Example: stock market

Page 1/8 Safety Data Sheet acc. to OSHA HCS 1 …

Page 1/8 Safety data Sheetacc. to osha HCSP rinting date 04/28/2016 Reviewed on 04/28 Identification Product identifier Product Name: Tuning Solution for ICP-MS, Part Number 5185-5959 Part Number:5185-5959 Application of the substance / the mixtureAnalytical Chemistry2 x 500 mL Solution Details of the supplier of the Safety data Sheet Manufacturer/Supplier:Agilent Technologies, Inc5301 Stevens Creek Clara, CA 95051 USA Information department:product Safety department Emergency telephone number:Emergency Phone Number (24 hours)CHEMTREC (800-424-9300)Outside US: 703-527-38872 Hazard(s) identification Classification of the substance or mixtureGHS07 Skin Irrit.

Page 2/8 Safety Data Sheet acc. to OSHA HCS Printing date 04/28/2016 Reviewed on 04/28/2016 Product Name: Tuning Solution for ICP-MS, Part Number 5185-5959

Tags:

  Sheet, Data, Safety, Pages, Osha, 8 safety data sheet acc, To osha hcs, Page 1 8 safety data sheet acc, To osha hcs 1

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Page 1/8 Safety Data Sheet acc. to OSHA HCS 1 …

1 Page 1/8 Safety data Sheetacc. to osha HCSP rinting date 04/28/2016 Reviewed on 04/28 Identification Product identifier Product Name: Tuning Solution for ICP-MS, Part Number 5185-5959 Part Number:5185-5959 Application of the substance / the mixtureAnalytical Chemistry2 x 500 mL Solution Details of the supplier of the Safety data Sheet Manufacturer/Supplier:Agilent Technologies, Inc5301 Stevens Creek Clara, CA 95051 USA Information department:product Safety department Emergency telephone number:Emergency Phone Number (24 hours)CHEMTREC (800-424-9300)Outside US: 703-527-38872 Hazard(s) identification Classification of the substance or mixtureGHS07 Skin Irrit.

2 2 H315 Causes skin Irrit. 2A H319 Causes serious eye irritation. Label elements GHS label elementsThe product is classified and labeled according to the Globally Harmonized System (GHS). Hazard pictogramsGHS07 Signal wordWarning Hazard statementsCauses skin serious eye irritation. Precautionary statementsWear protective eye protection / face in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue treatment (see on this label).If skin irritation occurs: Get medical eye irritation persists: Get medical advice/attention. Classification system: NFPA ratings (scale 0 - 4)100 Health = 1 Fire = 0 Reactivity = 0 HMIS-ratings (scale 0 - 4) HEALTH FIRE REACTIVITY100 Health = 1 Fire = 0 Reactivity = 0(Contd.)

3 On page 2) US Page 2/8 Safety data Sheetacc. to osha HCSP rinting date 04/28/2016 Reviewed on 04/28/2016 Product Name: Tuning Solution for ICP-MS, Part Number 5185-5959(Contd. of page 1) Other hazards Results of PBT and vPvB assessment PBT:Not applicable. vPvB:Not Composition/information on ingredients Chemical characterization: Mixtures Description:Mixture of the substances listed below with nonhazardous additions. Dangerous components:7697-37-2 nitric Chemical identification of the substance/preparation7439-93-2 Lithium from Lithium carbonate< magnesium< Thallium from Thallium nitrate< Cerium from Cerium(III) nitrate hexahydrate< cobalt< Yttrium from Yttrium oxide< water, distilled, conductivity or of similar First-aid measures Description of first aid measures After inhalation:In case of unconsciousness place patient stably in side position for transportation.

4 After skin contact:Immediately wash with water and soap and rinse thoroughly. After eye contact:Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor. After swallowing:If symptoms persist consult doctor. Information for Doctor: Most important symptoms and effects, both acute and delayedNo further relevant information available. Indication of any immediate medical attention and special treatment neededNo further relevant information Fire-fighting measures Extinguishing media Suitable extinguishing agents:CO2, extinguishing powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

5 Special hazards arising from the substance or mixtureNo further relevant information available. Advice for firefighters Protective equipment:No special measures Accidental release measures Personal precautions, protective equipment and emergency proceduresNot required. Environmental precautions:No special measures required. Methods and material for containment and cleaning up:Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).Ensure adequate ventilation. Reference to other sectionsSee Section 7 for information on safe Section 8 for information on personal protection Section 13 for disposal information.

6 US (Contd. on page 3)Page 3/8 Safety data Sheetacc. to osha HCSP rinting date 04/28/2016 Reviewed on 04/28/2016 Product Name: Tuning Solution for ICP-MS, Part Number 5185-5959(Contd. of page 2) Handling and storage Handling: Precautions for safe handlingEnsure good ventilation/exhaustion at the formation of aerosols. Information about protection against explosions and fires:No special measures required. Conditions for safe storage, including any incompatibilities Storage: Requirements to be met by storerooms and receptacles:No special requirements. Information about storage in one common storage facility:Not required.

7 Further information about storage conditions:Keep receptacle tightly sealed. Specific end use(s)No further relevant information Exposure controls/personal protection Additional information about design of technical systems:No further data ; see item 7. Control parameters Components with limit values that require monitoring at the workplace:7697-37-2 nitric acidPEL Long-term value: 5 mg/m , 2 ppmREL Short-term value: 10 mg/m , 4 ppmLong-term value: 5 mg/m , 2 ppmTLV Short-term value: 10 mg/m , 4 ppmLong-term value: mg/m , 2 ppm Additional information:The lists that were valid during the creation were used as basis. Exposure controls Personal protective equipment: General protective and hygienic measures:Keep away from foodstuffs, beverages and remove all soiled and contaminated hands before breaks and at the end of contact with the eyes and skin.

8 Breathing equipment:In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use respiratory protective device that isindependent of circulating air. Protection of hands:Protective glovesThe glove material has to be impermeable and resistant to the product/ the substance/ the to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical of the glove material on consideration of the penetration times, rates of diffusion and the degradation Material of glovesThe selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer tomanufacturer.

9 As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and hastherefore to be checked prior to the application. Penetration time of glove materialThe exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.(Contd. on page 4) US Page 4/8 Safety data Sheetacc. to osha HCSP rinting date 04/28/2016 Reviewed on 04/28/2016 Product Name: Tuning Solution for ICP-MS, Part Number 5185-5959(Contd. of page 3) Eye protection:Tightly sealed goggles9 Physical and chemical properties Information on basic physical and chemical properties General Information Appearance:Form:LiquidColor:Colorless Odor:Odorless Odour Threshold:Not applicable.

10 PH-value:<1 Change in conditionMelting point/Melting range:0 C (32 F)Boiling point/Boiling range:100 C (212 F) Flash point:Not applicable. Flammability (solid, gaseous):Not applicable. Ignition temperature:Decomposition temperature:Not applicable. Auto igniting:Product is not selfigniting. Danger of explosion:Product does not present an explosion hazard. Explosion limits:Lower:Not :Not applicable. Vapor pressure at 20 C (68 F):23 hPa (17 mm Hg) g/mL @ 20 C Relative densityNot applicable. Vapor densityNot applicable. Evaporation rateNot applicable. Solubility in / Miscibility withWater:Miscible Partition coefficient (n-octanol/water):Not applicable.


Related search queries