Example: biology

OWNER'S MANUAL - Trane

OWNER'S MANUAL . MINI TVR 5G. Thank you very much for purchasing our air conditioner, Before using your air conditioner, please read this MANUAL carefully and keep it for future reference. 2. 4. 1. 3. 1 air outlet 3 Fix leg 2 air inlet 4 Refrigerant piping connection part (connection part in side ). NOTE. All the pictures in this MANUAL are for explanation purpose only. They may be slightly different from the air conditioner you purchased(depend on model). The actual shape shall prevail. 16kW complying with IEC 61000-3-12. Do not insert fingers, rods or other objects into the air inlet or outlet. CONTENTS PAGE When the fan is rotating at high speed, it will cause injury. Never use a flammable spray such as hair spray, IMPORTANT SAFETY lacqueror paint near the unit. It may cause a fire.

Fix leg Refrigerant piping connection part (connection part in side) air inlet air outlet Fig.1 All the pictures in this manual are for explanation purpose only.

Tags:

  Manual, Owner s manual, Owner, Trane, Side

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of OWNER'S MANUAL - Trane

1 OWNER'S MANUAL . MINI TVR 5G. Thank you very much for purchasing our air conditioner, Before using your air conditioner, please read this MANUAL carefully and keep it for future reference. 2. 4. 1. 3. 1 air outlet 3 Fix leg 2 air inlet 4 Refrigerant piping connection part (connection part in side ). NOTE. All the pictures in this MANUAL are for explanation purpose only. They may be slightly different from the air conditioner you purchased(depend on model). The actual shape shall prevail. 16kW complying with IEC 61000-3-12. Do not insert fingers, rods or other objects into the air inlet or outlet. CONTENTS PAGE When the fan is rotating at high speed, it will cause injury. Never use a flammable spray such as hair spray, IMPORTANT SAFETY lacqueror paint near the unit. It may cause a fire.

2 PARTS OPERATION Never touch the air outlet or the horizontal blades while the swing flap is in operation. OPERATION AND Fingers may become caught or the unit may break down. MALFUNCTION CODE OF OUTDOOR Never put any objects into the air inlet or outlet. FOLLOWING SYMPTOMS ARE NOT AIR CONDITIONER Objects touching the fan at high speed can be dangerous. Never inspect or service the unit by yourself. Ask a qualified service person to perform this work. Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. 1. IMPORTANT SAFETY INFORMATION Contact you local government for information regarding the To prevent injury to the user or other people and property connection systems available.

3 Damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or If electrical appliances are disposed of in landfills or damage. dumps, hazardous substances can leak into the groundeater and get into the food chain, damaging your The safty precautions listed here are divided into two categories. In health and well-being. either case, important safty information is listed which must be read carefully. To prevent refrigerant leak, contact your dealer. When the system is installed and runs in a small room, it is WARNING required to keep the concentration of the refrigerant, if by any chance coming out, below the limit. Otherwise, oxygen in the Failure to observe a warning may result in death. The room may be affected, resulting in a serious accident.

4 Appliance shall be installed in accordance with national wiring regulations. The refrigerant in the air conditioner is safe and normally CAUTION does not leak. If the refrigerant leaks in the room, contact with a fire of a Failure to observe a caution may result in injury or damage burner, a heater or a cooker may result in a harmful gas. to the equipment. Turn off any combustible heating devices, ventilate the room, and contact the dealer where you purchased the unit. WARNING Do not use the air conditioner until a service person confirms that the portion where the refrigerant leaks is repaired. Ask your dealer for installation of the air conditioner. Incomplete installation performed by yourself may result in a water leakage, electric shock, and fire. Ask your dealer for improvement, repair, and CAUTION.

5 Maintenance. Do not use the air conditioner for other purposes. Incomplete improvement, repair, and maintenance may result In order to avoid any quality deterioration, do not use the unit in a water leakage, electric shock, and fire. for cooling precision instruments, food, plants, animals or works of art. In order to avoid electric shock, fire or injury, or if you detect any abnormality such as smell of fire, turn off the Before cleaning, be sure to stop the operation, turn the power supply and call your dealer for instructions. breaker off or pull out the supply cord. Otherwise, an electric shock and injury may result. Never let the indoor unit or the remote controller get wet. It may cause an electric shock or a fire. In order to avoid electric shock or fire, make sure that an earth leak detector is installed.

6 Never press the button of the remote controller with a hard, pointed object. Be sure the air conditioner is grounded. The remote controller may be damaged. In order to avoid electric shock, make sure that the unit is grounded and that the earth wire is not connected to gas or Never replace a fuse with that of wrong rated current or water pipe, lightning conductor or telephone earth wire. other wires when a fuse blows out. Use of wire or copper wire may cause the unit to break down In order to avoid injury, do not remove the fan guard of or cause a fire. the outdoor unit. It is not good for your health to expose your body to the Do not operate the air conditioner with a wet hand. air flow for a long time. An electric shock may happen. OWNER'S MANUAL 1. Do not touch the heat exchanger fins.

7 These fins are sharp and could result in cutting injuries. 2. PARTS NAMES. The air conditioner consists of the indoor unit, the Do not place items which might be damaged by moisture outdoor unit, the connecting pipe and the remote under the indoor unit. controller. (see ). Condensation may form if the humidity is above 80%, the drain outlet is blocked or the filter is polluted. Force Cooling Control Force cooling After a long use, check the unit stand and fitting for control Button sw1 Display control button sw2. damage. If damaged, the unit may fall and result in injury. To avoid oxygen deficiency, ventilate the room sw1. sufficiently if equipment with burner is used together with the air conditioner. sw2. Arrange the drain hose to ensure smooth drainage. MAIN BOARD. Incomplete drainage may cause wetting of the building, furniture etc.

8 (OUTDOOR UNIT). Never touch the internal parts of the controller. Force Cooling Control Do not remove the front panel. Some parts inside are Force cooling control of outdoor unit be pressed once that a order dangerous to touch, and a machine trouble may happen. to force cooling in indoor unit. When the frequence of outdoor unit change to 44Hz and then running it; indoor fan run in high speed. Never expose little children, plants or animals directly to Press the button again will exit the Force Cooling Control. the air flow. Adverse influence to little children, animals and plants may Display function result. Th e f u n c t i o n o f t e x t r u n c i r c u l a t e a s f o w l l i n g(12/14/16KW . Do not allow a child to mount on the outdoor unit or Normal display Display -- . avoid placing any object on it.)

9 Falling or tumbling may result in injury. Operating mode The last fault or protection (0 Stanby; 2 Cooling; code (if there is no fault or Do not operate the air conditioner when using a room 3 Heating; 4 Forced protection code it will be fumigation - type insecticide. cooling display nn ). Failure to observe could cause the chemicals to become . deposited in the unit, which could endanger the health of Operating fan speed grade The quantities of the operating (0 Power off) interior units those who are hypersensitive to chemicals.. The total capacity Total quantities of the interior Do not place appliances which produce open fire in requirements of the units . places exposed to the air flow from the unit or under the interior unit indoor unit.. The capacity requirements T2 average temperature.)

10 It may cause incomplete combuston or deformation of the unit due to the heat. of the revised external unit Actual voltage AD value .. T3 piping temperature Actual current value Do not install the air conditioner at any place where .. flammable gas may leak out. T4 environmert temperature PMV opening . If the gas leaks out and stays around the air conditioner, a fire . may break out. T5 discharge temperature The surface temperature of (actual) (if it is over one the cooling fin The appliance is not intended for use by young children hundred, it will be only or infirm persons without supervision. display the hundreds place and the tens place). Young children should be supervised to ensure that they do not play with the appliance. When capacity of indoor unit greater than the sum of 100%, capacity of indoor unit will be attenuated.