Peppers Cable Glands LimitedStanhope Road, Camberley, Surrey, GU15 3BT United KingdomTelephone: +44 (0) 1276 64232 Facsimile: +44 (0) 1276 691752 Email: gland :- Type CR-U Croclock CR-U type Glands provide a Flameproof EExd compound filled barrier, a secondary weather seal on the outer sheath and an entry thread seal. Croclock CR-U type Glands maintain EExd Flameproof method of explosion protection; IP66, 68 to 100 metres and is deluge resistant. Peppers Cable Glands Limited 20082008 Catalogue Page 03 ATEX1479X - Ex Notified Body No. 0518 POCC GB 1356011 IECEx SIR GYJ06188X-60 C to +85 CZinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN)ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel)IEC Ex SIR Exd I & IIC Ex tD A21 IP68 CR-UB/20/M20 Sira 03 ATEX1479X Peppers GU15 3BT UK ГБ06c us Cl I Zn 1 AEx d IIC 4X EExd I & IIC Ex I M2 II 2 GDBrass CZ121 (CR-UB)316 Stainless Steel (CR-US)Inner LSOH compound Standard outer sheath seal is LSOH silicone, white (CR-U*)Entry thread seal: Red LSOH silicone eexd equipmentCR-U type Glands will maintain Flameproof Exd integrity when used with any unarmoured Cable : IEC60079-14:2002 Section Group Internal Ignition Source Enclosure Volume Wh

Peppers Cable Glands Limited Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom Telephone: +44 (0) 1276 64232 Facsimile: +44 (0) 1276 691752 Email: [email protected] Barrier Gland:- Type CR-U Croclock CR-U type glands provide a Flameproof EExd compound filled barrier, a secondary weather seal on the outer

Tags:

  Gland, Peppers, Cable, Peppers cable glands ltd

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Peppers Cable Glands Ltd - SafeExIT A/S

1 Peppers Cable Glands LimitedStanhope Road, Camberley, Surrey, GU15 3BT United KingdomTelephone: +44 (0) 1276 64232 Facsimile: +44 (0) 1276 691752 Email: gland :- Type CR-U Croclock CR-U type Glands provide a Flameproof EExd compound filled barrier, a secondary weather seal on the outer sheath and an entry thread seal. Croclock CR-U type Glands maintain EExd Flameproof method of explosion protection; IP66, 68 to 100 metres and is deluge resistant. Peppers Cable Glands Limited 20082008 Catalogue Page 03 ATEX1479X - Ex Notified Body No. 0518 POCC GB 1356011 IECEx SIR GYJ06188X-60 C to +85 CZinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN)ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel)IEC Ex SIR Exd I & IIC Ex tD A21 IP68 CR-UB/20/M20 Sira 03 ATEX1479X Peppers GU15 3BT UK ГБ06c us Cl I Zn 1 AEx d IIC 4X EExd I & IIC Ex I M2 II 2 GDBrass CZ121 (CR-UB)316 Stainless Steel (CR-US)Inner LSOH compound Standard outer sheath seal is LSOH silicone, white (CR-U*)Entry thread seal: Red LSOH silicone eexd equipmentCR-U type Glands will maintain Flameproof Exd integrity when used with any unarmoured Cable : IEC60079-14.

2 2002 Section Group Internal Ignition Source Enclosure Volume Which Zone Use CR-U GlandI, IIC, IIB, IIA YES Any Zone 1 or 2 YESGLAND MARKING(exAMPLe)INGReSS PROTeCTIONMATeRIALSOPeRATING TeMPeRATUReSTHReADSPLATINGOPTIONSCeRTIFI CATIONCeRTIFICATeAPPLICATIONO ther equipmentMining Equipment Group I, M2 Ignitable Dust, Zones 21 and 22@ 21 CConductor termination can be effected after 1 hourThe equipment can be energised after 4 hoursThe compound chamber can be inspected after 4 hoursCURING TIMeFor lead sheath cables the gland is fitted with a metallic continuity washer: Brass (CR-U2B); 316 Stainless Steel (CR-U2S)VARIATIONSNEPSI Exd IIC / Exe IIIncluding type No s:CRU*BSATEX I M2 II 2 GD, E Exd I & IICGOST R-Exd I & IICCSA Exd I & IIC 4X CSA A Exd IIC/A Exe II 4X, Class 1, Zone 1 IECEx Exd IIC / Exd IIP66 & IP68 @ 100 metres, Enclosure Type 4 XMeets the requirements of DTS01 1991 COMPLIANCe STANDARDEN 60079-0, EN 60079-1, EN 61241-0, EN 61241-1, IEC 60079-0, IEC 60079-1, IEC 61241-0 & IEC 61241-1 Page 2008 Catalogue Peppers Cable Glands Limited 2008 EXAMPLE PART NUMBERS ample: CR-UB K1/NP/20S/M20CR-U:CR-U - gland type**-*B - Material (Brass)K1 - Supplied complete with accessories (PVC Shroud)NP - Nickel plating20s - gland size with regards to Cable acceptance rangeM20 - Entry threadLocknut - Brass (ACBLN).

3 316 Stainless Steel (ACSLN)Earth Tag - Brass (ACBET), 316 Stainless Steel (ACSET)IP Washer - Nylon (ACNSW); Red Fibre (ACFSW)Serrated Lock Washer - 316 Stainless Steel (ACSSW), Galvanised Steel (ACGSW)Shroud - PVC (ACSPVC) gland and accessory kits:K1- includes gland , locknut, integral IP O ring & PVC shroudNote: Glands with non metric threads are supplied with flat IP gland Size does not necessarily equate to the entry thread size Integral entry thread seal option is not available for Glands with tapered entry threads. IP washers can be supplied if required Please note that dimensions (A) & (B) may differ for Glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions Unless otherwise stated ISO Metric entry threads have a pitch For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause of EN 50018.

4 2000 (clause IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads If CR-U type Glands are fitted into non-metallic enclosures they must be included within the earth circuit of the system The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation Full assembly instructions are supplied with Glands , the instructions must be read prior to installation and adhered to in fullIn order to maintain an IP rating greater than IP54, when used in a clearance hole, a suitable IP washer is supplies Cable Glands with parallel entry threads which conform to the flameproof threaded joint requirements of IEC 60079-1 and other equivalent standards. They usually incorporate a thread run out according to the available machining techniques, and will not have a full-form thread for the entire length.

5 Peppers will not be held responsible for clients installations where this has not been taken into accountllNOTES: gland SizeMetricentry Thread Length[a] Cable Inner Sheath / Cores [C]Max No. of CoresGland Seal RangeCable Outer Sheath [D] Min MaxNPT/BSPMax Across Corners[B]Shroud SizeEntry ThreadsMax Over CoresMax InnerSheathMax Protrusion Length 16 M20 1 2 or 3 4 16 7 L24 20s M20 1 2 or 3 4 16 8 L24 20 M20 1 2 or 3 4 16 14 EL30 25 M25 3 4 or 1 16 25 EL38 32 M32 1 or 11 4 16 50 EL46 40 M40 11 4 or 11 2 16 80 EL55 50s M50 2 16 100 EL65 50 M50 2 16 100 EL65 63s M63 21 2 19 120 EL80 63 M63 21 2 19 120 EL80 75s M75 3 19 140 EL90 75 M75 3 19 140 EL90 80 M80 x 2 3 or 31 2 25 160 L104 85 M85 x 2 3 or 31 2 25 180 L104 90 M90 x 2 31 2 or 4 25 200 L114 100 M100 x 2 31 2 or 4 25 220 L114 All Dimensions are in mm