PARTS LIST MANUAL - Carrier

Container RefrigerationPARTS LIST MANUALForPrimeLINE 69NT40-561-200 to 29969NT40-561-500 to 599 PrimeLINE ONE 69NT40-565-200 to 29969NT40-565-500 to 599 Container Refrigeration UnitsT-362PL Rev LTM 2020 Carrier Corporation Printed in USA October 2020 PARTS LIST MANUALForPrimeLINE 69NT40-561-200 to 29969NT40-561-500 to 599 PrimeLINE ONE 69NT40-565-200 to 29969NT40-565-500 to 599 Container Refrigeration UnitsiT-362 PLTABLE OF CONTENTSPARAGRAPH INTRODUCTION .. REFRIGERANT .. CONFIGURATION IDENTIFICATION .. FEATURE DESCRIPTIONS.

PARTS LIST MANUAL For PrimeLINE 69NT40-561-200 to 299 69NT40-561-500 to 599 PrimeLINE ONE 69NT40-565-200 to 299 69NT40-565-500 to 599 Container Refrigeration Units. i T-362PL TABLE OF CONTENTS ... All information in this manual pertaining to R-513A is only applicable to 561-500 to

Tags:

  Manual, Lists, Content, Table of contents, Table, Part, Manual parts list

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of PARTS LIST MANUAL - Carrier

1 Container RefrigerationPARTS LIST MANUALForPrimeLINE 69NT40-561-200 to 29969NT40-561-500 to 599 PrimeLINE ONE 69NT40-565-200 to 29969NT40-565-500 to 599 Container Refrigeration UnitsT-362PL Rev LTM 2020 Carrier Corporation Printed in USA October 2020 PARTS LIST MANUALForPrimeLINE 69NT40-561-200 to 29969NT40-561-500 to 599 PrimeLINE ONE 69NT40-565-200 to 29969NT40-565-500 to 599 Container Refrigeration UnitsiT-362 PLTABLE OF CONTENTSPARAGRAPH INTRODUCTION .. REFRIGERANT .. CONFIGURATION IDENTIFICATION .. FEATURE DESCRIPTIONS.

2 OPTION DESCRIPTIONS .. ORDERING INSTRUCTIONS .. LETTER DESIGNATIONS .. 62 AIR EXCHANGE KIT, LOWER, NONE, HANDLE .. 83 UPPER FRESH AIR - VPS PANEL .. 104 UPPER FRESH AIR - BLANK PANEL .. 125 BACK PANEL ASSEMBLY .. 146 BOX PREP KIT .. 167 BULKHEAD PENETRATION - UPPER AIR EXCHANGE .. 188 CABLE ASSEMBLY .. 209 CABLE KIT .. 2210 CABLE RESTRAINT COMPONENTS .. 2411 COMPRESSOR ASSEMBLY .. 2612 COMPRESSOR TUBING .. 2813 CONDENSER .. 3014 CONDENSER FOR PRIMELINE ONE.

3 3615 CONDENSER FAN AND MOTOR .. 4016 WATER COOLED CONDENSER OPTION - TUBE-IN-SHELL .. 4217 WATER COOLED CONDENSER OPTION - BRAZED PLATE .. 4317 WATER COOLED CONDENSER OPTION - BRAZED PLATE .. 4418 CONTROLLER KIT .. 4619 CONTROLLER MODULE SECTION AND SOFTWARE CARDS .. 5020 CONTROLLER DOOR KIT, LATCH .. 5221 CONTROLLER DOOR KIT, SCREW .. 5622 DRAIN .. 5823 AUTOTRANSFORMER .. 6024 HEATERS .. 6425 EVAPORATOR FAN AND MOTOR .. 6626 EVAPORATOR TUBING AND COIL.

4 6827 FRAME KIT .. 7028 HUMIDISTAT KIT .. 7329 INTERROGATOR RECEPTACLE .. 7430 LABELS AND DECALS .. 7531 PANEL KIT .. 7632 REMOTE MONITORING UNIT (RMU) KIT .. 7733 USDA .. 7834 VACUUM RELIEF VALVE .. 7935 WIRING KIT .. 8036 HIGH VOLTAGE HARNESS .. 8437 LOW VOLTAGE HARNESS .. 8638 INTERROGATOR ACCESSORIES - DATALINE / DATAREADER .. 8839 TOOLS .. 903T-362 PLSECTION INTRODUCTIONThe Carrier Transicold PrimeLINE models 69NT40-561-200 to 299 and 69NT40-561-500 to 599 are units of light-weight aluminum frame construction, designed to be bolted on to the front of a container and serve as the con-tainer s front wall.

5 Forklift pockets are provided for unit installation and Carrier Transicold PrimeLINE ONE models 69NT40-565-200 to 299 and 69NT40-565-500 to 599 are unitsof lightweight aluminum frame construction, designed to be directly installed on-site onto a welded front wall of units are self-contained, all electric units, which include cooling and heating systems to provide precisetemperature control. The units are supplied with a complete charge of refrigerant and compressor lubricating oil,and are ready for operation upon installation.

6 The base unit operates on nominal 380/460 volt, 3-phase, 50/60 hertz (Hz) power. An optional autotransformermay be fitted to allow operation on nominal 190/230, 3-phase, 50/60 Hz power. Control system power is providedby a transformer which steps the supply power down to 18 and 24 volts, single controller is a Carrier Transicold Micro-Link 3 microprocessor. The controller operates automatically to selectcooling, holding or heating as required to maintain the desired set point temperature within very close limits. Theunit may also be equipped with an electronic temperature recorder.

7 The controller has a keypad and display forviewing or changing operating parameters. The display is also equipped with lights to indicate various modes REFRIGERANTP rimeLINE models 69NT40-561-200 to 299 and PrimeLINE ONE models 69NT40-565-200 to 299 are unitsdesigned to only be charged with R-134a models 69NT40-561-500 to 599 and PrimeLINE ONE models 69NT40-565-500 to 599 are R-513A-ready units. They are supplied with a complete charge of R-134a refrigerant. But, they are capable of being fieldconverted to R-513A refrigerant at a later date as requested by the unit owner.

8 R-513A is an azeotrope blend con-taining R-1234yf and R-134a. All information in this MANUAL pertaining to R-513A is only applicable to 561-500 to599 or 565-500 to 599 model units that have either been converted or are being converted to CONFIGURATION IDENTIFICATIONUnit identification information is provided on a plate located on the back wall of the condenser section. The plateprovides the unit model number, the unit serial number and the unit PARTS identification number (PID). The modelnumber identifies the overall unit configuration, while the PID number provides information on specific optionalequipment, factory provisioned to allow for field installation of optional equipment and differences in detailed FEATURE Control BoxUnits are equipped with an aluminum control box, and may be fitted with a lockable Temperature ReadoutThe unit is fitted with suction and discharge refrigerant temperature sensors.

9 The sensor readings may be viewedon the controller Pressure ReadoutThe unit is fitted with evaporator, suction, and discharge pressure transducers. The transducer readings may beviewed on the controller CompressorThe unit is fitted with either an R-134a or an R-513A scroll compressor equipped with suction and discharge ser-vice connections. To identify an R-513A-ready compressor in the field, a green dot is located on the top of the com-pressor on the DUV Condenser CoilThe unit is fitted with a C shape condenser EvaporatorThe evaporator section is equipped with an electronic expansion valve (EEV).

10 Evaporator Fan OperationUnits are equipped with three-phase evaporator fan motors. Opening of an evaporator fan internal protector willshut down the Plate SetEach unit is equipped with a tethered set of wiring schematics and wiring diagram plates. The plate sets areordered using a seven-digit base part number and a two-digit dash OPTION DESCRIPTIONSV arious options may be factory or field equipped to the base unit. These options are described in the following BatteryThe refrigeration controller may be fitted with standard replaceable batteries or a rechargeable battery battery packs may be fitted in the standard location or in a secure DehumidificationThe unit may be fitted with a humidity sensor.