Packaged Unit Cross-Reference Guide

Whenever you are asked to cross reference a brand of HVAC Packaged equipment, special care must betaken to address all of the potential get the voltage, fuel type, and unit configuration! Never rely solely on the model addition, sometimes the model number does not reflect field or factory installed features & accessories. To that end, its always important to "exclude" any items which are not specifically listed on your attached cross reference charts are NOT intended to be a complete and total list of all models in the , the goal of building this reference Guide is to simplify cross referencing roughly 60-70% of the modelsencountered on a daily note: It is the contractor's responsibility to confirm the correctness of the project tonnagerequirements, voltage, & any required unit Cross-Reference GuideCARRIER12345678 VSample Model #:4 8 D J Q 0 0 8 - 5 Digits 1,2:Voltage Indicato

Whenever you are asked to cross reference a brand of HVAC packaged equipment, special care must be taken to address all of the potential variables.

Tags:

  Guide, Cross, Reference, Unit, Packaged, Cross reference, Packaged unit cross reference guide

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Packaged Unit Cross-Reference Guide

1 Whenever you are asked to cross reference a brand of HVAC Packaged equipment, special care must betaken to address all of the potential get the voltage, fuel type, and unit configuration! Never rely solely on the model addition, sometimes the model number does not reflect field or factory installed features & accessories. To that end, its always important to "exclude" any items which are not specifically listed on your attached cross reference charts are NOT intended to be a complete and total list of all models in the , the goal of building this reference Guide is to simplify cross referencing roughly 60-70% of the modelsencountered on a daily note: It is the contractor's responsibility to confirm the correctness of the project tonnagerequirements, voltage, & any required unit Cross-Reference GuideCARRIER12345678 VSample Model #:4 8 D J Q 0 0 8 - 5 Digits 1,2:Voltage Indicator.

2 48 = Gas/Elect Pkg unit -1575/3/6050 = Electric Pkg unit -3208/240-1-60-5208/240-3-60 Digits 3,4:-6460-3-60 Product Series, for example:DJ, LJ, TJ, HJ, HEDigits 6,7,8: Tonnage:0043-tonsDigit 5: Heat Type:0054-tonsDLow Heat0065-tonsEMed Heat0076-tonsFHigh Heat, Low Heat, Low NOX01210-tonsNHigh Heat, Low Pump01615-tons02018-tons02520-tons02825- tonsBRYANT12345678910 1112 Sample Model #:5 8 1 B E V 0 9 0 1 8 0 Digits 1,2,3,4:Digits 10, 11, 12: BTUH InputProduct Series, for example:115115,000 Input581B = 3 to ton Gas/Elec180180,000 InputDigits 5:Voltage Indicator:Digits 7,8,9: Tonnage:E460-3-600363-tonsJ208/240-1-600 484-tonsP208/240-3-600605-tonsT575/3 6 Gas/ Spark NumberDigit NumberOLD LENNOX12345678910 11 VSample Model #:G C S 1 6 9 5 3 2 0 0 -YDigits 1,2,3:Digits 10, 11, 12: BTUH InputGCS = Gas/Electric Pkg125125,000 InputCHA = Electric / Electric Pkg200200,000 InputCHP = Heat Pump Pkg270270,000 InputDigits 4,5:Digits 6,7,8: Tonnage:Product Series, for example:4133-tons, 3-phase9,11,16,20,24 series5134-tons, 3-phase6535-tons, 3-phaseVoltage Indicator.

3 8136-tons, 3-phaseP208 , 3-phaseY208/240-3-60135310-tons, , 3-phaseJ575/3/60185315-tons, 3-phase255320-tons, 3-phase300325-tons, 3-phaseTRANE12345678910 Sample Model #:Y S C 0 9 0 E 3 E LDigits 1:Digit 10: Heating CapacityY = Gas/Electric Pkg UnitB6kw - 3phT = Elect / Elect Pkg UnitE8kw - 3phW = Heat Pump Pkg UnitG12kw - 3phDigit 2: EfficiencyJ23kw - 3phS = Std Eff / H = High EffLLow Ht, GasDigit 3: C = ConvertibleMMed Ht, GasHHigh Ht, GasDigits 3,4,5: Tonnage:0363-tonsDigit 9: unit Controls0484-tonsEElectro-Mech0605-tonsR ReliaTel 8: Voltage 7: Major Design = R410 ADigit NumberDigit NumberYORK12345678910 Sample Model #:Z H 0 9 0 N 1 0 A 2 Digits 1:Digit 10: Voltage IndicatorZ = Cooling Pkg Unit2 208/240-3-60X = Heat Pump Pkg Unit4 460-3-605 575/3/60 Digit 2: EfficiencyH = 11+ EER, A/CDigits 9: AirflowP = 11+ EER, HPAStd MotorJ = 11+ EER A/CNHi Static MotorF = 10 to 11 EERO thersFact Ins O/A AccessR = ReHeatDigits 6,7,8: HeatingDigits 3,4,5: Tonnage:N10105,000 Input0363-tonsN15150,000 Input0484-tonsN20200,000 Number