Par t C Fire Resisting Construction - Buildings Department
Smoke seal is very effective in preventing the spread of smoke through a fire rated door. A tight-fitting and latched fire rated door does not prevent smoke spread. Smoke seals should be provided to the top and sides of the fire rated door. 82 Subsection C7 - …
Tags:
Seal, Construction, Fire, Smoke, Resisting, Moses lake, T c fire resisting construction
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
Code of Practice for Fire Safety in Buildings 2011
www.bd.gov.hkPart F – Fire Safety Management . Section 1 – General . F1 Use of this Part 164 . F2 Performance Requirements for Fire Safety Management 164 . F3 Scope 164 . Section 2 – Fire Safety Management . F4 Fire Safety Management 166 . Section 3 – Maintenance Plan . F5 Maintenance Plan 168. Section 4 – Training Plan . F6 Training Plan 172
(E) Other Fire Resisting Products (e.g. fire shutter, etc)
www.bd.gov.hkBD-E010 Suzuki Shutter Suzuki Shutter Co. (HK) Ltd. 120 - UKAS Warrington Fire Research Service Ltd WFRC No. C124741 Supplement to WFRC No 120584 20/6/2002 1/7/2007 8/9/2005 BD-E011 Fibreglass Reinforced Plastic (FRP) Panel Architectural Precast GRC Ltd. 30 - The Singapore Accreditation Service PSB Corporation PSB Test Report Ref.
Central Data Bank List of Building Materials
www.bd.gov.hkIntumescent Coating Protection of steel columns up to 1 hr. FRP. BS 476: Parts 20 & 21: 1987 : N/A : The Loss Prevention Council : TE5944 : November 1986 : N/A : No-objection letter 18/01/2005 : issued in 1990. Required thickness of fire-resisting material should be in accordance with the test report no. TE5944. BD-FP 015 : Glulite Fire ...
Code of Practice
www.bd.gov.hkC2 Beams with Intermediate Buckling Restraints 57 C3 Beams with No Intermediate Buckling Restraints 59 C4 Continuously Restrained Beams 60 C5 Buckling Restraints 62 ANNEX D INSPECTION, MAINTENANCE AND REPAIR D1 General 64 D2 Deterioration and Failure of Glazing Systems 64 D2.1 Typical forms of deterioration 64 D2.2 Glass failure 64 D3 Maintenance Management 65
Technical Memorandum for Supervision Plans 2009
www.bd.gov.hk2.1 This Technical Memorandum supplements the provisions of the Buildings Ordinance governing the supervision of building works and street works. 2.2 This Technical Memorandum sets out the principles, requirements and operation of supervision plans. It deals in particular with:- (a) the principles for the preparation of supervision plans;
Code of Practice for Precast Concrete Contruction 2016
www.bd.gov.hk2.5.3 Handling and transportation ... Precast concrete elements should be designed and constructed in compliance with the Building (Construction) Regulations and other relevant codes of practice. The design method specified in this code of practice for the design of precast concrete elements is
Practice Note for Authorized Persons, Registered ...
www.bd.gov.hkHong Kong into a telecommunications, broadcasting and Internet hub in the Asia Pacific region. 2. To enable occupiers of a building to gain access to the full range of quality broadcasting, telecommunications and Internet services, the Telecommunications Authority has, under section 14 of the Telecommunications Ordinance, granted
Practice Note for Authorized Persons, Registered ...
www.bd.gov.hkmodelling, selection of geotechnical parameters and design water pressures, should be adopted. ... Alternatively, soil structure interaction analyses method may be carried out. 3.5.2 In soil structure interaction analyses, there could be a rapid increase in the maximum wall deflection/strut loads upon a small reduction in the wall
Modelling, Soil, Structure, Interactions, Soil structure interaction
Explanatory Notes to - Buildings Department
www.bd.gov.hkBS EN 1991-1-4. This enables shared use of future development work on these standards, and more direct use of data from these standards, where needed to supplement the Code. It may also assist with future convergence. Additional work was also carried out to resolve differences between these standards and to obtain better
Practice Note for Authorized Persons, Registered ...
www.bd.gov.hkrequirements for the design and construction of building, street, building works and street works. However, they do not contain reference to any specific prescriptive standard. 2. Appendix A lists those standards or technical criteria accepted by the Building Authority as complying with the performance requirements stipulated in the Regulations.
Related documents
How to ensure ‘Certifire’ Fire Door Certification is ...
firedoors.bwf.org.uk8. You can produce a FD30S or F60S ‘smoke control door’ but it MUST be fitted with the correct CE marked and Certifire Approved smoke seals. Please check the CF for the SEAL to confirm that it can be used. Take note of the threshold gaps required for smoke doors. 9.
DURATION ® HARMONY ® SUPERPAINT OPULENCE - …
images.sherwin-williams.com•Seals in odours from fire, smoke, and pets. •Seals in stains and graffiti Primes and seals in one coat. PRIME RX PEEL BONDING PRIMER •Seals surfaces and assures a smoother finish. •Saves time, money and labour with less sanding and scraping. •Goes on milky-white for ease of application and dries clear.
ADVICE NOTE FIRE SAFETY IN FLATS - ARMA
arma.org.ukA fire door set can only offer protection in limiting the spread of smoke and fire if the door seals are working effectively and if the door can fully close into the recess under the action of its door closer. The self-closing device should be capable of closing the door securely into its frame from
NFPA Code Requirements
assets.new.siemens.comSafety seals, tags, pressure gauge readings, HMIS Label. Fire Pumps NFPA 25 Weekly system procedures. Electric 10 min. Diesel 30 min. Alarm Systems NFPA 72, ... Fire Phones Heat Detectors All Smoke Detectors - Functional Fire - Gas and other detectors Interface Equipment Special Hazard Equipment Alarm Notification Devices
Combination Fire Smoke Damper Steel 3V Blades UL 555 1 ...
content.greenheck.comFire Damper Listing (#3225-0981:103) Leakage (Smoke) Damper Listing (#3230-0981:104) Model FSD-211 Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL 555 11⁄ 2 Hour Fire Resistance Rating Application Model FSD-211 is a combination fire smoke damper with 3V style blades. This model is designed for operation and dynamic ...
FIRE SAFETY LOG BOOK - irp-cdn.multiscreensite.com
irp-cdn.multiscreensite.comsmoke should be inspected to ensure that the fire and smoke resistance is being maintained i.e. no holes in walls and floors, no broken glazing, doors are not damaged and smoke seals touch the door and frame continuously, etc.
Seal, Fire, Smoke, Moses lake
Fire Doors Basic Guidance & Checklist - London Borough of ...
www.merton.gov.ukIntumescent fire and smoke seals For a door to work effectively, the door leaf must be free to move within the frame. In order to do this there must be a gap around the perimeter which may compromise the door’s ability to restrict the spread of fire. Intumescent seals are the strips set into the door or frame that swell up
Seal, Fire, Smoke, Moses lake
Fire and Life Safety Guidelines for Schools
esa.dc.govAll portable fire extinguishers must be checked monthly for obvious damage, broken seals, and to ensure that the gauge is in the operable range or, if not equipped with a gauge, for the proper weight. School-based personnel are responsible for monthly inspection of fire extinguishers. •