Example: marketing

Passivent Background Ventilation Solutions

CI/SfB (57)Uniclass L753 October 2015 Background Ventilation Solutions FOR DOMESTIC people talk about Ventilation they think of the extract unit, taking theair out of the building. A Ventilation system is more than just extracting air,it also relies on the replacement of the stale air with fresh, clean you re using a Passive Stack system, a Mechanical Extract system oreven intermittent extract units, the building regulations call for a set amount ofbackground Ventilation for each Ventilation avoid condensation extraction of warm, moist air is not enough, it has to be inconjunction with input of fresh air, yet this is often over looked for a number ofdifferent reasons.

Fresh 100 3200mm 2 6000mm 2-6 Fresh TLF 2540mm 2 5000mm 2-7 Fresh 99H 3350mm 2 6000mm 2-7 ... Ultra Vent 2500 2500mm 2 1no x 13-17 x 165mm 235 x 25 x 10mm (TVUV25) 203 x 26.5 x 36mm ... with integral fly screen and fixing holes. Colour Bright White RAL 9016 as standard with

Tags:

  Screen, 2500mm, 3200mm

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Passivent Background Ventilation Solutions

1 CI/SfB (57)Uniclass L753 October 2015 Background Ventilation Solutions FOR DOMESTIC people talk about Ventilation they think of the extract unit, taking theair out of the building. A Ventilation system is more than just extracting air,it also relies on the replacement of the stale air with fresh, clean you re using a Passive Stack system, a Mechanical Extract system oreven intermittent extract units, the building regulations call for a set amount ofbackground Ventilation for each Ventilation avoid condensation extraction of warm, moist air is not enough, it has to be inconjunction with input of fresh air, yet this is often over looked for a number ofdifferent reasons.

2 The fresh air not only creates a fresh atmosphere, it also promotesair movement to ensure that air is circulated around the are many cases where people have a sufficiently working extract system yetstill experience condensation within properties, and the main reason is because ofinsufficient fresh offer a range of Background ventilators to enable fresh air to be input in toa building to ensure a healthy atmosphere and reduce the potential for condensationand and acoustic window and wall ventsPassivent standard window and wall vents are designed to allow air to enter thebuilding to provide the stated levels of Background Ventilation to meet therequirements of Building Regulations.

3 Geometric free areas are shown for ScottishBuilding Regulations. Passivent acoustic window and wall vents not only provide the stated levels ofbackground Ventilation , but also noise attenuation for buildings which may besituated where external noise could pose a disturbance to the Acoustic performancePageEquivalent areaFree areaSTANDARD WINDOW VENTSU ltra Vent2500 / 4000 / 5000mm22742 / 4465 / 5400mm2-3 Delta Vent and Grille1537 / 3074mm22000 / 4000mm2-4 Energy Saver Humidity Sensivitive3815mm24000mm2-4 ACOUSTIC WINDOW VENTSA coustic Energy Saver Humidity Sensitive 3815mm24000mm239dB5 Acoustic Low Profile1777 / 1600mm24400 / 4400mm240-42dB5 STANDARD WALL VENTSF resh 802220mm24000mm2-6 Fresh 902630mm26000mm2-6 Fresh

4 1003200mm26000mm2-6 Fresh TLF2540mm25000mm2-7 Fresh 99H3350mm26000mm2-7 ACOUSTIC WALL VENTSF resh 80dB2220mm24000mm250dB8 Fresh 90dB2630mm26000mm245dB8 Fresh 100dB3200mm26000mm242dB8 Fresh TLF-dB2540mm25000mm246dB9 Fresh 99 HdB3350mm26000mm245dB9 PRODUCT RANGE AND OVERVIEWW indow ventsWindow vents are incorporated through thehead of the window frame and available withmanual or automatic openings (humiditysensitive).Wall ventsWall vents are fitted through the wall andducted to an outside grille. Available withvarious manual control mechanisms orautomatic openings (humidity sensitive).

5 3 Air permeabilityUltra Vent 5000 achieves at 50Pa in the closed position when tested to BS EN 1026: tightnessUltra Vent 5000 achieves 1000Pa pressurewith no leakage in the closed position when tested to BS EN 1027: and DimensionsEquivalent areaProductEquivalent Slot size requiredDimensions (length x height x width)area(height x width)Internal VentExternal Canopy GrilleUltra Vent 25002500mm21no x 13-17 x 165mm235 x 25 x 10mm (TVUV25) 203 x x 36mm (TVUG25)Ultra Vent 40004000mm22no x 13-17 x 135mm350 x 25 x 10mm (TVUV4) 373 x x 36mm (TVUG5)Ultra Vent 50005000mm22no x 13-17 x 405 x 25 x 10mm (TVUV5) 373 x x 36mm (TVUG5)Scottish Building Regulations.

6 Geometric free areaProductGeometric Slot size requiredDimensions (length x height x width)free area(height x width)Internal VentExternal Canopy GrilleUltra Vent 25002742mm21no x 17 x 165mm235 x 25 x 10mm203 x x 36mmUltra Vent 40004465mm22no x 17 x 135mm350 x 25 x 10mm373 x x 36mmUltra Vent 50005400mm22no x 17 x x 25 x 10mm373 x x 36mmInternalVent withtwo stageopeningExternalCanopyGrilleSTANDARD WINDOW Vent and GrilleThrough frame window ventilator availablein three sizes comprises a controllableinternal ventilator and matching externalcanopy grille. Controlled flow of fresh air via two stage opening.

7 External canopy grille provides weather protection and insect ingress 3 sizes available providing 2500mm2,4000mm2 and 5000mm2equivalent areasand can be used to meet backgroundventilation requirements of BuildingRegulations throughout the UK andIreland. One of the smallest window ventilators onthe market providing up to 5000mm2equivalent area. Slim profile of 10mm for the vent. Suitable for a range of slot sizes from13mm to 17mm. Incoming air is directed upwards to avoiddraughts and discomfort. Suitable for PVCu, aluminium and timberwindows. Meets worst case requirements of BS 6375-1 for resistance to vent:Polyester powder coated aluminium with polymer end grille: Injection moulded polymerwith integral fly screen and fixing White RAL 9016 as standard with alternative colours available upon clauseProvide Background Ventilation to meetBuilding Regulations bymeans of windowventilators giving aminimum of*2500/4000/5000mm2of either *equivalent or *geometric free area of Ventilation (PassiventUltra Vent TVUV *25/4/5and Passivent Ultra GrilleTVUG *25/5).

8 Ventilators to provideupward directionalairflow and to meet worstcase requirements of BS 6375: Part 1 forresistance to available from Passivent Ltd, North Frith Oasts,Hadlow, Kent, TN11 9QU. Tel: 01732 850770, Fax: 01732 850949. as requiredInstalled inwindow Saver Humidity SensitiveAutomatic function dependent upon humiditylevels in the room. Can be used to meetbackground Ventilation requirements ofBuilding Regs throughout the UK andRepublic of Ireland. Minimises unnecessaryingress of cold air. No user input is required,and can help to reduce potential forcondensation.

9 Designed for use with UltraGrille (TVUG5) external canopy grille (seepage 3).Features Automatic, no user input. Uses no electricity or mechanical power. Directs airflow upwards avoiding draughtsand discomfort. Energy efficient, minimise heat and DimensionsProductVentilationSlot sizeLengthEquivalent area(height x width)TVES43815mm22no x 13 x : Injection moulded polystyreneColour: white, brown or black as standardOther RAL colours to us for at 20Pa: minimum 7m3/hr (closed to trickle), max 40m3 levels47% RH - 500mm2ventilation area65% RH - 3815mm2ventilation areaDepth Vent and GrilleControllable internal vent with matchingexternal grille.

10 Can be used to meetbackground Ventilation requirements ofBuilding Regulations throughout the UK and Republic of Ireland. Allows controlledingress of fresh air to aid healthy indoorenvironment and reduce potential Directs air upwards avoiding draughts and discomfort. Clearly marked, flush fitting slide control for simple operation. Meets worst case requirements of BS 6375: Part 1: 2000 for resistance to water penetration. Easy fitting due to location lugs. Optional pull cord operation where and DimensionsProductVentilation TrickleSlot sizeLengthEquivalent areaventilation(height x width)TVDV2 &TVDG21537mm2250mm21no x 13 x 165mm190mmTVDV4 &TVDG43074mm2500mm22no x 13 x : Injection moulded plasticColour.