Transcription of PFM 200N series - EM Test
1 DATA SHEET > PFM 200n series > 20171028 PFM 200n SERIESAUTOMOTIVE POWER FAIL SIMULATOR FOR OEM LV 124 ANDLV 148 AND OTHER MANUFACTURER STANDARDSFOR tests ACCORDING TO ..> LV 123> OEM LV 124 (2013-02)> LV 148> OEM LV 148> BMW GS 95024-2-1> BMW GS 95026> MBN LV 124-1> VW 80000> GMW 3172> Chrysler CS-11979> Cummins 14269 (982022-026)> Fiat > Hyundai/Kia ES 95400-10, Rev. D> Iveco 16-2103 (2010)> Nissan 28401 NDS 02> PSA B21 7110> Renault > Toyota TSC7203G> Volvo STD 515-0003> many other automotive standardsPFM 200n series - THE UNIQUE AUTOMOTIVE POWER FAIL SIMULATOR FOR LV 124 / LV 148 AND MICROINTERRUPTIONS ASPER MANUFACTURER STANDARDSThe PFM and PFM 200N200 have been designed to fully meet the requirements for E10, E13 and E14 of the LV124 and the E48-09 of the LV 148.
2 It also allows to perform microinterruptions with fast rise/fall time of as low as 200ns asrequired by GMW 3172, sec. The PFM 200n series includes a switch for the power supply line from 100 mA to 200A and a separate switch in the groundreturn path. These switches can support very high inrush currents up to several hundreds of Amp res. For signal- and data lines an additional 16 channel switch is included with current rating from 100 uA to 2 A per >Switch for Power supply (100 A / 200 A) andsignal/data lines (2 A)>Pulses E10 and E13 of the LV 124/LV 148 standard>Bidirectional current direction>Separate switch in the ground line>Rise/fall time less than 200nsAPPLICATION EM TEST > PAGE 1/4 DATA SHEET > PFM 200n series > 20171028 TECHNICAL DETAILSMODELSMODELSPFM current 100 mA to 100 APFM 200N200 DUT current 100 mA to 200 ATECHNICAL DETAILSPOWER LINE SWITCHS witch2 Switches in the circuit- DC+ Power line- DC- Ground lineDUT voltage 100 VDCDUT current100 mA to 100 A, 200 A@ 25 CCurrent directionBidirectionalSwitching time< 200 ns (rise/fall time)
3 Repetition rate10 s - 1 hDrop duration1 s - 1 hPeak current400 A for 200 ms1,350 A for 1 msautomatic switch-off if I > 1,350 ASafetyShort circuit protectionSWITCH FOR SIGNAL- AND DATALINE SWITCHC hannels16 independ switched linesDUT voltageMax. 40 VDCDUT current100 A to 2 A, per channel@ 25 CCurrent directionBidirectionalSwitching time< 1 s (rise/fall time)Repetition rate500 s - 1 hDrop duration1 s - 1 hBandwidth50 MHz / 3 dBPeak current5 A for 200 msSafetyShort circuit protectionConnectorPHOENIX, DFMC connector, mm2,Push-in-spring cage connectionTECHNICAL DETAILSGENERAL SWITCHS witch ImpedancePower lines: < 50 mOhm Data lines.
4 < 500 mOhmInternal switchShort circuit switch (DC+ to DC-),impedance <100 mOhm)Internal switch100 mOhm, per LV 124 Internal switchLowInternal switchHighTRIGGERT rigger OutBNC Plug at the front panel,Automatic release of the eventsTrigger for oscilloscope, negative slope 15 VTrigger InBNC Plug at the front panel,External release of a single eventPull downPROTECTIONDC InputprotectionMax. voltage 100 V,Clamped > 100 VDCData InputprotectionMax. voltage 40 V,Clamped > 40 VDCO vertemperatureNTC measurement on each mosfetswitchOvercurrentOn each mosfet switch electronicprotectionCurrentmeasurementOv erload measured at outputINTERFACEF rame busControl cable to AutoWaveMonitor OutputDUT out, differential,BNC plug on front panelRatio 1:20 SUITABLE BUS SYSTEMS FOR DATALINEBus systems- Low Speed Can 100 kbit- High Speed Can 500 kbit- LIN Bus 19200 Baud- FlexRay 10 Mbit.
5 EM TEST > PAGE 2/4 DATA SHEET > PFM 200n series > 20171028 TECHNICAL DETAILSGENERAL DATAGENERAL DATAD imensions19"/3 HU, 448 mm x 536 mm x 154 mmWeightapprox. kgSupply voltage100 V - 265 VAC, 50/60 HzFuses2 x 2 ATReferencetemperature23 C 5 CTemperature10 C to 35 CHumidity25 % to 75 %, non condensingAtmosphericpressure86 kPa (860 mbar) to 106 kPa (1 060mbar)OPTIONSCALIBRATION KITCA LV 124 Calibration Kit for PFM LV Kit for PFM 200N200 CALIBRATIONLV124 CalibrationCalibration kit for pulseverification,low inductive resistors,Powerlines:CA LV124-P1 RCA LV124-P100 RDatalines: For test 2 linesCA LV124-D1 RCA LV124-D1000 RCA LV124-P1 RPower line Ohm 1 %,U max.
6 : 12 V,P max.: 30 WP peak: 150 W max., 1 sCA LV124-P100 RPower line Ohm 1 %,U max.: 100 V,P max.: 30 WP peak: 100 W max., 1 sCA LV124-D1 RData line Ohm 1 %,U max.: V,P max.: 1 W,P peak: 4 W max., 1 sCA LV124-D1000 RData line calibration1000 Ohm 1 %,U max.: V,P max.: 1 WP peak: 4 W max., 1 EM TEST > PAGE 3/4 DATA SHEET > PFM 200n series > 20171028 COMPETENCE WHEREVERYOU ARECONTACT EM TEST DIRECTLYS witzerlandAMETEK CTS GmbH > Sternenhofstra e 15 > 4153 Reinach > SwitzerlandPhone +41 (0)61 204 41 11 > Fax +41 (0)61 204 41 00 Internet: > E-mail: CTS Europe GmbH > Customer Care Center EMEA > L nener Stra e 211> 59174 Kamen > GermanyPhone +49 (0) 2307 26070-0 > Fax +49 (0) 2307 17050 Internet: > E-mail: CTS Europe GmbH > Biuro w Polsce > ul.
7 Twarda 44 > 00-831 Warsaw >Poland Phone +48 (0) 518 643 12 Internet: > E-mail: / CanadaAMETEK CTS US > 52 Mayfield Ave > Edison > NJ 08837 > USAP hone +1 732 417 0501 Internet: > E-mail: ChinaAMETEK Commercial Enterprise (Shanhai) Co. Ltd.> Beijing Branch> Western Section, 2nd floor> Jing Dong Fang Building (B10)> ChaoyangDistrict>Beijing, China, 100015 Phone +86 10 8526 2111 > Fax +86 (0)10 82 67 62 38 Internet: > E-mail: of KoreaEM TEST Korea Limited > #405 > WooYeon Plaza > #986-8 > YoungDeok-dong >Giheung-gu > Yongin-si > Gyeonggi-do > KoreaPhone +82 (31) 216 8616 > Fax +82 (31) 216 8616 Internet: > E-mail: Singapore Pte.
8 Ltd > No. 43 Changi South Avenue 2 > 04-01 Singapore48164 Internet: > E-mail: BritainAMETEK GB > 5 Ashville Way > Molly Millars Lane > Wokingham > BerkshireRG41 2 PL > Great BritainPhone +44 845 074 0660 Internet: about scope of delivery, visual design and technical data correspond with the state of development at time of release. Subject tochange without further EM TEST > PAGE 4/4