Example: air traffic controller

Packaged Rooftop Unit - Carrier

Rooftop Packaged UnitCOOL ONLY50 TCMA07A950 TCMD08A950 TCMD09A950 TCMD12A950 TCMD14A950 TJM-18A950 TJM-24A950 TJM-28A950 TJM-34A9 Unit Capacity 1 BTU/h66,50086,50094,000113,500135,500169 ,532204,836254,537297,238KW1925283340506 07587 Rated Capacity 2 BTU/h59,50076,50081,000100,700114,500143 ,000182,000225,000246,000KW1722243034425 36672 Power SupplyV-Ph-Hz400-3-50 Total System Power Input 1 CoolingWatts5,9406,9207,8909,87012,31015 ,41019,05021,73028,370 Total System Power Input 2 Watts7,1309,1109,76012,19014,05017,65022 ,47027,66030,940 EER 1 2 1 System Current 1 / / / / / / / / / / AirflowCFM2,4003,0003,4004,0004,8005,300 6,7008,0009,000 CompressorQty / Type1 / Scroll2 / ScrollRefrigerantTypeR410 ARefrigerant Circuit#12 Refrigerant Metering DeviceTypeAcutrolTXV - AdjustableRefrigerant Charge Per / / / / / / / / CoilTypeCu/AlCondenser CoilRows/ FPI2 / 171 / 202 / 203 / 164 / 164 / 17 Evaporator CoilTypeCu/AlEvaporator CoilRows/ FPI4 / 153 / 154 / 153 / 174 / 17 Condenser MotorTypeInduction Motor - Totally EnclosedEvaporator MotorTypeInduction Motor - Totally EnclosedSound Rating (A-Weighted) WeightKg27534538839348

Rooftop Packaged Unit COOL ONLY 50TCMA07A9 50TCMD08A9 50TCMD09A9 50TCMD12A9 50TCMD14A9 50TJM-18A9 50TJM-24A9 50TJM-28A9 50TJM-34A9 Unit Size Cooling TR 6.0 7.5 8.5 10.0 12.5 14.8 18.1 22.5 26.6 Rated Capacity 1 BTU/h 66,500 86,500 94,000 113,500 135,500 169,532 204,836 254,537 297,238 KW 19 25 28 33 40 50 60 75 87 Rated Capacity 2

Tags:

  Carrier, Packaged, Rooftop, Packaged rooftop

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Packaged Rooftop Unit - Carrier

1 Rooftop Packaged UnitCOOL ONLY50 TCMA07A950 TCMD08A950 TCMD09A950 TCMD12A950 TCMD14A950 TJM-18A950 TJM-24A950 TJM-28A950 TJM-34A9 Unit Capacity 1 BTU/h66,50086,50094,000113,500135,500169 ,532204,836254,537297,238KW1925283340506 07587 Rated Capacity 2 BTU/h59,50076,50081,000100,700114,500143 ,000182,000225,000246,000KW1722243034425 36672 Power SupplyV-Ph-Hz400-3-50 Total System Power Input 1 CoolingWatts5,9406,9207,8909,87012,31015 ,41019,05021,73028,370 Total System Power Input 2 Watts7,1309,1109,76012,19014,05017,65022 ,47027,66030,940 EER 1 2 1 System Current 1 / / / / / / / / / / AirflowCFM2,4003,0003,4004,0004,8005,300 6,7008,0009,000 CompressorQty / Type1 / Scroll2 / ScrollRefrigerantTypeR410 ARefrigerant Circuit#12 Refrigerant Metering DeviceTypeAcutrolTXV - AdjustableRefrigerant Charge Per / / / / / / / / CoilTypeCu/AlCondenser CoilRows/ FPI2 / 171 / 202 / 203 / 164 / 164 / 17 Evaporator CoilTypeCu/AlEvaporator CoilRows/ FPI4 / 153 / 154 / 153 / 174 / 17 Condenser MotorTypeInduction Motor - Totally EnclosedEvaporator MotorTypeInduction Motor - Totally EnclosedSound Rating (A-Weighted) WeightKg27534538839348986088011251150 Dimensions (L x D x H)

2 Mm1888 x 1187 x 10512238 x 1510 x 10482238 x 1510 x 12532440 x 2235 x 13753200 x 2485 x 1400 Drain Pipe Connection Sizeinch3/4 Rooftop Packaged UnitCOOL ONLY50 ZPM-36A950 ZPM-48A950 ZPM-60A9 Unit Capacity 1 BTU/h36,00048,00056, Capacity 2 BTU/h30,76641,62948, SupplyV-Ph-Hz400V - 3Ph - 50 HzTotal System Power Input 1 CoolingWatts2,8994,1274,750 Total System Power Input 2 Watts3,2975,0155,810 EER 1 2 1 System Current 1 / / / / AirflowCFM1,2001,6001,650 CompressorQty / Type1 / Recriprocating1 / ScrollRefrigerantTypeR410 ARefrigerant Circuit#SingleRefrigerant Metering DeviceTypePristonTXVR efrigerant Charge Per CoilTypeCu/AlCondenser CoilRows/ FPI2 / 20 Evaporator CoilTypeCu/AlEvaporator CoilRows/ FPI3 / 12 Condenser MotorTypeInduction Motor - Totally EnclosedEvaporator MotorTypeElectronically Commutated (ECM)Sound Rating (A-Weighted) WeightKg127139160 Dimensions (L x D x H)mm1295 x x 8791295 x x 9811295v x x 1184 Drain Pipe Connection Sizeinch3/41 As per AHRI Std 340/360:2007 - Indoor Air Temperatures C (DB) / C (WB) and Outdoor Air Temperatures 35 C (DB) / C (WB) 2 As per ISO 13253.

3 2011 - Indoor Air Temperatures 29 C (DB) / 19 C (WB) and Outdoor Air Temperatures 46 C (DB) / 24 C (WB) Carrier reserves the right to change features and/ or specifications without notice and without incurring any liability Carrier Corporation 2016 Packaged Rooftop Unit50 ZPM-50 TCM-50 TJMP erformance, efficiency, sustainability. We re the complete provides a line of Desert Master Packaged equipment to meet demanding HVAC systems requirements, with Puron (R-410A) refrigerant and environmental efficiency ratings (EER) as high as corrosive sloped condensate pans minimize biological growth in Rooftop units in accordance with ASHRAE (American Society of Heating, Refrigeration and Air Conditioning Engineers) Standard 62-99 (IAQ).Terminal boards, located in the unit control box, facilitate connections to room thermostat, outdoor thermostat(s) and electric heater.

4 Service panels can be quickly removed, permitting easy servicing. Both power and control connections are made on the same side of the unit to simplify installation. In addition, color-cded wires permit easy tracing and diagnostics. Indoor-air qualitySimple, electrical connections Exceptional endurance testsPainted panels tested to ASTM B-117 500 hourssalt spray protection Compressor ProtectionCrankcase heaters are standard for all unitsInternal over temperature protectionFreeze protectionBrazed refrigerant connections for increased leaktightness Low-noise scroll compressorswith low vibration levelsSuperior reliability, efficiency and safetyIt is a compact, fully self- contained, electric cooling unit with horizontal supply and return ducts.

5 The 50ZP units are available in three standard cooling sizes to meet residential and light commercial requirements. Unit installs easily on a ground level package 50 ZPM50 TCM50 TJMAll units feature base rail design with forklift slots and rigging holes for easier maneuvering. Durable packaging protects all units during shipment and storage. Convenient side by side openings permit installation very close to the face of buildings or on roof installationDesigned for durability in any climate, the weather-resistant cabinets are constructed of galvanized steel, bonderized, and all exterior panels are coated with a pre-painted baked enamel - 12 tons3 - 5 tons15 - 27 tonsDesert Master seriesOptimum life-cycle performanceCarrier package units are available in a capacity range from 3 to 27 tons, and offer features such as easy installation, reliability, low operating cost, flexibility of heating option and much important aspect of any HVAC system is the correct supply of treated fresh air to the building occupants, improving indoor air quality (IAQ) levels.

6 Carrier offers a vast range of Packaged units to ensure the best match of the requirements. Performance featuresHFC R-410A non-ozone depleting refrigerant Two independent refrigerant circuits, each with a scrollcompressorLiquid filter drier standard on each circuit Non-corrosive sloped condensate drain pan in accordance withASHRAE 62 standard Angle type return air section with washable type filters(16-27tons)Air treatmentASHRAE Compliant ESMA compliant product EER s up to refrigerant metering deviceFresh air intake capableThermally protected fan motors