Example: stock market

Packaged Rooftop Air Conditioners - Trane

Packaged Rooftop Air Conditioners IntelliPak Rooftops with Evaporative-Cooled Condensers 24 - 116 Tons 60 Hz June 2006 RT-PRC018-EN. Introduction IntelliPak Rooftops with Evaporative-Cooled Condensers Why Choose IntelliPak with Evaporative- OnlyTrane offers its years of experience, Cooled Condenser? along with a tradition for technology and For building owners and tenants the cost innovation, to bring total comfort to of energy for air conditioning may be every building specially their single, largest annual operating designed IntelliPak Rooftop with expense. Businesses continually seek evaporative-cooled condenser is a part energy efficient technologies that of that tradition.

Packaged Rooftop Air Conditioners IntelliPak™ Rooftops with Evaporative-Cooled Condensers 24 - 116 Tons — 60 Hz June 2006 RT-PRC018-EN

Tags:

  Trane, Conditioners, Packaged, Rooftop, Packaged rooftop air conditioners

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Packaged Rooftop Air Conditioners - Trane

1 Packaged Rooftop Air Conditioners IntelliPak Rooftops with Evaporative-Cooled Condensers 24 - 116 Tons 60 Hz June 2006 RT-PRC018-EN. Introduction IntelliPak Rooftops with Evaporative-Cooled Condensers Why Choose IntelliPak with Evaporative- OnlyTrane offers its years of experience, Cooled Condenser? along with a tradition for technology and For building owners and tenants the cost innovation, to bring total comfort to of energy for air conditioning may be every building specially their single, largest annual operating designed IntelliPak Rooftop with expense. Businesses continually seek evaporative-cooled condenser is a part energy efficient technologies that of that tradition.

2 Provide relief from these rising costs. Trane 's legacy for quality products and In many applications, the energy saving reliable performance carries through benefits of evaporative-cooled with this energy efficient solution for condensing reduces annual operating today's building systems. costs significantly enough to provide short-term payback on the initial investment. After the payback, it's all savings. Reduced operating expense and worry- free comfort has convinced many building owners that Packaged Rooftop equipment with evaporative-cooled condensing is the right choice for their buildings. 2003 American Standard All rights reserved RT-PRC018-EN.

3 Contents Introduction 2. Features and Benefits 4. Application Considerations 6. Selection Procedure 7. Model Number Description 7. General Data 8. Performance Data 14. Controls 18. Electric Power 19. Dimension and Weights 20. Mechanical Specifications 21. RT-PRC018-EN 3. Features and Benefits This catalog contains information density, UV resistant, molded plastic relating to IntelliPak evaporative-cooled housing. condensers. For expanded details on Refrigerant gas enters each coil set IntelliPak rooftops, please see the where a three-dimensional, no clog, standard Trane catalog RT-PRC010-EN. water spray wets the entire coil surface. What is evaporative-cooled Upward moving air is drawn over the condensing?

4 Wetted surface via a highly efficient large diameter composite propeller fan Unlike air to air condensers, evaporative- powered by a totally enclosed fan- cooled condensing is dependent on the cooled, variable speed drive controlled ambient wet bulb, rather than dry bulb motor. The evaporative effect releases temperature. Wet bulb is generally heat from the condenser coils to the several degrees lower than dry bulb atmosphere and the contained temperature. Utilizing the lower wet bulb refrigerant gas condenses to liquid. temperature to condense the refrigerant vapor can dramatically decrease Self-Cleaning compressor power consumption.

5 The uniqueTrane evaporative condenser Evaporative-cooled condensers, like air- design greatly reduces mineral scale cooled, are designed with heat buildup. Unlike ordinary evaporative- exchangers and also require a cooled condensers, the design allows sump or basin to contain re-circulating the coils to flex during the refrigeration water, a pump and water spray system. cycle; flexing creates a dynamic surface By re-circulating water over the that reduces potential for scale buildup. condenser coils the heat transfer process As the coils flex, mineral deposits that is more efficiently maximized. As fresh may be left behind in the evaporation air is drawn over the wet coils, heat is process are rinsed away by the rejected into the atmosphere and the continuous water spray.

6 Normally, no water used in the heat transfer process chemicals are needed and only minor evaporates. annual maintenance may be required. Because the wet bulb temperature is Any scale present in the re-circulating lower than dry bulb, condensing water passes harmlessly through the temperatures are naturally lowered. sump pump and the unique, non- Lower condensing temperatures clogging cyclone jets. increase the system thermal efficiency Any mineral deposits that may remain in by reducing compressor discharge the sump can be periodically flushed pressure, which in turn reduces away. compressor energy usage. In areas with high mineral Since evaporative-cooled condensers concentrations in supply water, are typically more efficient than air- customers may desire some level of cooled, less coil surface area and airflow chemical treatment to minimize scale are means reduced out buildup.

7 Door sound levels and even further energy savings. Solidly Efficient The IntelliPak evaporative-cooled condenser combines a cooling tower shell with a multiple circuit heat exchanger and a variable speed drive controlled fan motor. Condenser coils are supported by a structural, welded aluminum frame and nested in a low 4 RT-PRC018-EN. Features and Benefits Shielded from UV Rays Condenser fan control Ambient changeover thermostat The evaporative condenser is almost totally shielded from algae-promoting Evaporative-Cooled Condenser UV rays by its high-density shell and Options mist IntelliPak exterior louvered side panels and enclosed top Sump flush water saving control panels provide further protection from Sump heater sunlight.

8 Choose Evaporative-Cooled Unlike heavy zinc coated evaporative- Condensers cooled condensers, Trane 's condenser The IntelliPak Rooftop with coils are designed with continuous evaporatative-cooled condensers is an copper tubing and require no corrosion outstanding choice for: exposed copper acts as a Areas with high energy costs natural agent to inhibit algae growth. Areas with restricted water usage, up For areas with local codes requiring to 40% less water usage with sump treatment, Trane offers optional chemical flush control feeder systems. Hot, dry climates Applications requiring reduced noise The IntelliPak with evaporative-cooled condenser is an engineered product This Rooftop line is a natural and efficient specifically designed to save energy comfort choice for Shopping Malls, dollars, while delivering quiet, cool Office Buildings and other small, comfort.

9 Medium and large commercial /. industrial applications. Trane Evaporative-Cooled Condenser Features Higher energy efficiency Low water usage Low sound levels when compared to air-cooled condensers Fewer internal solder joints Non-clogging water spray nozzles Easy maintenance access Corrosion resistance Copper coils Non-corroding construction Single or dual circuits Scale shedding coils Strong and resilient housing Low ambient control RT-PRC018-EN 5. Application Considerations This catalog contains information Water Discharge and Drain Line Make-up Water Considerations relating to IntelliPak evaporative-cooled Care and judgment should be exercised Traditional bleed method:This method is condensers.

10 For expanded details on in selecting a water discharge site. employed with conventional evaporative IntelliPak rooftops, please see the condensers. Water is continuously standard Trane catalog RT-PRC010-EN. Local Site Discharge: Rooftop or simple storm sewer discharge is generally drained and replaced to help reduce Water Supply acceptable. Do not routinely direct sump mineral concentrations in the condenser Suspended particulate matter, mineral discharge onto areas where the sump. Water level is maintained by concentrations, trash and debris can byproducts of water evaporation or internal float valve. Although not adversely affect performance of any water treatment products are required withTrane's evaporative cooled water-cooled device.


Related search queries