Example: confidence

P70, P72, and P170 Series Controls for Dual Pressure ...

The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls Controls , Inc. shall not be liable for damages resulting from misapplication or misuse of its products. 2015 Johnson Controls , P70, P72, and P170 Series Controls for dual Pressure ApplicationsDescriptionThe P70, P72, and P170 Controls for dual Pressure Applications are designed primarily for use as combination high and low Pressure Controls on commercial refrigeration and air conditioning Controls are available in several Pressure ranges and are compatible with most common refrigerants.

The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office.

Tags:

  Dual

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of P70, P72, and P170 Series Controls for Dual Pressure ...

1 The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls Controls , Inc. shall not be liable for damages resulting from misapplication or misuse of its products. 2015 Johnson Controls , P70, P72, and P170 Series Controls for dual Pressure ApplicationsDescriptionThe P70, P72, and P170 Controls for dual Pressure Applications are designed primarily for use as combination high and low Pressure Controls on commercial refrigeration and air conditioning Controls are available in several Pressure ranges and are compatible with most common refrigerants.

2 Ammonia compatible models are also Controls respond directly to system Pressure changes on both high and low sides, and can provide single-device control of the are available in several different electrical ratings and switch configurations, including independent high and low Pressure switches (on P70S and P170S models). The P72 models provide direct control of 208 to 240 volt, single-phase motors up to three horsepower, and 208 to 220 volt, three-phase motors up to five to the P70, P72, and P170 Series Controls for dual Pressure Applications Product Bulletin (LIT-125455) for important product application all-steel case and cover built to provide long lasting, rugged protection for internal components sight-set calibrated Pressure adjustment displays a visible Pressure scale, fully adjustable through the range without removing the cover (on NEMA 1 enclosure models)

3 MICRO-SET differential option allows for precise control on low Pressure applications independent high and low Pressure switches (P70S and P170S Models) satisfies a variety of dual Pressure application wiring requirements with a single versatile control convertible high Pressure reset auto reset or manual reset lockout (P70S and P170S Models) reduces inventory one control can be adapted to several dual Pressure applications in the fieldApplications P70S and P170S models have independently operated high and low Pressure single-pole, double-throw (SPDT) switches that can be wired to satisfy a variety of control requirements. These adaptable Controls also come with a high Pressure manual reset lockout mechanism that may be converted to automatic reset.

4 P70L, M, N, and P170L, M, N models have a single-pole, single-throw (SPST) switch. Models are available with automatic or manual reset lockout options. Models with manual reset are available with either high-side-only manual reset, or low-side and high-side manual reset. Ammonia-compatible models are also available (P70L and P70M only). P72 models have a double-pole, single-throw (DPST) switch with load-carrying contacts that can provide direct control of 208 to 240 VAC, single-phase motors up to 3 hp, and 208 to 220 VAC, three-phase motors up to 5 hp. See the DPST Electrical Ratings (P72L, M, and N Types) that models are available with Limited Knob Adjustment, which restricts adjustment of the Pressure settings and deters over-adjustment or tampering.

5 NEMA 1 enclosures are standard on most models. NEMA 3R enclosures are also InformationIf the P70, P72, and P170 Series Controls for dual Pressure Applications fail to operate within its specifications, replace the unit. For a replacement control, contact the nearest Johnson Controls Chart (Part 1 of 2)Product Code NumberSwitchActionLow Pressure Side psi (kPa)High Pressure Side psi (kPa)PressureConnectorLimited Knob AdjustmentRangeDifferentialRangeDifferen tial (Non-Adjustable)MICRO-SET Controls for Non-Corrosive RefrigerantsP70LB-6C1 SPST12 to 80(-41 to 552)Minimum 5 (34)Maximum 35 (241)100 to 500(690 to 3,447)Fixed approx. 65 (448)36 in. capillary with 1/4 in.

6 Flare nutLow cut-outP70MA-1C1 Lockout requires manual resetNoneP70SA-1C1 Two independent SPDTF ixed at 65 (448) orLockout requires manual resetP170LB-6C1 SPSTF ixed approx. 65 (448)1/4 in. external flare connectorLow cut-outP170MA-18C1 Lockout requires manual resetNoneP170SA-1C1 Two independent SPDTF ixed at 65 (448) orLockout requires manual resetAll Range Controls for Non-Corrosive RefrigerantsP70LB-1C1 SPST20 to 100(-68 to 690)Minimum 6 (41)Maximum 50 (345)100 to 500(690 to 3,447)Fixed Approx. 65 (448)36 in. capillary with 1/4 in. flare nutLow cut-outP70MA-1C1 Lockout Requires Manual ResetNoneP70NA-1 CFixed (manual reset)P72LA-1C1 DPSTM inimum 7 (48)Maximum 50 (345)Fixed approx.

7 65 (448)P72LB-1C1 Low cut-outP72MA-1C1 Lockout requires manual resetNoneP72NA-1C1 Fixed (manual reset)P70MA-1 dual Pressure ControlCode No. LIT-1900172 Issued November 13, 2015 The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls Controls , Inc. shall not be liable for damages resulting from misapplication or misuse of its products. 2015 Johnson Controls , , P72, and P170 Series Controls for dual Pressure Applications (Continued) Note: For information on models not listed, please contact Johnson Controls /PENN Refrigeration Application Engineering at Specifications All Range Controls for Non-Corrosive RefrigerantsP170LB-1C1 SPST20 to 100(-68 to 690)Minimum 7 (48)Maximum 50 (345)100 to 500(690 to 3,447)Fixed approx.

8 65 (448)1/4 in. External flare connectorLow cut-outP170MA-1C1 Lockout requires manual resetNoneP170NA-1 CFixed (manual reset)All Range Ammonia Compatible ControlsP70LA-2C1 SPST20 in. Hg to 100(-68 to 690)Minimum 7 (48)Maximum 50 (345)100 to 500(690 to 3,447)Fixed approx. 65 (448)1/4 in. Internal NPT connectorNoneP70MA-2C1 Lockout requires manual reset1. Control models with high Pressure side (only) that are UL Listed as Refrigeration Pressure Limiting PressuresPressureLow SideHigh SideAll RangeMICRO-SETM aximum Working Pressure100 psi (552 kPa)80 psi (690 kPa)500 psi (3,447 kPa)Maximum Overpressure325 psi (2,241 kPa)525 psi (3,620 kPa)525 psi (3,620 kPa)Selection Chart (Part 2 of 2)Product Code NumberSwitchActionLow Pressure Side psi (kPa)High Pressure Side psi (kPa)PressureConnectorLimited Knob AdjustmentRangeDifferentialRangeDifferen tial (Non-Adjustable)

9 M1L1L2 LoadLowHighLow side opens Lineto M1 on Pressure side opens Lineto M1 on Pressure Wiring for SPST Switch (P70L, M, and N, and P170L, M, and N Models) Wiring for Four-Wire, Two-Circuit Switch (P70P, Q and R Models)High side opens Maincircuit (Line to M2),and closes auxiliarycircuit (Line to M1)on Pressure rise. Alarm CircuitPowerLow side opens Maincircuit (Line to M2),and closes auxiliarycircuit (Line to M1)on Pressure L1L2 LowHighLoadLineLineM1M2 Low side opens Line to M1 andLine to M2 on Pressure side opensLine to M1 andLine to M2 onpressure **(L3 is third supply line in 3-phase applications.) Wiring for DPST Switch (P72L,M,and N Models) 123L1L2 HighAlarmLoadLowAlarm132 HighLowHigh side switch opens1 to 2 and closes 1 to 3on Pressure side switch opens1 to 2 and closes 1 to 3on Pressure SPDT Switches Wired as a dual Pressure Control (Switching a Single Load with Optional High Side Alarm and Low Side Alarm) (P70S and P170S Models) 123L1L2 HighLoadHighAlarmLowLoadLowAlarm132 HighLowHigh side switch opens1 to 2 and closes 1 to 3on Pressure side switch opens1 to 2 and closes 1 to 3on Pressure SPDT Switches Wired to Control Two Different Loads (Optional High Side Alarm and Low Side Alarm) (P70S and P170S Models)

10 The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls Controls , Inc. shall not be liable for damages resulting from misapplication or misuse of its products. 2015 Johnson Controls , , P72, and P170 Series Controls for dual Pressure Applications (Continued) 2-1/16 DiameterMounting HoleTwo Mounting Holes10-32 UNF-28 Thread5(127)5/16(8)5/16(9)1(25)1-1/8(29) 1-15/16(48)15/16(95)11/16(17)3-1/4(83)13 /16(20)1-3/4(44)1-11/16(43)15/16(95)5-11 /16(144)3-3/16(80)3(76)1-5/16(33)1 5/16(33)15/16(24)1/16(2)3/16(4)(53)11/16 (18)3/16(5)5/16(8)1-11/16(43)5/16(15)2-7 /8(73)Reset Button for Controlswith both High and LowSide ResetReset Lever for Controlswith High Side Only Manual Reset(Except P70S and P170S Models)3/16(5)3/8(10)X3/16(5)DiameterMou nting Hole7/8(22)(1/2 in.)


Related search queries