OPERATION AND SERVICE MANUAL - StanTronic

OPERATION AND SERVICE MANUALH ypotMAX MODEL 7705 (10 kV AC ONLY HIPOT)MODEL 7710 (12 kV DC ONLY HIPOT)MODEL 7715 (20 kV AC ONLY HIPOT)MODEL 7720 (20 kV DC ONLY HIPOT)SERIAL NUMBERM odel7705,10,15,20 Associated Research, Inc., 201213860 West Laurel DriveLake Forest, Illinois, Item 38672 Ver October 31, 2012 DECLARATION OF CONFORMITYM anufacturer:Associated Research, :13860 W. Laurel Forest, IL 60045 USAP roduct Name:7705/7710/7715/7720 Electrical SafetyComplianceAnalyzerModel Number:7705/7710/7715/7720 Conforms to the following Standards:Safety:EN 61010-1:2001EN 61010-031:2002 EMC:EN 61326:1997/A1:1998,(EN 55022:1998/A1:2000/A2:2003 Class A, EN 61000-3-2:2000, EN 61000-3-3:1995/A1:2001, IEC 61000-4-2:1995/A2:2000, IEC 61000-4-3:2002, IEC 61000-4-4:1995/A2:2001, IEC 61000-4-5:1995/A1:2000, IEC61000-4-6:1996/A1:2000, IEC 61000-4-8:1993/A1:2000,IEC 61000-4-11:1994/A1:2000)Supplementary InformationThe product herewith complies with the requirements of theLowVoltage Directive 73/23/EECas amended by 93/68/EEC and theEMCD irective 89/336/EEC a

operation and service manual hypotmax model 7705 (10 kv ac only hipot) model 7710 (12 kv dc only hipot) model 7715 (20 kv ac only hipot) model 7720 (20 kv dc only hipot)

Tags:

  Services, Manual, Operations, Operation and service manual

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of OPERATION AND SERVICE MANUAL - StanTronic

1 OPERATION AND SERVICE MANUALH ypotMAX MODEL 7705 (10 kV AC ONLY HIPOT)MODEL 7710 (12 kV DC ONLY HIPOT)MODEL 7715 (20 kV AC ONLY HIPOT)MODEL 7720 (20 kV DC ONLY HIPOT)SERIAL NUMBERM odel7705,10,15,20 Associated Research, Inc., 201213860 West Laurel DriveLake Forest, Illinois, Item 38672 Ver October 31, 2012 DECLARATION OF CONFORMITYM anufacturer:Associated Research, :13860 W. Laurel Forest, IL 60045 USAP roduct Name:7705/7710/7715/7720 Electrical SafetyComplianceAnalyzerModel Number:7705/7710/7715/7720 Conforms to the following Standards:Safety:EN 61010-1:2001EN 61010-031:2002 EMC:EN 61326:1997/A1:1998,(EN 55022:1998/A1:2000/A2:2003 Class A, EN 61000-3-2:2000, EN 61000-3-3:1995/A1:2001, IEC 61000-4-2:1995/A2:2000, IEC 61000-4-3:2002, IEC 61000-4-4:1995/A2:2001, IEC 61000-4-5:1995/A1:2000, IEC61000-4-6:1996/A1:2000, IEC 61000-4-8:1993/A1:2000,IEC 61000-4-11:1994/A1.)

2 2000)Supplementary InformationThe product herewith complies with the requirements of theLowVoltage Directive 73/23/EECas amended by 93/68/EEC and theEMCD irective 89/336/EEC as amended by 92/31 CE marking has been affixed on the device according to article 10of the EMC Directive 8/336 technical file and other documentation are on file withAssociated Research, GuerrieroVice President / General ManagerAssociated Research, Forest, Illinois USAS eptember 16, 2005iTABLE OF CONTENTS1. INTRODUCTION .. Warranty .. Safety Symbols .. Product Marking Symbols .. Caution and Warning Symbols .. Glossary of Terms .. Safety .. SERVICE and Maintenance .. Test Station .. Test Operator.

3 Key Features and Benefits .. 82. GETTING STARTED .. Unpacking and Inspection .. Packaging .. Contents of Carton .. Returning the Instrument for SERVICE or Calibration .. Installation .. Work Area .. Power Requirements .. Basic Connections .. Environmental Conditions .. 123. SPECIFICATIONS AND CONTROLS .. 7705 Functional Specifications .. 7710 Functional Specifications .. 7715 Functional Specifications .. 7720 Functional Specifications .. General Specifications .. Instrument Controls .. Front Panel Controls .. Rear Panel Controls .. 204. PROGRAMMING INSTRUCTIONS .. Power Up .. System Parameter Settings .. PLC Fail Stop .. LCD Contrast.

4 Alarm Smart GFI .. GPIB Address .. BUS Remote Command Set .. Memory Default System Parameters .. Default System Parameter Initialization .. LOCK/LOCAL Lock Function .. Local Function .. Password Setting .. Test Setup .. Memory Configuration .. Test Parameters .. Default Test Parameters .. Setting Up a Output Voltage setting .. HI-Limit Current setting .. LO-Limit Current setting .. Ramp UP Time setting .. Dwell Unit setting .. Dwell Time setting .. Ramp Down Time setting .. Frequency Selection (AC units only) .. Arc Detect and Arc Sensitivity Selection .. Ramp-HI selection (DC units only) .. Charge-LO setting (DC units only).

5 Connect .. 375. OPERATING INSTRUCTIONS .. Instrument Connections .. Settings Screen .. Performing a Test .. Discharge Function in DC units .. Connected Memory Indicator .. MANUAL Voltage Adjustment .. Reviewing Test Results .. Test Messages .. Additional Messages for DC units .. BUS Remote message .. Fatal Error .. Output Error .. 466. CONNECTION OF REMOTE I/O .. Signal Outputs on Remote I/O .. Signal Inputs of Remote I/O and Memory Access .. 487. BUS REMOTE INTERFACE USB / RS-232 / GPIB .. USB / RS-232 Interface .. RS-232 Connector .. Communications Port Configuration .. Sending and Receiving Commands .. GPIB Interface .. GPIB Connector.

6 GPIB Address .. Interface Functions .. / RS-232 / GPIB Interface Command List .. Rules for Sending Commands to the Test Execution Commands .. File Editing Commands .. Test Parameter Editing Commands and Companion System Parameter Editing Commands and Companion Query Commands .. IEEE Common Commands .. Status Reporting .. GPIB SERVICE Request .. Example of Communicating Over the GPIB Bus .. Non Volatile Memory .. BUS Remote message .. 638. OPTIONS .. 649. CALIBRATION .. Warranty Requirements .. Calibration Initialization .. Calibration Calibration of Hipot Voltage .. Calibration of 7705 AC Hipot Current .. Calibration of 7715 AC Hipot Current.

7 Calibration of 7710 DC Hipot Current .. Calibration of 7720 DC Hipot Current .. Calibration Complete Message .. 7710. REPLACEMENT PARTS LIST .. 7811. SCHEMATIC INDEX .. 80 Index is located at the back of the Warranty PoliciesAssociated Research, Inc., certifies that the instrument listed in this MANUAL meets orexceeds published manufacturing specifications. This instrument was calibrated usingstandards that are traceable to the National Institute of Standards and Technology(NIST).Your new instrument is warranted to be free from defects in workmanship and materialfor a period of (1) year from the date of shipment. You must complete the onlineregistration or call 1-800-858-TEST (8378) ext.

8 210 to register over the ProgramAssociated Research, Inc. recommends that your instrument be recertified on atwelve-month cycle. Instruments purchased and used in North America only mayhave their warranty extended in (1) year increments to a maximum of(5) Yearsprovided they are serviced by an Associated Research, Inc. technician. Therecertification and inspection must be performed annually following receipt of theinstrument. Any instrument not recertified and inspected annually will not be eligiblefor extended warranty status. This extended warranty is non-transferable and isoffered only to the original purchaser. A return material authorization (RMA) must beobtained from Associated Research, Inc.

9 Before returning this instrument for warrantyservice. Please contact our customer support center at 1-800-858-TEST (8378) toobtain an RMA number. It is important that the instrument is packed in its originalcontainer for safe transport. If the original container is not available or in poorcondition please contact our customer support center for proper instructions onpackaging. Damages sustained as a result of improper packaging will not behonored. Transportation costs for the return of the instrument for warranty servicemust be prepaid by the customer. Associated Research, Inc. will assume the returnfreight costs when returning the instrument to the customer. The return method will beat the discretion of Associated Research, ProgramA 3-Year warranty is also available for instruments purchased and used in NorthAmerica.

10 All costs for this warranty are paid with the initial purchase and includewarranty coverage, annual recertification and standard ground return freight for(3)Years. However, unlike our 5-Year program, annual recertification and inspection byAssociated Research, Inc. is not as provided herein, Associated Research, Inc. makes no warranties to thepurchaser of this instrument and all other warranties, express or implied (including,without limitation, merchantability or fitness for a particular purpose) are herebyexcluded, disclaimed and ModificationsAny non-authorized modifications, tampering or physical damage will void thiswarranty. Elimination of any connections in the earth grounding system or bypassingany safety systems will void this warranty.