Packaged Terminal Air Conditioners & Heat Pumps

Catalog Packaged Terminal Air Conditioners &. heat Pumps Models PTEE and PTHE. PTEE070/PTHE070 (7,000 Btuh). PTEE090/PTHE090 (9,000 Btuh). PTEE120/PTHE120 (12,000 Btuh). PTEE150/PTHE150 (15,000 Btuh). March 2007 PTAC-PRC002-EN. Introduction Packaged Terminal Air Conditioners & heat Pumps Trane Packaged Terminal Air Conditioners (PTACs) and heat Pumps are ideally suited for offices, apartments, hotels, motels, dormitories and nursing homes. Key benefits which make the units a wise choice are: Quieter equipment than ever with Sound Transmission Criteria STC of 27 and NC of 38. Exclusive patent pending De- The Universal Heater as a Humidification Control provides standard option means up to 30% more moisture Everything is stocked and ready removal. to ship.. Flexible digital Interface provides Defrost Control All heat pump wall or unit mounted control models are equipped with heat adjustment.

4 PTAC-PRC002-EN Performance Data Model Number Description Each Packaged Terminal Air Conditioner/Heat Pump is assigned a multiple-character alphanumeric

Tags:

  Performance, Pumps, Heat, Heat pump

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Packaged Terminal Air Conditioners & Heat Pumps

1 Catalog Packaged Terminal Air Conditioners &. heat Pumps Models PTEE and PTHE. PTEE070/PTHE070 (7,000 Btuh). PTEE090/PTHE090 (9,000 Btuh). PTEE120/PTHE120 (12,000 Btuh). PTEE150/PTHE150 (15,000 Btuh). March 2007 PTAC-PRC002-EN. Introduction Packaged Terminal Air Conditioners & heat Pumps Trane Packaged Terminal Air Conditioners (PTACs) and heat Pumps are ideally suited for offices, apartments, hotels, motels, dormitories and nursing homes. Key benefits which make the units a wise choice are: Quieter equipment than ever with Sound Transmission Criteria STC of 27 and NC of 38. Exclusive patent pending De- The Universal Heater as a Humidification Control provides standard option means up to 30% more moisture Everything is stocked and ready removal. to ship.. Flexible digital Interface provides Defrost Control All heat pump wall or unit mounted control models are equipped with heat adjustment.

2 Wall mounted pump control algorithm that Interface uses 2 unpolarized prevents freezing of the wires for connection. condenser, while optimizing comfort. Plug and Play display means on demand commissioning algorithm and automatic start-up delay. 2007 American Standard Inc. All rights reserved PTAC-PRC002-EN. Contents Packaged Terminal Air Conditioners & heat Pumps .. 2. Contents .. 3. Model Number Description .. 4. Application Considerations .. 7. Features and Benefits .. 8. Accessories ..11. performance Data ..13. Electric Power ..19. Dimensions .. 21. Mechanical Specifications .. 24. Warranty .. 26. PTAC-PRC002-EN 3. performance Data Model Number Description Each Packaged Terminal Air The model number helps owner/ Refer to the model number printed Conditioner/ heat Pump is assigned a operator, installing contractors, and on the equipment nameplate when multiple-character alphanumeric service technicians to define the ordering replacement parts or model number that precisely operation, components and options requesting service.

3 Identifies each unit. for a specific unit. An explanation of the identification code that appears on the unit P T E E 0 9 0 1 * A B. nameplate is shown below. 1 2 3 4 5 6 7 8 9 10 11. Digits 1, 2 Packaged Terminal Digit 8 Main Power Supply Digit 10 Miscellaneous Air Conditioner 1 = 230-208V/60Hz/1phase A = Standard Digit 3 Product Type 2 = 265V/60Hz/1phase C = Corrosion Resistant E = Air Conditioner with auxiliary heat 4 = 115V/60Hz/1phase (Hydronic D = Internal Condensate Pump Only). H = heat Pump Digit 9 Electric heat Capacity*. Digit 4 Development Sequence Digit 11 Minor Design U = Universal heater (heater kW Sequence E = Fifth Development series determined by power cord, see Accessories section). Digit 5, 6, 7 Unit Cooling Capacity W = Hydronic (ships with no front cover & no electric heater). 070 = 7,000 Btu 090 = 9,000 Btu 120 = 12,000 Btu 150 = 15,000 Btu The outdoor fan consists of 5 moded plastic Separate Condenser/Evaporator Fan Motors fan blades with slinger ring.

4 The slinger ring Two direct-drive permanent split capacitor two-speed removes condensate by diffusing the water directly motors allow for separate fan operation to onto the outdoor coil for rapid evaporation and increase energy efficiency and reduce noise. increased cooling efficiency The wall sleeve is acoustically and thermally insulated for quietness and increased thermal efficiency. The indoor fan is a cylindrical crossflow Optional power vent blower fan to assure an evenly distributed door accessory. airflow and quiet operation The vent control allows 70 to 80 cfm of fresh air to be drawn into the conditioned area. The rotary compressor is mounted on rubber isolators to ensure minimal vibration and reduced operating noise. Filter - The nylon mesh filters slide directly out of the front panel and The polycarbonate double-sloped drain pan are completely washable for ease allows for better condensate removal and of maintenance.

5 Promotes better indoor air quality. Auto Frost Control removes The digital interface module ice build-up on the outdoor Universal heater kW. has temperature indicators is determined by coil that may occur during versus warmer/cooler settings. the heat pump cycle. the power cord. This diagnostic LCD is capable Room freeze protection prevents of displaying 8 diagnostics : internal room temperatures from Compressor Failure reaching less than 40 degrees by Indoor Temperature No Backup Available energizing the electrical or Indoor Temperature Unit Sensor Failure1. hydronic heat . Indoor Temperature Display Sensor Failure1. Indoor Coil Temperature Failure Outdoor Temperature Failure Outdoor Coil Temperature Failure Configuration Corrupted 4 PTAC-PRC002-EN. Model Number Description Table 1. Hydronic kit options Kit Description H = Hydronic Coil Type W = Water Coil S = Steam Coil Accessory Type K = Kit Power Voltage 01 = 208-230 VAC Figure 1.

6 Hydronic heat option 02 = 265 VAC. 04 = 115 VAC. Coil Positioning L = Left hand hot water coil connection (Standard/. Stocked). R = Right hand hot water coil connection (Not Stocked). Kick Plate S = Standard 2" to 6" adjustable kick plate E = Extended standard base kick plate 7" to 13". M = Upgraded kick plate standard height 2" to 6" (Like the unit ventilator design). U = Upgraded kick plate extended height 7" to 13". (Like the unit ventilator design). Color S = Standard Soft Dove II. C = Special Color PTAC-PRC002-EN 5. Model Number Description Table 2. Accessories Table 2. Accessories Description Part Number Description Part Number Architectural Grilles CONNECTOR FOR HARDWIRE KIT 208/230V - BAYCNHK012. 20 AMP. ARCHITECTURAL ALUMINUM GRILLE BAYAAGL001. CONNECTOR FOR HARDWIRE KIT 208/230V - BAYCNHK013. ARCHITECTURAL ALUMINUM GRILLE -DARK BAYAAGL002.

7 30 AMP. BRONZE. CONNECTOR FOR HARDWIRE KIT 265V - 15 BAYCNHK021. ARCHITECTURAL ALUMINUM GRILLE - SOFT BAYAAGL003. AMP. DOVE. CONNECTOR FOR HARDWIRE KIT 265V - 20 BAYCNHK021. ARCHITECTURAL ALUMINUM GRILLE - SPECIAL BAYAAGL004. AMP. COLOR. CONNECTOR FOR HARDWIRE KIT 265V - 30 BAYCNHK023. Circuit breakers AMP. CIRCUIT BREAKER - 208/230 15 AMP BAYCBKR001. CONNECTOR FOR HARDWIRE KIT 115V - 15 BAYCNHK031. CIRCUIT BREAKER 208/230 20 AMP BAYCBKR002 AMP. CIRCUIT BREAKER - 208/230 30 AMP BAYCBKR003 Subbasev vi Condensate pump UNIVERSAL SUBBASE BAYSUB001. CONDENSATE PUMP 208/230 BAYCPMP001 SOCKET FOR SUBBASE 208/230 20 AMP BAYSCKT001. CONDENSATE PUMP 265 BAYCPMP002 SOCKET FOR SUBBASE 208/230 30 AMP BAYSCKT002. Drain Kit SOCKET FOR SUBBASE 265 20 AMP BAYSCKT003. DRAIN KIT BAYDRAN001 SOCKET FOR SUBBASE 265 30 AMP BAYSCKT004. Filters i) The power switch can be installed on the hard wire junction box and SPARE FILTERS 10 PACK BAYFLTR009 provides a way to shut on and off the PTAC unit.

8 It is an optional ac- Hard Wire Kit cessory when using the power cord to power the PTAC unit. Check local codes for approval HARD WIRE KIT BAYHWRK001 ii) This escutcheon cover should be ordered whenever the display module Leveling Legs is wall mounted or a thermostat or third party provider unit controls are ordered. This escutcheon includes a control cover plate that covers the LEVELING LEG BAYLVLG001 normal unit mounted nomenclature. It comes 5 pieces per pack. iii) All hydronic PTAC chassis come standard without a plastic front cover. Power Switchi If a unit is required to work without heat and without a hydronic kit the POWER SWITCH -115V, 208/230V 265V 30 AMP BAYPSW002 plastic front cover should be ordered. iv) Not required when using a Hard Wire Kit. Stamped grille v) Provides a space to tie into a building's wiring with a receptacle to plug STAMPED ALUMINUM GRILLE - SINGLE PACK BAYSAG001 the unit into.

9 It gives additional leveling and support capabilities and provides a place for fuses, a circuit breaker or a mechanical disconnect STAMPED ALUMINUM GRILLE - TEN PACK BAYSAG002 to be mounted. (30A is for units with 5kW electric heat , 20A for 3kW or Wall Sleeve less electric heat .). vi) All subbases require a socket. For 15 and 20 amp, the 20amp socket 13 INCH WALL SLEEVE BAYWSLV001 can be used on either the 208/230V or the 265V. 18 INCH WALL SLEEVE BAYWSLV002. 24 INCH WALL SLEEVE BAYWSLV003. Power Cord UNIVERSAL POWER CORD 115 VOLT- 15 AMP BAYPCRD007. UNIVERSAL POWER CORD 230 VOLT - 15 AMP BAYPCRD001 or BAYPCRD008. UNIVERSAL POWER CORD 230 VOLT - 20 AMP BAYPCRD002 or BAYPCRD009. UNIVERSAL POWER CORD 230 VOLT - 30 AMP BAYPCRD003. UNIVERSAL POWER CORD 265 VOLT - 15 AMP BAYPCRD004. UNIVERSAL POWER CORD 265 VOLT - 20 AMP BAYPCRD005. UNIVERSAL POWER CORD 265 VOLT - 30 AMP BAYPCRD006.

10 Display Module DISPLAY MODULE (TRANE LOGO STANDARD) BAYTRDM001. DISPLAY MODULE (TRANE LOGO & BAYTRDM002. DEHUMIDIFICATION). Escutcheon Coverii ESCUTCHEON COVER FOR FRONT PANEL BAYTCVR001. (TRANE LOGO). Plastic Front Coveriii PLASTIC FRONT COVER FOR PTAC BAYPCVR001. Connector for Hardwireiv CONNECTOR FOR HARDWIRE KIT 208/230V - BAYCNHK011. 15 AMP. 6 PTAC-PRC002-EN. Application Considerations Curtain wall installation Block and brick veneer installation Frame and brick veneer installation Panel wall installation Panel and block veneer installation Optional leveling leg NOTE: On applications not requiring subbase or leveling legs, unit may be flush mounted to floor. 42 1/2 MIN. 16 1/4 MIN. FINISHED. FLOOR. DIMENSION B. Framing for wall case Framing with lintel Attaching wall sleeve to opening PTAC-PRC002-EN 7. Features and Benefits Quiet Operation Energy Management Default setpoint on first power up: 72 F ( C closest approximation).