Packaged Terminal Air Conditioners & Heat Pumps

CatalogMarch 2007 PTAC-PRC002-ENModels PTEE and PTHEPTEE070/PTHE070 (7,000 Btuh)PTEE090/PTHE090 (9,000 Btuh)PTEE120/PTHE120 (12,000 Btuh)PTEE150/PTHE150 (15,000 Btuh) Packaged Terminal Air Conditioners & Heat PumpsIntroduction 2007 American Standard Inc. All rights reservedPTAC-PRC002-EN Exclusive patent pending De-Humidification Control provides up to 30% more moisture removal. Flexible digital Interface provides wall or unit mounted control adjustment. Wall mounted Interface uses 2 unpolarized wires for connection. Plug and Play display means on demand commissioning algorithm and automatic start-up delay.

Catalog March 2007 PTAC-PRC002-EN Models PTEE and PTHE PTEE070/PTHE070 (7,000 Btuh) PTEE090/PTHE090 (9,000 Btuh) PTEE120/PTHE120 (12,000 Btuh) PTEE150/PTHE150 (15,000 Btuh) Packaged Terminal Air Conditioners & Heat Pumps

Tags:

  Catalog, Pumps

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Packaged Terminal Air Conditioners & Heat Pumps

1 CatalogMarch 2007 PTAC-PRC002-ENModels PTEE and PTHEPTEE070/PTHE070 (7,000 Btuh)PTEE090/PTHE090 (9,000 Btuh)PTEE120/PTHE120 (12,000 Btuh)PTEE150/PTHE150 (15,000 Btuh) Packaged Terminal Air Conditioners & Heat PumpsIntroduction 2007 American Standard Inc. All rights reservedPTAC-PRC002-EN Exclusive patent pending De-Humidification Control provides up to 30% more moisture removal. Flexible digital Interface provides wall or unit mounted control adjustment. Wall mounted Interface uses 2 unpolarized wires for connection. Plug and Play display means on demand commissioning algorithm and automatic start-up delay.

2 The Universal Heater as a standard option means Everything is stocked and ready to ship. Defrost Control All heat pump models are equipped with heat pump control algorithm that prevents freezing of the condenser, while optimizing Terminal Air Conditioners & Heat PumpsTrane Packaged Terminal Air Conditioners (PTACs) and heat Pumps are ideally suited for offices, apartments, hotels, motels, dormitories and nursing homes. Key benefits which make the units a wise choice are: Quieter equipment than ever with Sound Transmission Criteria STC of 27 and NC of Terminal Air Conditioners & Heat Pumps .

3 2 Contents .. 3 Model Number Description .. 4 Application Considerations .. 7 Features and Benefits .. 8 Accessories ..11 Performance Data ..13 Electric Power ..19 Dimensions .. 21 Mechanical Specifications .. 24 Warranty .. 26 Contents4 PTAC-PRC002-ENPerformance DataModel Number DescriptionEach Packaged Terminal Air Conditioner/Heat Pump is assigned a multiple-character alphanumeric model number that precisely identifies each unit. An explanation of the identification code that appears on the unit nameplate is shown model number helps owner/operator, installing contractors, and service technicians to define the operation, components and options for a specific unit.

4 Refer to the model number printed on the equipment nameplate when ordering replacement parts or requesting E E 0 9 0 1 * A B 12 3 4 5 6 7 8 91011 Digits 1, 2 Packaged Terminal Air ConditionerDigit 3 Product TypeE = Air Conditioner with auxiliaryheatH= Heat PumpDigit 4 Development SequenceE = Fifth Development seriesDigit 5, 6, 7 Unit Cooling Capacity070 = 7,000 Btu090 = 9,000 Btu120 = 12,000 Btu150 = 15,000 BtuDigit 8 Main Power Supply1 = 230-208V/60Hz/1phase2 = 265V/60Hz/1phase4 = 115V/60Hz/1phase (Hydronic Only)Digit 9 Electric Heat Capacity*U = Universal heater (heater kW determined by power cord,see Accessories section)W = Hydronic (ships with no front cover & no electric heater)

5 Digit 10 MiscellaneousA = StandardC = Corrosion ResistantD = Internal Condensate PumpDigit 11 Minor Design SequenceThe indoor fan is a cylindrical crossflowblower fan to assure an evenly distributed airflow and quiet operationThe outdoor fan consists of 5 moded plastic fan blades with slinger ring. The slinger ringremoves condensate by diffusing the water directlyonto the outdoor coil for rapid evaporation and increased cooling efficiencySeparate Condenser/Evaporator Fan MotorsTwo direct-drive permanent split capacitor two-speed motors allow for separate fan operation to increase energy efficiency and reduce wall sleeve is acoustically and thermally insulated for quietness and increased thermal efficiency.

6 Filter - The nylon mesh filters slide directly out of the front panel and are completely washable for ease of Frost Control removes ice build-up on the outdoor coil that may occur during the heat pump freeze protection prevents internal room temperatures from reaching less than 40 degrees by energizing the electrical or hydronic polycarbonate double-sloped drain pan allows for better condensate removal and promotes better indoor air rotary compressor is mounted on rubber isolators to ensure minimal vibration and reduced operating digital interface module has temperature indicators versus warmer/cooler diagnostic LCD is capable of displaying 8 diagnostics :Compressor FailureIndoor Temperature No Backup AvailableIndoor Temperature Unit Sensor Failure1 Indoor Temperature Display Sensor Failure1 Indoor Coil Temperature FailureOutdoor Temperature FailureOutdoor Coil Temperature FailureConfiguration CorruptedThe vent control allows 70 to 80 cfm of fresh air to be drawn into the conditioned power ventdoor heater kWis determined by the power Number DescriptionTable 1.

7 Hydronic kit optionsKit DescriptionH = HydronicCoil TypeW= Water CoilS = Steam CoilAccessory TypeK=KitPower Voltage01 = 208-230 VAC02 = 265 VAC04 = 115 VACCoil PositioningL= Left hand hot water coil connection (Standard/Stocked)R = Right hand hot water coil connection (Not Stocked)Kick PlateS = Standard 2" to 6" adjustable kick plateE = Extended standard base kick plate 7" to 13"M = Upgraded kick plate standard height 2" to 6" (Like the unit ventilator design)U = Upgraded kick plate extended height 7" to 13" (Like the unit ventilator design)ColorS = Standard Soft Dove IIC = Special ColorFigure heat option6 PTAC-PRC002-ENModel Number DescriptionTable 2.

8 AccessoriesDescriptionPart NumberArchitectural GrillesARCHITECTURAL ALUMINUM GRILLEBAYAAGL001 ARCHITECTURAL ALUMINUM GRILLE -DARK BRONZEBAYAAGL002 ARCHITECTURAL ALUMINUM GRILLE - SOFT DOVEBAYAAGL003 ARCHITECTURAL ALUMINUM GRILLE - SPECIAL COLORBAYAAGL004 Circuit breakersCIRCUIT BREAKER - 208/230 15 AMPBAYCBKR001 CIRCUIT BREAKER 208/230 20 AMPBAYCBKR002 CIRCUIT BREAKER - 208/230 30 AMPBAYCBKR003 Condensate pumpCONDENSATE PUMP 208/230 BAYCPMP001 CONDENSATE PUMP 265 BAYCPMP002 Drain KitDRAIN KITBAYDRAN001 FiltersSPARE FILTERS 10 PACKBAYFLTR009 Hard Wire KitHARD WIRE KITBAYHWRK001 Leveling LegsLEVELING LEGBAYLVLG001 Power SwitchiPOWER SWITCH -115V.

9 208/230V 265V 30 AMP BAYPSW002 Stamped grilleSTAMPED ALUMINUM GRILLE - SINGLE PACKBAYSAG001 STAMPED ALUMINUM GRILLE - TEN PACKBAYSAG002 Wall Sleeve13 INCH WALL SLEEVEBAYWSLV00118 INCH WALL SLEEVEBAYWSLV00224 INCH WALL SLEEVEBAYWSLV003 Power CordUNIVERSAL POWER CORD 115 VOLT- 15 AMPBAYPCRD007 UNIVERSAL POWER CORD 230 VOLT - 15 AMP BAYPCRD001 or BAYPCRD008 UNIVERSAL POWER CORD 230 VOLT - 20 AMP BAYPCRD002 or BAYPCRD009 UNIVERSAL POWER CORD 230 VOLT - 30 AMP BAYPCRD003 UNIVERSAL POWER CORD 265 VOLT - 15 AMP BAYPCRD004 UNIVERSAL POWER CORD 265 VOLT - 20 AMP BAYPCRD005 UNIVERSAL POWER CORD 265 VOLT - 30 AMP BAYPCRD006 Display ModuleDISPLAY MODULE (TRANE LOGO STANDARD)BAYTRDM001 DISPLAY MODULE (TRANE LOGO & DEHUMIDIFICATION)BAYTRDM002 Escutcheon CoveriiESCUTCHEON COVER FOR FRONT PANEL (TRANE LOGO)

10 BAYTCVR001 Plastic Front CoveriiiPLASTIC FRONT COVER FOR PTACBAYPCVR001 Connector for HardwireivCONNECTOR FOR HARDWIRE KIT 208/230V - 15 AMPBAYCNHK011 CONNECTOR FOR HARDWIRE KIT 208/230V - 20 AMPBAYCNHK012 CONNECTOR FOR HARDWIRE KIT 208/230V - 30 AMPBAYCNHK013 CONNECTOR FOR HARDWIRE KIT 265V - 15 AMPBAYCNHK021 CONNECTOR FOR HARDWIRE KIT 265V - 20 AMPBAYCNHK021 CONNECTOR FOR HARDWIRE KIT 265V - 30 AMPBAYCNHK023 CONNECTOR FOR HARDWIRE KIT 115V - 15 AMPBAYCNHK031 Subbasev viUNIVERSAL SUBBASEBAYSUB001 SOCKET FOR SUBBASE 208/230 20 AMPBAYSCKT001 SOCKET FOR SUBBASE 208/230 30 AMPBAYSCKT002 SOCKET FOR SUBBASE 265 20 AMPBAYSCKT003 SOCKET FOR SUBBASE 265 30 AMPBAYSCKT004i)The power switch can be installed on the hard wire junction box and provides a way to shut on and off the PTAC unit.