-en-21 | Version ENGLISHOff-Grid InverterSUNNY ISLAND 4548-US / 6048-USOperating ManualSMA Solar Technology America LLCL egal ProvisionsOperating ManualSI4548- 6048-US -BE-en-213 Legal ProvisionsCopyright 2015 SMA Solar Technology America LLC. All rights part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, be it electronic, mechanical, photographic, magnetic or otherwise, without the prior written permission of SMA Solar Technology America Solar Technology America LLC doesn t make representations, express or implied, with respect to this documentation or any of the equipment and/or software it may describe, including (with no limitation) any implied warranties of utility, merchantability, or fitness for any particular purpose.

SMA Solar Technology America LLC Important Safety Instructions Operating Manual SI4548-6048-US-BE-en-21 5 Markings on this Product The following symbols are used as product markings with the following meanings.

Tags:

  Operating

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Operating Manual - SUNNY ISLAND 4548-US / 6048-US

1 SI4548- 6048-US -BE-en-21 | Version ENGLISHOff-Grid InverterSUNNY ISLAND 4548-US / 6048-USOperating ManualSMA Solar Technology America LLCL egal ProvisionsOperating ManualSI4548- 6048-US -BE-en-213 Legal ProvisionsCopyright 2015 SMA Solar Technology America LLC. All rights part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, be it electronic, mechanical, photographic, magnetic or otherwise, without the prior written permission of SMA Solar Technology America Solar Technology America LLC doesn t make representations, express or implied, with respect to this documentation or any of the equipment and/or software it may describe, including (with no limitation) any implied warranties of utility, merchantability, or fitness for any particular purpose.

2 All such warranties are expressly disclaimed. Neither SMA Solar Technology America LLC nor its distributors or dealers shall be liable for any indirect, incidental, or consequential damages under any circumstances.(The exclusion of implied warranties may not apply in all cases under some statutes, and thus the above exclusion may not apply.)Specifications are subject to change without notice. Every attempt has been made to make this document complete, accurate and up-to-date. Readers are cautioned, however, that SMA Solar Technology America LLC reserves the right to make changes without notice and shall not be responsible for any damages, including indirect, incidental or consequential damages, caused by reliance on the material presented, including, but not limited to, omissions, typographical errors, arithmetical errors or listing errors in the content trademarks are recognized even if these are not marked separately.

3 Missing designations do not mean that a product or brand is not a registered Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by SMA Solar Technology America LLC and SMA Solar Technology Canada Inc. is under is a registered trademark of Schneider Electric and is licensed by the Modbus Organization, and Pozidriv are registered trademarks of Phillips Screw is a registered trademark of Acument Global Technologies, Solar Technology America LLC3801 N. Havana StreetDenver, CO 80239 Safety InstructionsSMA Solar Technology America LLC4SI4548- 6048-US -BE-en-21 Operating ManualImportant Safety InstructionsSAVE THESE INSTRUCTIONSThis Manual contains important instructions for the following products: SUNNY ISLAND 4548-US / 6048-USThis Manual must be followed during installation and product is designed and tested in accordance with international safety requirements, but as with all electrical and electronic equipment, certain precautions must be observed when installing and/or Operating the product.

4 To reduce the risk of personal injury and to ensure the safe installation and operation of the product, you must carefully read and follow all instructions, cautions and warnings in this in this DocumentA warning describes a hazard to equipment or personnel. It calls attention to a procedure or practice, which, if not correctly performed or adhered to, could result in damage to or destruction of part or all of the SMA equipment and/or other equipment connected to the SMA equipment or personal symbols in this document In addition to the safety and hazard symbols described on the previous pages, the following symbol is also used in this Manual : SymbolDescriptionDANGER indicates a hazardous situation which, if not avoided, will result in death or serious indicates a hazardous situation which, if not avoided, could result in death or serious indicates a hazardous situation which, if not avoided, could result in minor or moderate is used to address practices not related to personal symbol accompanies notes that call attention to supplementary information that you must know and use to ensure optimal operation of the Solar Technology America LLCI mportant Safety InstructionsOperating ManualSI4548- 6048-US -BE-en-215 Markings on this ProductThe following symbols are used as product markings with the following regarding dangerous voltageThe product works with high voltages.

5 All work on the product must only be performed as described in the documentation of the arc hazardsThe product has large electrical potential differences between its conductors. Arc flashes can occur through air when high-voltage current flows. Do not work on the product during of hot surfaceThe product can become hot during operation. Do not touch the product during the Operating instructionsRead the documentation of the product before working on it. Follow all safety precautions and instructions as described in the is the standard applied by Underwriters Laboratories to the product to certify that it meets the requirements of the National Electrical Code , the Canadian Electrical Code CSA , IEEE 929 2000 and IEEE WarningsSMA Solar Technology America LLC6SI4548- 6048-US -BE-en-21 Operating ManualGeneral WarningsAll electrical installations must be made in accordance with the local and National Electrical Code ANSI/NFPA 70 or the Canadian Electrical Code CSA This document does not and is not intended to replace any local, state, provincial, federal or national laws, regulations or codes applicable to the installation and use of the product, including without limitation applicable electrical safety codes.

6 All installations must conform with the laws, regulations, codes and standards applicable in the jurisdiction of installation. SMA assumes no responsibility for the compliance or non-compliance with such laws or codes in connection with the installation of the product contains no user-serviceable parts. For all repair and maintenance, always return the unit to an authorized SMA Service installing or using the product, read all of the instructions, cautions, and warnings in this connecting the product to the electrical utility grid, contact the local utility company. This connection must be made only by qualified of the product must be made by qualified personnel Solar Technology America LLCT able of ContentsOperating ManualSI4548- 6048-US -BE-en-217 Table of Contents1 Information on this Document.

7 Validity.. Target Group.. Additional Information.. Terminology.. 152 SUNNY ISLAND 4548-US / 6048-US .. Properties.. At a Glance.. Scope of Delivery .. Required Tools and Materials .. Identifying the SUNNY ISLAND .. 253 Safety .. Intended Use .. Important Notes regarding Operation .. Potential Hazards .. 294 Mounting.. Selecting the Mounting Location .. Mounting the SUNNY ISLAND with the Wall Mounting Bracket .. Mounting the SUNNY ISLAND on a Stone Wall.. Mounting the SUNNY ISLAND using Wall Studs.. 365 Opening and Closing.. Opening the SUNNY ISLAND .. Closing the SUNNY ISLAND .. 386 Electrical Connection .. Grounding .. DC Connection .. Safety Precautions/Conditions.. Cable Dimensioning.. Cable Protection .. 46 Table of ContentsSMA Solar Technology America LLC8SI4548- 6048-US -BE-en-21 Operating Connecting the SUNNY ISLAND on the DC Side.

8 AC Connection .. Cable Protection .. AC1 (Loads/ SUNNY Boys) .. AC2 (Generator/Grid) .. Additional Connections .. Inserting the Data Cables.. Connecting the Data Cable of the Lithium-Ion Batteries.. Battery Temperature Sensor.. Battery Current Sensor.. Communication for Multi-Device Connection.. Multifunction Relay 1 and 2.. BatVtgOut Power Supply .. DigIn Digital Input .. Interface for External Communication .. Connection of the Interface for External Communication.. 627 Control Elements.. Display Messages .. DC Circuit Breaker.. Buttons.. Meaning of the Light-Emitting Diodes (LED).. SD Memory Card .. 688 Commissioning .. Requirements .. Starting the Quick Configuration Guide (QCG) .. Commissioning the battery current sensor.

9 739 Switching On and Off .. Switching On.. Stopping the SUNNY ISLAND (Standby) .. Switching Off.. Disconnecting the Device from Voltage Sources .. 76 SMA Solar Technology America LLCT able of ContentsOperating Recommissioning After Automatic Shutdown.. 7710 Operation .. Menu Structure .. Changing Parameters .. Direct Access - Direct Access to the Parameters .. Compact Meters .. Entering the Installer Password .. Display Messages (Overview) .. Parameter Display .. Display of Events .. Display of Warnings and Failures .. 9311 Data Storage on SD Memory Card .. Inserting the SD Memory Card .. Removing the SD Memory Card .. Saving and Loading Parameters .. Writing Log Data.. Status Messages .. Firmware Update.. 10012 Additional Functions.

10 Load Shedding .. Sleep Mode.. Time-Controlled Operation .. Overload and Short-Circuit Behavior.. Mixed Operation with SUNNY ISLAND Inverters of Different Power .. Device Faults and Autostart.. Automatic Frequency Synchronization .. Time-Controlled Standby .. Behavior in the Event of a Failure in a Three-Phase System.. 10713 Battery Management.. Battery Type and Minimum Battery Capacity .. 108 Table of ContentsSMA Solar Technology America LLC10SI4548- 6048-US -BE-en-21 Operating Battery Temperature .. Start Options .. State of Charge (SOC) and State of Health (SOH) .. Charge Control .. Boost Charge.. Full Charge .. Equalization Charge .. Manual Equalization Charge.. Silent Mode .. Battery-Preservation Mode .. Battery Diagnosis.. Battery Lead Resistance.


Related search queries