Example: stock market

PanelView Plus to PanelView Plus 6 Catalog Number ...

Migration GuidePanelView plus to PanelView plus 6 Catalog Number ConversionsAbout This PublicationThis publication provides information about how to convert the following terminals to the new generation PanelView plus 6 terminals: PanelView plus and PanelView plus CE terminals PanelView plus 400 and 600 terminals PanelView plus compact terminalsThe new PanelView plus 6 platform is available with or without extended features and file viewers. There is no longer a distinction between PanelView plus and PanelView plus CE picPageAbout This Publication1 Platform Comparisons3 Windows CE Operating System4 PanelView plus 6 - 400 and 600 Terminal Selections5 Catalog Number Conversion Tables - 400 and 600 Terminals6 Legacy PanelView plus 400 and 600 Terminal Support8 PanelView plus 6 - Product Selections9 PanelView plus 6 - Accessories11 Catalog Number Conversion Tables - Terminals13 Logic Module Conversions - Terminals25 Legacy Panel

PanelView Plus Compact terminals The new PanelView Plus 6 platform is available with or without extended features and file viewers. There is no longer a distinction between PanelView Plus and PanelView Plus CE terminals. Topic Page About This Publication 1 Platform Comparisons 3 Windows CE 6.0 Operating System 4 PanelView Plus 6 - 400 and ...

Tags:

  Plus, Compact, Panelview, Panelview plus, Panelview plus compact

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of PanelView Plus to PanelView Plus 6 Catalog Number ...

1 Migration GuidePanelView plus to PanelView plus 6 Catalog Number ConversionsAbout This PublicationThis publication provides information about how to convert the following terminals to the new generation PanelView plus 6 terminals: PanelView plus and PanelView plus CE terminals PanelView plus 400 and 600 terminals PanelView plus compact terminalsThe new PanelView plus 6 platform is available with or without extended features and file viewers. There is no longer a distinction between PanelView plus and PanelView plus CE picPageAbout This Publication1 Platform Comparisons3 Windows CE Operating System4 PanelView plus 6 - 400 and 600 Terminal Selections5 Catalog Number Conversion Tables - 400 and 600 Terminals6 Legacy PanelView plus 400 and 600 Terminal Support8 PanelView plus 6 - Product Selections9 PanelView plus 6 - Accessories11 Catalog Number Conversion Tables - Terminals13 Logic Module Conversions - Terminals25 Legacy PanelView plus Terminal Support26 Additional Resources272 Rockwell Automation Publication 2711P-AP003F-EN-P - January 2017 PanelView

2 plus to PanelView plus 6 Catalog Number ConversionsSummary of ChangesThis migration guide contains new and updated information. Changes throughout this revision are marked by change bars as shown to the left of this picPa gesAdded information about free user memory available for PanelView plus 6 , 5, and Automation Publication 2711P-AP003F-EN-P - January 20173 PanelView plus to PanelView plus 6 Catalog Number ConversionsPlatform ComparisonsThis table compares the differences between the new generation PanelView plus 6 and the legacy PanelView plus 1 - PanelView plus 6 and PanelView plus Platform ComparisonFeaturePlatformPlatformPanelVi ew plus 6 Terminals400 and 600 PanelView plus Terminals400 and 600 PanelView plus 6 Terminals700, 1000, 1250, 1500 PanelView plus and PanelView plus CE terminals700, 1000, 1250.

3 1500 Operating systemWindows CE Windows CE Windows CE tor yTalk View ME Station (runtime) softwareVersion or laterVersion or laterVersion ViewPoint softwareNoNoVersion or laterVersion on series E or later terminals, requires 128 MB RAMA pplication compatibilitySupports FactoryTalk View ME applications, version or laterSupports FactoryTalk View ME applications, version FactoryTalk View ME applications, version or laterSupports FactoryTalk View ME applications, version p e n a rc h i t e c t u reYe s Ye s Ye compact frameworkVersion Version , not installedVersion Version , not installedFile systemDatalight Reliance with FAT support Datalight Reliance with FAT supportFAT16, FAT32.

4 On 512 MB versionCPUARM, GHzNEC VR5532A MIPS, 350 MHzx86, GHzx86, Intel Celeron, 650 MHzRAM256 MB DDR2 (chip onboard)4264 MiB/s peak64 MB PC100 SDRAM SODIMM800 MiB/s peak512 MB DDR2 (chip onboard)4264 MiB/s peak64, 128, 256, or 512 MB,PC100 SDRAM SODIMM800 MiB/s peakInternal storage512 MB nonvolatile memory(approx. 73 MB free user memory)64 MB 512 MB nonvolatile memory(approx. 79 MB free user memory)64 MB, 128 MB, or 256 MBReal-time clockYesYesYesYesInterfacesSecure Digital (SD) slot1 Secure Digital high-capacity (SDHC) slot supports 1784-SDx cards 1 Secure Digital high-capacity (SDHC) slot supports 1784-SDx cards CompactFlash (CF) slot 1 CF Type I 1 CF Type I USB ports1 USB-A, high speed1 USB-B, high-speed, 4-pin1 USB-A, USB-A, high speed2 USB-A, 1 PCI, 32-bit1 PCI, 32-bitCommunication InterfacesEthernet(1) 10/100 Mbps, Auto-MDI/MDI-X(1) 10/100 Mbps(1) 10/100 Mbps, Auto-MDI/MDI-X(1) 10/100 MbpsRS-232(1) DB9(1) DB9(1) DB9(1)

5 DB9 ControlNet Add-on communication moduleAdd-on communication moduleAdd-on communication moduleDH+ Add-on communication moduleAdd-on communication moduleAdd-on communication moduleDH-485 Add-on communication moduleAdd-on communication moduleAdd-on communication moduleRemote I/O Add-on communication module Add-on communication moduleDeviceNet Add-on communication module Add-on communication moduleInput powerNoninsolated DC voltage or AC voltageNonisolated DC voltage or AC voltageIsolated DC voltage or AC voltageIsolated DC voltage, nonisolated DC voltage, or AC voltage4 Rockwell Automation Publication 2711P-AP003F-EN-P - January 2017 PanelView plus to PanelView plus 6 Catalog Number ConversionsWindows CE Operating SystemAll PanelView plus 6 terminals run the Windows CE operating system (OS), providing OS elements that meet most user needs.

6 Additional functionality is available by ordering terminals with optional, extended Features400 Terminals600 TerminalsCat. FeaturesFTP server VNC Client/server ActiveX controls Third-party device support PDF reader Optional Extended FeaturesWeb browser - Internet Explorer Remote desktop connection (1)(1) The remote desktop connection is not currently supported on PanelView plus 6 - 600 terminals with extended features. Media player Microsoft Office file viewers PowerPoint Excel Word WordPad tex t editor OptionalExtended FeaturesRockwell Automation Publication 2711P-AP003F-EN-P - January 20175 PanelView plus to PanelView plus 6 Catalog Number ConversionsPanelView plus 6 - 400 and 600 Terminal SelectionsThe table shows the Catalog Number breakdown for the new PanelView plus 6 - 400 and 600 b l e 2 and Ta b l e 3 list the new Catalog numbers available for the PanelView plus 6 - 400 and 600 terminals without extended features and file viewers.

7 These Catalog numbers are referenced in Catalog Number Conversion Tables - 400 and 600 Terminals on page TypeDisplay SizeDisplay TypeCommunicationPowerOperating System|||||||2711P-K = Keypad4= = Color 5 = RS-232, USBA = AC 8 = Windows CE B = Keypad and Touch6 = = Grayscale20 = Ethernet, RS-232, USB D = DC 9 = Windows CE with extended featuresT = TouchTable 2 - PanelView plus 6 - 400 Terminals without Extended FeaturesCat. PortsUSB PortsInputPowerMemory (MB) (1)(1)The terminals support FactoryTalk View Machine Edition software, version or later, and the Windows CE operating and TouchSizeTypeRS-232 EthernetHostDeviceRAMN onvolatile 2711P-K4M5A8 AC256512 MB nonvolatile memory(approx.)

8 73 MB free user memory)2711P-K4M5D8 DC2711P-K4M20A8 AC2711P-K4M20D8 AC2711P-K4C5D82711P-B4C5D8 DC2711P-K4C20A82711P-B4C20A8 AC2711P-K4C20D82711P-B4C20D8 DCTable 3 - PanelView plus 6 - 600 Terminals without Extended FeaturesCat. PortsUSB PortsInputPowerMemory (MB) (2)(2)The terminals support FactoryTalk View Machine Edition software, version or later, and the Windows CE operating and TouchSizeTypeRS-232 EthernetHostDeviceRAMN onvolatile AC256 512 MB nonvolatile memory(approx. 73 MB free user memory)2711P-K6M5D82711P-T6M5D82711P-B6M 5D8 DC2711P-K6M20A82711P-T6M20A82711P-B6M20A 8 AC2711P-K6M20D82711P-T6M20D82711P-B6M20D 8 DC2711P-K6C5A8 (1)(1)These terminals are available with extended features and file viewers by changing the 8 at the end of the Catalog Number to a 9.

9 For example, (1)2711P-B6C5A8(1) AC2711P-K6C5D8(1)2711P-T6C5D8(1)2711P-B6 C5D8(1) DC2711P-K6C20A8(1)2711P-T6C20A8(1)2711P- B6C20A8(1) AC2711P-K6C20D8(1)2711P-T6C20D8(1)2711P- B6C20D8(1) DC6 Rockwell Automation Publication 2711P-AP003F-EN-P - January 2017 PanelView plus to PanelView plus 6 Catalog Number ConversionsCatalog Number Conversion Tables - 400 and 600 TerminalsTa b l e b l e 6 assist you in how to select a new generation PanelView plus 6 terminal replacement for the following : PanelView plus 6 - 400 or 600 terminal that is equivalent to a PanelView plus 400 or 600 terminal PanelView plus 6 compact terminal that is equivalent to a PanelView plus compact terminalTable 4 - Catalog Number Conversions for 400 TerminalsFrom Existing PanelView plus 400 To New PanelView plus 6 - 400 Keypad and Touch Screen TerminalsTerminal with Ethernet and RS-232 communication ports2711P-B4C20A2711P-B4C20A82711P-B4C2 0D2711P-B4205D8Te r m i n a lRS-232 communication port2711P-B4C5A2711P-B4C5A82711P-B4C5D27 11P-B4C5D8Te r m i n a lDH-485 communication port2711P-B4C3A2711P-B4C20A8(1)(1)

10 This terminal supports DH-485 communication through the RS-232 communication (1)Keypad TerminalsTerminal with Ethernet and RS-232 communication ports2711P-K4C20A2711P-K4C20A82711P-K4C2 0D2711P-K4C20D82711P-K4M20A2711P-K4M20A8 2711P-K4M20D2711P-K4M20D8Te r m i n a l w i t hRS-232 communication port2711P-K4C5A2711P-K4C5A82711P-K4C5D27 11P-K4C5D82711P-K4M5A2711P-K4M5A82711P-K 4M5D2711P-K4M5D8Te r m i n a lDH-485 communication port2711P-K4C3A2711P-K4C20A8(1)2711P-K4C 3D2711P-K4C20D8(1)2711P-K4M3A2711P-K4M20 A8(1)2711P-K4M3D2711P-K4M20D8(1)Table 5 - Catalog Number Conversions for PanelView plus compact TerminalsFrom Existing PanelView plus CompactTo New PanelView plus 6 CompactTerminal with Ethernet and RS-232 communication ports2711PC-B4C20D2711PC-B4C20A82711PC-K 4M20D2711PC-K4M20D82711PC-T6C20D2711PC-T 6C20D82711PC-T6M20D2711PC-T6M20D82711PC- T10C4D12711PC-T10C4D8 Rockwell Automation Publication 2711P-AP003F-EN-P - January 20177 PanelView plus to PanelView plus 6 Catalog Number ConversionsTable 6 - Catalog Number Conversions for 600 TerminalsFrom Existing PanelView plus 600 To New Pa