operator s Manual132387 Rev. D, 2006-06 Analyzer 132387 Rev. B, 2004-10 operator s ManualAnalyzer132387 Rev. D, 2006-06 2003 Bayer HealthCare. All rights , Clinitek Status, Multistix, Multistix PRO, Combistix, Uristix,Labstix, Neostix, Clinitest and Chek-Stix are trademarks of and Cidex are trademarks of Johnson & is a trademark of Lafayette Pharmaceuticals, is a trademark of Linden is a trademark of Pats 5,408,535; 5,477,326; 5,877,863; 6,239,445; D456,082;D489,816 Origin: UKThe information in this Manual was correct at the time of , Bayer HealthCare continues to improve products and reservesthe right to change specifications, equipment, and maintenanceprocedures at any time without this instrument is used in a manner differently than specifiedin this Manual , the protection provided by the equipment maybe Diagnostics Mfg (Sudbury) LtdSudbury, CO10 2XQ, UKBayer HealthCare LLCS ubsidiary of Bayer Corporat

v A Brief Description 132387 Rev. D, 2006-06 What does the analyzer do? Your Clinitek Status® analyzer is a portable instrument for reading Bayer urinalysis strips and Clinitest®

Tags:

  Manual, Operator, Operator s manual, Strips, Urinalysis, Urinalysis strips

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Operator’s Manual - Block Scientific

1 operator s Manual132387 Rev. D, 2006-06 Analyzer 132387 Rev. B, 2004-10 operator s ManualAnalyzer132387 Rev. D, 2006-06 2003 Bayer HealthCare. All rights , Clinitek Status, Multistix, Multistix PRO, Combistix, Uristix,Labstix, Neostix, Clinitest and Chek-Stix are trademarks of and Cidex are trademarks of Johnson & is a trademark of Lafayette Pharmaceuticals, is a trademark of Linden is a trademark of Pats 5,408,535; 5,477,326; 5,877,863; 6,239,445; D456,082;D489,816 Origin: UKThe information in this Manual was correct at the time of , Bayer HealthCare continues to improve products and reservesthe right to change specifications, equipment, and maintenanceprocedures at any time without this instrument is used in a manner differently than specifiedin this Manual , the protection provided by the equipment maybe Diagnostics Mfg (Sudbury) LtdSudbury, CO10 2XQ, UKBayer HealthCare LLCS ubsidiary of Bayer CorporationTarrytown, NY 10591-5097 USAiii132387 Rev.

2 B, 2004-10 Table of ContentsA Brief Description .. vUnderstanding the Symbols and Display Icons .. vii1 Unpacking & Set Up .. 1-1 Unpacking .. 1-1 Set Up .. 1-2 Analyzer Set Up .. 1-2 Plugging Analyzer In .. 1-2 Installing Batteries .. 1-2 Inserting Test Strip Table .. 1-3 Loading Test Table Insert .. 1-3 Interfacing to a Computer .. 1-3 Analyzer Software Upgrades .. 1-4 Loading the Printer Paper or Label Roll .. 1-5 Warranty Registration .. 1-6 Powering Up .. 1-7 Powering Down .. 1-82 Interacting with the Touch Screen .. 2-1 Screens .. 2-1 Keyboards .. 2-43 Start-Up Wizard .. 3-14 Testing .. 4-1 Quick Tests .. 4-1 urinalysis Strip Test.

3 4-1 Cassette Test .. 4-6 Full Tests .. 4-11 urinalysis Strip Test .. 4-11 Cassette Test .. 4-19iv132387 Rev. D, 2006-065 Instrument Set Up .. 5-1 Instrument Set Up .. 5-1 Language Settings .. 5-2 Password .. 5-3 operator and Patient Information .. 5-4 Date and Time Settings .. 5-10 Test Sequence Number .. 5-12 Instrument Settings .. 5-13 Restore Default Settings .. 5-21 Diagnostics .. 5-22 System Information .. 5-236 Recall Results .. 6-1 Patient Results .. 6-1 Sending Data to a PC .. 6-37 Troubleshooting .. 7-1 List of Errors and Advisory Messages .. 7-4 Problem Checklist .. 7-88 Quality Control Testing .. 8-1 Information regarding CLIA Waiver.

4 8-29 Cleaning and .. 9-1 Changing Batteries .. 9-710 Appendices .. 10-1 Appendix A: Local Technical Support Providers andDistributors .. 10-1 Appendix B: Tables of Results .. 10-4 Appendix C: Specifications .. 10-10 Appendix D: Instrument Default Settings English .. 10-12 Appendix E: System Overview & Principles .. 10-14 Appendix F: CLIA Waiver Performance Characteristics 10-21 Appendix G: Training & Educational Materials .. 10-23 Appendix H: Safety Information .. 10-2411 Brief Description132387 Rev. D, 2006-06 What does the analyzer do?Your Clinitek Status analyzer isa portable instrument for readingBayer urinalysis strips and Clinitest immunoassay cassettes.

5 No specialtraining is needed to use thisinstrument. Several different Bayerurinalysis strips ( , Multistix 10SG) can be used with the analyzeras well as the Clinitest hCGPregnancy analyzer can be set up to beas simple or sophisticated as youprefer. You may simply insert adipped urinalysis strip or a Clinitestcassette into the analyzer and theresult will be reported (this is calleda Quick Test).Or, you have the option to enteran operator ID, Patient Name andPatient ID. This added informationwill be reported along with the testresults (this is called a Full Test).The touch screen displaysinstructions and prompts youthrough operation of the analyzer.

6 Inaddition, you enter informationthrough the touch I have to calibrate?You do not have to do anything tocalibrate. The instrument performsa system test each time it is turnedon. Then, each time a test is run,the instrument automaticallycalibrates. The white calibration bar(on the test table) provides NIST traceable does it work?Testing starts (in the Quick Testmode) when either the Strip Testor Cassette Test is selected on themain menu the Strip Test keyprompts you to adjust the test tableto accept a urinalysis strip. Thenyou touch the START key. Youhave 8 seconds to dip the test strip,blot the edge of the strip and placeit on the test strip table.

7 The table ispartially pulled into the instrumentfor calibration and then pulledcompletely into the instrument toread the test the Cassette Test keyprompts you to adjust the test tableto accept a cassette. Then youtouch the START key. You have8 seconds to draw the sample intoa pipette and dispense it into thesample well of the cassette. Theanalyzer automatically calibratesand then pulls the table completelyinto the instrument where thecassette is the Full Test mode for either aStrip Test or Cassette Test, youare prompted to enter an OperatorID, Patient Name and/or Patient IDprior to running a Brief DescriptionviA Brief Description132387 Rev.

8 D, 2006-06 How do I get results?Results will be displayed on thetouch screen and printed (ifdesired). The results can also betransferred to a computer using a9-pin null modem serial cable andthe RS-232 serial port on the backof the analyzer stores results from200 patient tests. You are able torecall past patient test results onthe analyzer using the RecallResults is the analyzer powered?The analyzer can be pluggedinto an electrical outlet for use onthe bench top, or it can be poweredby batteries and freely moved fromone testing site to another. Thebatteries fit into an opening on thebottom of the about this operator sManual?

9 The operator s Manual containsthe directions you need to unpackthe analyzer, use it for your dailyBayer urinalysis and Clinitestimmunoassay testing and keep it ingood working you read through theOperator s Manual , you will findthese symbols:In the operator s Manual , you willnotice some text is in bold/italic text identifies screen names. NOTES: contain useful tipson using the analyzer. Notesappear in italicized text identifies a button(touch sensitive area) on thescreen. CAUTION: should befollowed carefully to ensure youranalyzer operates correctly andis not damaged. Cautionsappear in bold the Symbols and Display Icons132387 Rev.

10 D, 2006-06 Instrument and Labeling SymbolsThis section describes the symbols that appear on the exterior of theClinitek Status instrument, the power supply provided with the instrument,the carton in which the instrument was delivered and the supplies of reagentstrips and cassettes which you will use with the that the input supply is direct currentIdentifies that the instrument is type B equipment, whichprovides a particular degree of protection against electric shockIdentifies that the instrument is class 1 type equipment, whichhas basic insulation and additional safety grounding precautionsDouble insulated product or transformer may also identifyclass 2 equipment (power supply only)


Related search queries