1 user S MANUALAIR-CONDITIONERRKW012A412 DSRK63ZM-SSRK71ZM-SSRK80ZM-SAIR-CONDITIO NING & REFRIGERATION DIVISION3-1, Asahi, Nishibiwajima-cho, Kiyosu, Aichi, 452-8561, HEAVY INDUSTRIES AIR-CONDITIONING EUROPE, Roundwood Avenue, Stockley Park, Uxbridge, Middlesex, UB11 1AX, United KingdomTel: +44-20-7025-2750 Fax: +44-20-7025-2751 HEAVY INDUSTRIES AIR-CONDITIONERS AUSTRALIA, PTY. Commercial Road Kingsgrove NSW 2208 PO BOX 318 Kingsgrove NSW 1480 Tel: +61-2-8571-7977 Fax: +61-2-8571-7992 INSTRUCTIONSMANUEL DE L UTILISATEURCLIMATISEURANWENDERHANDBUCHKL IMAGERA TISTRUZIONI PER L USOCONDIZIONATORE D ARIAMANUAL DEL PROPIETARIOACONDICIONADOR DE AIREGEBRUIKERSHANDLEIDINGAIRCONDITIONING MANUAL DO UTILIZADORAPARELHO DE AR CONDICIONADOРУКОВОДСТВО ПО ЭКСПЛУАТАЦИИКОНДИЦИОНЕР ВОЗДУХАKULLANIM KILAVUZUENGLISHDEUTSCHITALIANOESPAN OLNEDERLANDSPORTUGU SРУССКИЙT RK EFRAN AIS This air conditioner complies with EMC Directive 2004/108/EC,LV Directive 2006/95 climatiseur est conforme la Directive EMC: 2004/108/EC, LVDirective 2006/95 Kimager t erf llt die EMC Direktiven 2004/108/EC, LVDirektiven 2006/95 condizionatore d aria conforme alla Direttiva EMC.
2 2004/108/EC, LV Direttiva 2006/95 airconditioner voldoet aan EMC Directive 2004/108/EC, LVDirective 2006/95 acondicionador de aire cumple con la directiva EMC: 2004/108/EC, LV Directiva 2006/95 aparelho de ar condicionado est em conformidade com aDirectiva EMC 2004/108/EC e a Directiva LV 2006/95/EC. fi fi EMC 2004/108/EK LV 2006/95 ,44/18/14, 11:001 1 Thank you for purchasing a MITSUBISHI HEAVY INDUSTRIES, LTD. Air-Conditioner. Toget the best long-lasting performance, please read and follow this user s MANUAL carefullybefore using your air-conditioner. After reading, please store the MANUAL in a safe placeand refer to it for operational questions or in the event of any air-conditioner is intended for domestic not vent R410A into the atmosphere: R410A is a fluorinated greenhouse gas,covered by the Kyoto Protocol with a Global Warming Potential (GWP) = Air Conditioning product may be marked with this symbol.
3 It meansthat waste electrical and electronic equipment (WEEE as in directive 2012/19/EU) should not be mixed with general household waste. Air conditionersshould be treated at an authorized treatment facility for re-use, recyclingand recovery and not be disposed of in the municipal waste stream. Pleasecontact the installer or local authority for more symbol printed in the batteries attached to your Air Conditioningproduct is information for end-users according to the EU directive 2013/56/EU article 20 annex , at their end-of-life, should be disposed of separately from generalhousehold waste. If a chemical symbol is printed beneath the symbolshown above, this chemical symbol means that the batteries contain aheavy metal at a certain concentration. This will be indicated as follows:Hg:mercury( ) , Cd:cadmium( ) , Pb:lead( )Please, dispose of batteries correctly at your local community wastecollection or the recycling 2 Name of each part and its function.
4 6 Remote control 8 Operation failure with the remote control .. 8 Temporary run 8 Installing two air conditioners in the sameroom .. 9 Child 9 Operation and display section forremote 10 Current time 11 AUTO mode 11 Temperature adjustment during AUTO .. 12 FAN 12 COOL/HEAT/DRY/FAN mode operation .. 13 Air-conditioner operabletemperature 13 Characteristics of HEAT mode operation .. 13 Airflow direction 143D AUTO 14 SLEEP TIMER 15 The emission sound pressure level from each Indoor and Outdoor unit is under 70 dB(A).OFF-TIMER 15ON-TIMER 16 SLEEP TIMER + ON-TIMER operation .. 16ON-TIMER + OFF-TIMER operation .. 17 ALLERGEN CLEAR 17 WEEKLY TIMER 18 HIGH POWER/ECONOMY operation .. 22 NIGHT SETBACK 23 SILENT 23 SELF CLEAN 24 Auto restart 24 Tips for effective operation ..24 Installation location 26 Proper 28 Notice ..29 Contact your 30 About the Multiple 30 Self diagnosis 31 RKW012A412D_EN_001-0327/22/14, 10:201 2 Safety precautions Before starting to use the system, please read these Safety precautions carefully to ensureproper operation of the system.
5 When you have read this instruction MANUAL , please keep it without missing. If someone elsetakes over as operator , make certain that the MANUAL is also passed on to the new operator . INSTALLATION PRECAUTIONS The system is for domestic, residential etc. used in severer environments, such as an engineering workplace, the equipmentmay function observe these precautions with great care, since they are essential to your safety. Symbols which appear frequently in the text have the following meaning:WARNINGCAUTIONI mproper handling could lead to drastic result like death, se-rious injury, pose a serious problem, depending on the prohibitedProvide proper earth-ingObserve instructionswith great care The system must be installed by your dealer or a qualified is not advisable to install the system by yourself, as faulty handling may cause leak-age of water, electric shock or fire.
6 Do not install it where flammable gas may leaks may cause fire. Depending on the place of installa-tion, an earth leakage breaker may you do not install an earth leakagebreaker, you may get an electric shock. Make sure to install the drain hoseproperly so that all the water isdrained installation may lead to waterdrop in the room resulting in wet furni-ture. Make sure that the system has been properly cables should never be connected to a gas pipe, water pipe, lightning conductoror telephone earth cable. Incorrect installation of the earth cable may produce an elec-tric , 13:552 3 OPERATION PRECAUTIONSWARNINGCAUTION Cleaning and user maintenance shallnot be made by children without su-pervision. Do not insert anything into the air may cause injury, as the internal fanrotates at high speed. This appliance can be used by children aged from 8 years and above and personswith reduced physical, sensory or mental capabilities or lack of experience andknowledge if they have been given supervision or instruction concerning use ofthe appliance in a safe way and understand the hazards involved.
7 Store the remote control out of reach of to observe this may result in the batteries being swallowed or other accidents. Only use approved of steel or copper wire instead of anapproved fuse is strictly prohibited, as itmay cause a breakdown or fire. Do not handle the switches with may cause an electric shock. Do not swing from the indoor the indoor unit falls down,you may getinjured. Do not place a flammable insecticideor paint spray near the blower, norspray it directly on the may result in a fire. You should not expose any combus-tion appliance directly to the airstream of the appliance may then work inad-equately. Do not wash the air-conditioner could cause an electric shock. Children shall not play with the appli-ance. Do not expose yourself to the coolingair for a long could affect your physical conditionand cause health problems.
8 Safety precautions The system should only be used forits ORIGINAL purpose and not for any-thing else like, for instance, preserva-tion of food, plants or animals, preci-sion devices or works of system is only intended for use inordinary domestic rooms. Any other useof the system may damage the qualityof food, etc. Do not place anything containing wa-ter, like vases, on top of the entering the unit could damagethe insulation and therefore cause anelectric shock. Do not install the system where theairflow direction is aimed directly atplants or will damage their health. Do not sit on the outdoor unit nor putanything on the unit falls down or things drop off it,people could get hurt. After a long period of use, check theunit's support structure from time you do not repair any damage rightaway, the unit may fall down and causepersonal , 13:553 4 Safety precautionsCAUTION Do not touch the aluminum fins on theair heat may result in injury.
9 Do not place household electricalappliances or household items underneath the indoor or outdoor falling from the unit maystain objects and cause accidents orelectrical shock. Do not operate the system withoutthe air can cause malfunction of the systemdue to clogging of the heat exchanger. Do not shut off the power supply im-mediately after stopping the at least 5 minutes, otherwise thereis a risk of water leakage or breakdown. Do not control the system with mainpower can cause fire or water leakage. Inaddition, the fan can start unexpectedly,which can cause personal injury. Do not pour liquid into this unit and donot put water container on this entering the unit could damagethe insulation and therefore cause anelectric shock. If you operate the system togetherwith a combustion appliance, youmust regularly ventilate the ventilation may cause acci-dents due to oxygen deficiency.
10 Stand firmly on a stepladder or otherstable object when removing the inletpanel and to observe this may result ininjury through insecure objects topplingover. When you clean the system, stop theunit and turn off the power open the panel while the internalfan is rotating. Do not place objects near the out-door unit or allow leaves to gatheraround the there are objects or leaves around theoutdoor unit, small animals may enterunit and contact electrical parts andmay cause a break-down, smoke or fire. Contact your dealer to clean insidethe indoor unit, do not attempt to doby use of a non-approved detergent orimproper washing method may damagethe unit s plastic components and causeleaks. Damage, smoke, or fire may alsohappen if the detergent comes in con-tact with electrical parts or the unit smotor. Stop the unit and turn off the power ifyou hear thunder or there is a dangerof may damage the unit.