Lovibond Water Analysis Tintometer Group Sewage Effluent Test Kit Perfect systems for the control and optimisation of water quality Marpol Annex IV Compliant Chemical Tests Full Suite of Tests to (55) Annex 26 BOD (Probable). Reduce the Risk of Inspection Failure Chemical Oxygen Demand (COD). Simple Step by Step Procedures Chlorine Rapid Results while at Sea Coliform and Enables On-Board Diagnostics to Maintain pH Value Water Quality Turbidity (Suspended Solids). DI 10 Portable Incubator No Refrigeration Required Logbook & Record Keeping Step by Step Method Book Video Training Guide Effluent Discharge at Sea Chemical Oxygen Demand & Technical Data Biochemical Oxygen Demand The environmental impact of the global economy is of ever growing concern. International and local Effluent discharge globally is routinely monitored regulations on industrial effluent discharge into our Method Most Probable Number for Chemical Oxygen Demand (COD) and rivers and oceans are essential if we are to protect Sample Size 100ml (10 x 10ml).

Lovibond® Water Analysis Tintometer® Group Sewage Effluent Test Kit www.lovibondwater.com Marpol Annex IV Compliant • Full Suite of Tests to MEPC.159(55) Annex 26 • Reduce the Risk of Inspection Failure

Tags:

  Optimisation

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Perfect systems for the control and optimisation of …

1 Lovibond Water Analysis Tintometer Group Sewage Effluent Test Kit Perfect systems for the control and optimisation of water quality Marpol Annex IV Compliant Chemical Tests Full Suite of Tests to (55) Annex 26 BOD (Probable). Reduce the Risk of Inspection Failure Chemical Oxygen Demand (COD). Simple Step by Step Procedures Chlorine Rapid Results while at Sea Coliform and Enables On-Board Diagnostics to Maintain pH Value Water Quality Turbidity (Suspended Solids). DI 10 Portable Incubator No Refrigeration Required Logbook & Record Keeping Step by Step Method Book Video Training Guide Effluent Discharge at Sea Chemical Oxygen Demand & Technical Data Biochemical Oxygen Demand The environmental impact of the global economy is of ever growing concern. International and local Effluent discharge globally is routinely monitored regulations on industrial effluent discharge into our Method Most Probable Number for Chemical Oxygen Demand (COD) and rivers and oceans are essential if we are to protect Sample Size 100ml (10 x 10ml).

2 Biochemical Oxygen Demand (BOD) as these give a our natural environment for future generations. direct indication on the ability of the treated water Sensitivity CFU / 100ml to alllow flora and fauna to survive. COD and Incubation 35 C / 24 Hours The IMO MARPOL regulates the impact of BOD consent under MEPC 159(55) Annex 26 are ocean-going vessels and has set clearly defined Coliform Colourless to Yellow 125mg/l and 25mg/l respectively. performance criteria for effluent treatment systems Test Fluorescence in UV. as part of (55) Annex 26. Vessels sailing into many sensitive ecosystems around the world Incubator are being closely monitored for effluent quality. Range 5 C > Ambient to 40 C. Polluting vessels can expect fines and experience Resolution C. lengthy delays at port. The Lovibond Sewage Operation 12V DC, 3 Amps Effluent Test Kit contains all of the tests required Power Adaptors 12V (in-car) + 100-240V. under (55) Annex 26: rapid, simple-to- Universal (UK, EU, USA).

3 Use test equipment, purposely designed for the Weight kg marine industry. Routine on-board monitoring of Size 246 x 215 x 162 mm both the treatment system and effluent quality will provide crucial, real time data to enable CE Conformity Yes correct process adjustment under the varying load conditions experienced while at sea. Chemical Oxygen Demand (COD). The COD equipment in the Lovibond Kit conforms Method Pre-dispensed Tube Coliform and to ISO 15705:2002. The method involves adding Sample Size 2ml a 2ml portion of sample to a pre-filled COD tube Sensitivity 0-150mg/l (55) Annex 26 stipulates effluent and heating it in the COD digester for 2 hours. Then the sample is cooled and placed in the MD Incubation 148 C / 2 Hours discharged into the ocean should have a thermo- tolerant Coliform count of less than 100cfu/100ml. 100 instrument, where the results can be read off Treatment systems achieve this with a combination directly in mg/l.

4 Suspended Solids (BOD). of heat and disinfection (eg Chlorine). The Method Turbidity Tube Lovibond Sewage Effluent Test Kit includes a Suspended Solids and BOD Sample Size up to 250ml simple test for enumerating Coliforms in effluent. Sensitivity SS 5-500mg/l 10%. A graduated turbidity tube is included for the Sensitivity BOD 10%. The method works by pouring a reagent sachet estimation of effluent BOD and Total Suspended into a 100ml sample of water, dividing this into 10. Solids as laboratory-based procedures for Disinfectant (Chlorine). jars and incubating for 24 hours. The portions that determining these parameters are not practical at change colour are then counted and compared Method CHECKIT Comparator sea. Land-based studies on effluent waters have Drop Test 0-30mg/l to the results chart for the concentration in shown good correlatin to laboratory methods using cfu/100ml. Sample Size 10ml - instant result this simple device.

5 Sensitivity Cl2 0-30mg/l Cl2 Tests are carried out by filling the tube with effluent whilst looking down through the unit. pH Value When the cross on the base disappears from view, the value that corresponds to the fill level Method Test Strip of the tube is recorded. BOD can be determined Sample Size 5ml by using a calculation from the Suspended Solids Resolution pH - 10 measurement: Suspended Solids Consent = 35mg/l BOD Consent = 25mg/l Ordering Information P/N Description 56K025201 Sewage Effluent Test Kit DI 10 Portable Incubator Accessories 56B001425 Test Pack The coliform and tests require incubation at 35 C to give an accurate result. The Lovibond DI 56M000701 DI 10 Incubator 10 unit is a compact, robust, digital device that 276120 MD 100 COD Photometer operates at 12V and is supplied with universal 2420720 COD Vials (pk25). power connectivity (UK, EU, USA). Excellent temperature stability is achieved with fan-assisted 56A010801 Turbidity Tube heating.

6 Chlorine and pH 56R005290 Chlorine Test Pack The Tintometer Ltd 56S001090 pH Test Strips Chlorine is extensively used for disinfection of Lovibond House effluent as part of the full processing. Chlorine Solar Way, Solstice Park consent is in final effluent with a pH. Amesbury, Wiltshire, SP4 7SZ range of pH Tests are included to monitor References Tel.: +44 (0)1980 664800 both parameters. Low and high range Chlorine The Marine Environment Protection Committee: Fax.: +44 (0)1980 625412 procedures are included to monitor levels Annex VI. (55) Annex 26. throughout the process. International Organisation for Standardisation, ISO15705:2002. Lovibond and Tintometer are Registered Trade Marks of The Tintometer Group. All translations and transliterations of LOVIBOND & TINTOMETER are asserted as Trade Marks of The Tintometer . Group. Registered Office: Lovibond House, UK. Registered in England No. 45024. Errors and Omissions Excepted - Content subject to alterations without notice.