Example: barber

Page 863 - HENRY - LIQUID REFRIGERANT …

REFRIGERATION. HENRY TECHNOLOGIES - LIQUID REFRIGERANT RECEIVERS. S-8060 SERIES VERTICAL RECEIVERS. Receivers should be selected based on the operating charge for all system components, including the LIQUID lines. It is usual to add a small percentage to cover the REFRIGERANT in long runs of suction and discharge lines, etc. It is essential that the maximum operating charge be determined, , winter charge in air cooled condenser having flooded head pressure control, this being much greater than the normal summer charge. S-8060 SERIES VERTICAL RECEIVERS. *PUMP DOWN CAPACITY (lbs) DIMENSIONS (in) CONNECTIONS. PART NO R-134a R-22 R404A/R-507 A B C D Inlet Outlet WT(lb). S-8060 10 7 7 1/4 FLARE 1/4 FLARE 2. REFRIGERATION. S-8061 5 5 1/4 FLARE 1/4 FLARE 2. S-8062 10 1/4 FLARE 1/4 FLARE 3.

REFRIGERATION HENRY TECHNOLOGIES - LIQUID REFRIGERANT RECEIVERS S-8060 SERIES VERTICAL RECEIVERS Receivers should be selected based on the operating charge for all

Tags:

  Liquid, Refrigerant, Receiver, Liquid refrigerant, Liquid refrigerant receivers, Receivers receivers

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Page 863 - HENRY - LIQUID REFRIGERANT …

1 REFRIGERATION. HENRY TECHNOLOGIES - LIQUID REFRIGERANT RECEIVERS. S-8060 SERIES VERTICAL RECEIVERS. Receivers should be selected based on the operating charge for all system components, including the LIQUID lines. It is usual to add a small percentage to cover the REFRIGERANT in long runs of suction and discharge lines, etc. It is essential that the maximum operating charge be determined, , winter charge in air cooled condenser having flooded head pressure control, this being much greater than the normal summer charge. S-8060 SERIES VERTICAL RECEIVERS. *PUMP DOWN CAPACITY (lbs) DIMENSIONS (in) CONNECTIONS. PART NO R-134a R-22 R404A/R-507 A B C D Inlet Outlet WT(lb). S-8060 10 7 7 1/4 FLARE 1/4 FLARE 2. REFRIGERATION. S-8061 5 5 1/4 FLARE 1/4 FLARE 2. S-8062 10 1/4 FLARE 1/4 FLARE 3.

2 S-8063 10 1/4 FLARE 1/4 FLARE 4. S-8064 10 1/4 FLARE 1/4 FLARE 6. S-8065 12 8 8 3/8 FLARE 3/8 FLARE 10. S-8066 18 15 15 3/8 FLARE 1/2 FLARE 16. S-8067 24 1/2 FLARE 1/2 FLARE 21. S-8068 30 5/8 FLARE 5/8 FLARE 26. Maximum WP 450 PS. *All Pump Down Capacities are calculated @ 90% of receiver volume @ 90 F. S-8600 SERIES HORIZONTAL RECEIVERS. S-8600 SERIES HORIZONTAL RECEIVERS. *PUMP DOWN CAPACITY (lbs) DIMENSIONS (in) CONNECTIONS. PART NO R-134a R-22 R404A/R-507 A B C Inlet Outlet FPT SHIP WEIGHT. (lb). S-8600 28 5/8 ODS 5/8 ODS 3/8 19. S-8610 36 5/8 ODS 5/8 ODS 3/8 25. S-8620 30 5/8 ODS 5/8 ODS 3/8 24. S-8630 36 5/8 ODS 5/8 ODS 3/8 28. S-8600V SERIES HORIZONTAL RECEIVERS WITH BRACKETS & VALVES. *PUMP DOWN CAPACITY (lbs) DIMENSIONS (in) CONNECTIONS. PART NO R-134a R-22 R404A/R-507 A B C D E F G Inlet Outlet FPT SHIP.

3 WEIGHT. (lb). S-8600V 28 14 .44 1/2 ODS 1/2 ODS 3/8 19. S-8630V 36 18 .44 1/2 ODS 1/2 ODS 3/8 28. *Pump Down Capacities are calculated @ 90% of receiver volume @ 90 F. 863.