Example: tourism industry

PENTAIR WATER Delavan, WI 53115 Pro-Source …

OWNER S MANUALPro-Source Steel pressure TanksMANUAL D UTILISATIONR servoirs sous pression en acier Pro-Source MANUAL DEL PROPIETARIOT anques de presi n de acero Pro-Source 20101000000173 (Rev. 8/2/10) PENTAIR WATER293 Wright StreetDelavan, WI 53115 Installation/Operation/PartsFor further operating, installation, or maintenanceassistance: Call 1-800-728-5551 English .. Pages 2-6 Installation/Fonctionnement/Pi cesPour plus de renseignements concernant l utilisation,l installation ou l entretien,Composer le1 (800) 728-5551 Fran ais.

General Information 3 GENERAL INFORMATION All tanks are factory pre-charged with air. When installing tank, adjust pre-charge to 2 PSI below pump cut-in pressure setting.

Tags:

  Pressure, Tanks, Pentair

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of PENTAIR WATER Delavan, WI 53115 Pro-Source …

1 OWNER S MANUALPro-Source Steel pressure TanksMANUAL D UTILISATIONR servoirs sous pression en acier Pro-Source MANUAL DEL PROPIETARIOT anques de presi n de acero Pro-Source 20101000000173 (Rev. 8/2/10) PENTAIR WATER293 Wright StreetDelavan, WI 53115 Installation/Operation/PartsFor further operating, installation, or maintenanceassistance: Call 1-800-728-5551 English .. Pages 2-6 Installation/Fonctionnement/Pi cesPour plus de renseignements concernant l utilisation,l installation ou l entretien,Composer le1 (800) 728-5551 Fran ais.

2 Pages 9-15 Instalaci n/Operaci n/PiezasPara mayor informaci n sobreel funcionamiento, instalaci n o mantenimiento de la bomba:Llame al 1-800-728-5551 Espa ol ..Paginas 16-22 Safety2 READ AND FOLLOW SAFETY INSTRUCTIONS!This is the safety alert you seethis symbol on your pump or in this manual,look for one of the following signal words and bealert to the potential for personal about hazards that will causeserious personal injury, death or major propertydamage if about hazards that can causeserious personal injury.

3 Death or major propertydamage if about hazards that will or cancause minor personal injury or property damage label NOTICE indicates special instructionswhich are important but not related to read and follow all safety instructions inthis manual and on safety labels in good condition. Replace missing or damaged safety FOR SAFEINSTALLATION ANDOPERATIONRead the Owner s Manual and Rules for SafeOperation and Installation Instructions to follow these Rules and Instructions couldcause serious bodily injury and/or property system according to local test WATER from well for purity before your local health department for testing installing or servicing your tank, BE SURE pump electric power source is SURE your pump electrical circuit is bleeder orifices.

4 Air volume controls orother air charging devices in existing prevent possible serious or fatalinjury and/or damage to equipment, system pres-sure must be less than 100 pounds per square inch(PSI) under any circumstances. Failure to followthis instruction can result in tank blowup. If sys-tem discharge pressure can exceed 100 PSI, installa relief valve capable of passing the full pump vol-ume at 100 pressure . Read owner smanual before attempting to install, operate, orservice this tank. To avoid possible equipment fail-ure, severe injury, and property damage, do notallow pump, tank, or piping system to WARRANTYPENTAIR WATER warrants to the original consumer purchaser ( Purchaser or You ) of the products listed below, that they will be free fromdefects in material and workmanship for the Warranty Period shown PeriodWater Systems Products whichever occurs first.

5 Jet pumps, small centrifugal pumps, 12 months from date of original installation, orsubmersible pumps and 18 months from date of manufacturerelated accessoriesPENTEK INTELLIDRIVE12 months from date of original installation, or18 months from date of manufacturePro-Source Composite Tanks5 years from date of original installationPro-Source Steel pressure Tanks5 years from date of original installationPro-Source Epoxy-Line Tanks3 years from date of original installationSump/Sewage/Effluent Products12 months from date of original installation, or18 months from date of manufactureOur warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improperinstallation.

6 Or improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power through aphase converter will void the warranty. Note also that three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of the recommended size or the warranty is only remedy, and PENTAIR WATER s only duty, is that PENTAIR WATER repair or replace defective products (at PENTAIR WATER schoice). You must pay all labor and shipping charges associated with this warranty and must request warranty service through theinstalling dealer as soon as a problem is discovered.

7 No request for service will be accepted if received after the Warranty Period hasexpired. This warranty is not WATER SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES,INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULARPURPOSE. THE FOREGOING WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION EXPRESSLY PROVIDED states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an impliedwarranty, so the above limitations or exclusions may not apply to You.

8 This warranty gives You specific legal rights and You may also haveother rights which vary from state to warranty supersedes and replaces all previous warranty WATER , 293 Wright St., Delavan, WI 53115 TPS series tanks are identicalto PS series tanks except forcolor. All parts are the Information 3 GENERAL INFORMATIONAll tanks are factory pre-charged with air. Wheninstalling tank, adjust pre-charge to 2 PSI belowpump cut-in pressure setting. To do this, bleed oradd air through valve on top of tank. NOTICE: Transport and install tank in vertical posi-tion ONLY!

9 NOTICE: Always set pre-charge with NO WATER pressure frequently with an accurate tirepressure gauge until correct pressure has beenreached. For correct pre-charge pressure settings,see Chart 1, below. CHART ITank Precharge Settings for use with PENTEKINTELLIDRIVE Variable Frequency DrivesSet the pressure tank s pre-charge to 70% of thesystem operating pressure . When using an externalset point as well as an internal set point, pre-chargethe tank to 70% of the lower set point of the applications may require a different percent-age when figuring the set point.

10 Refer to your PENTEK INTELLIDRIVE operator s manual for additional : Replace and tighten air valve cap if it isremoved for any reason. Failure to replace air capmay allow loss of air pressure and eventually leadto tank waterlogging and WATER cell failure. Pre-charged storage tanks can be connected together to increase the supply of usable WATER (drawdown). Two tanks of the same size will doublethe supply and three tanks will triple the Figures No. 1A and 1B for typical installationsof this kind. OPERATING CYCLE1. Tank nearly empty air expands filling areaabove vinyl WATER cell (Fig.)


Related search queries