Example: stock market

Pilot Valves and Nema 4 Enclosures - piiny.com

Clean Air SystemsPilot Valves and Nema 4 Enclosures2 Copyright by Tyco International Valves & Encs 06/08 Goyen Controls Co Pty Ltd reserves the right to change product designs and specifications without SpecificationQ Series Solenoid Solenoid used in the remote or integral actuation of dust collector diaphragm or Pilot forAll integrally piloted Goyen dustcollector diaphragm Valves , RCA3 Dseries Pilot Valves and Pilot valveenclosures, and 3DS Pilot solenoid over ferrule tube. Ensureterminals are on top. For QT and QFtype solenoids ensure nylon washer isin place.

Technical Specification - RCA3D Remote Pilot Order Code and Electrical Characteristics Model Connection Type Protection Class Voltage Power 3D0-300 DIN 43650A IP64 200/240V 50/60Hz 23.1 VA

Tags:

  Pilots, Enclosure

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Pilot Valves and Nema 4 Enclosures - piiny.com

1 Clean Air SystemsPilot Valves and Nema 4 Enclosures2 Copyright by Tyco International Valves & Encs 06/08 Goyen Controls Co Pty Ltd reserves the right to change product designs and specifications without SpecificationQ Series Solenoid Solenoid used in the remote or integral actuation of dust collector diaphragm or Pilot forAll integrally piloted Goyen dustcollector diaphragm Valves , RCA3 Dseries Pilot Valves and Pilot valveenclosures, and 3DS Pilot solenoid over ferrule tube. Ensureterminals are on top. For QT and QFtype solenoids ensure nylon washer isin place.

2 Slide clip onto Pilot iron voltage supplied to solenoid iswithin -10% and +15% of the solenoidrated :PA-6C-frame: Mild steel zinc passivatedBobbin:PA-6 Insulation class:B/130 CRating: Non-continuous use onlyClip: Mild steel (mechanically plated)OperationRecommended on time range: 50-500msRecommended time between pulses:1 minute or greaterApprovals C-Tick EMC (89/336/CE)OptionsNoneSpare PartsNone availableDimensions and Weights(Dimensions in mm) lbQRQDQT2 QFFlying leads, QFDIN 43650A connection, QRConduit entryconnection, QDScrews/spadeterminals, QT23 Copyright by Tyco International Valves & Encl 06/08 Goyen Controls Co Pty Ltd reserves the right to change product designs and specifications without Specification - Q Series SolenoidOrder Code and Electrical CharacteristicsCode K-TypeConnection TypeClassVoltageInrush mAHold mAPowerColour300 QRDIN 43650 AIP64200/240V 50/60Hz148/143105 VAGrey301 QRDIN 43650 AIP64100/120V 50/60Hz234/255180 VAGrey302 QRDIN 43650 AIP6424V 50/60 Hz1338/1096963 VAGrey303 QRDIN 43650 AIP64110 VDC21221224 WGrey304 QRDIN 43650 AIP6448 VDC42942920 WGrey305 QRDIN 43650 AIP6424

3 VDC87387320 WGrey306 QRDIN 43650 AIP6412 VDC1644164420 WGrey310 QDConduit ( )IP31200/240V 50/60Hz148/143105 VAGreen311 QDConduit ( )IP31100/120V 50/60Hz234/255180 VAGreen312 QDConduit ( )IP3124V 50/60 Hz1338/1096963 VAGreen313 QDConduit ( )IP3124 VDC87387320 WGreen314 QDConduit ( )IP3112 VDC1644164420 WGreen320 QDConduit ( " NPSC)IP31200/240V 50/60Hz148/143105 VAGreen321 QDConduit ( " NPSC)IP31100/120V 50/60Hz234/255180 VAGreen322 QDConduit ( " NPSC)IP3124V 50/60 Hz1338/1096963 VAGreen323 QDConduit ( " NPSC)IP3124 VDC87387320 WGreen324 QDConduit ( " NPSC)IP3112 VDC1644164420 WGreen330QT2 Screw / spadeN/A200/240V 50/60Hz148/143105 VAPurple331QT2 Screw / spadeN/A100/120V 50/60Hz234/255180 VAPurple332QT2 Screw / spadeN/A24V 50/60 Hz1338/1096963 VAPurple333QT2 Screw / spadeN/A240 VDC949424 WPurple334QT2 Screw / spadeN/A110 VDC21221224 WPurple335QT2 Screw / spadeN/A48 VDC42942920 WPurple336QT2 Screw / spadeN/A24 VDC87387320 WPurple337QT2 Screw / spadeN/A12 VDC1644164420 WPurple338QT2 Screw / spadeN/A12 VDC2500250030 WOrange340 QFFlying leadsIP64200/240V 50/60Hz1338/1096963 VAPurple341 QFFlying leadsIP64100/120V 50 VAPurple342

4 QFFlying leadsIP6424V 50/60 VAPurple343 QFFlying leadsIP6424 VDC87387320 WPurple344 QFFlying leadsIP6412 VDC1644164420 WPurple348 QFFlying leadsIP6412 VDC2500250030 WOrange349 QFFlying leadsIP6436V VAPurpleTechnical SpecificationRCA3D Remote PilotRemote solenoid Pilot valve to control the actuation ofdust collector diaphragm forAll Goyen dust collector diaphragm Pilot mounting hole in panel to ( "). Panel thicknessmust exceed ( "). Ensureo-ring is in place before tighteninglocknut. Preferably, install Pilot valveswith solenoid on top. For reliableoperation, ensure supply voltage iswithin -10% and +15% of ratedsolenoid voltage.

5 Replace componentswithin 1 million cycles (refer to Spare Parts)ConstructionBody:Aluminium (diecast)Ferrule: 304 SSArmature:430FR SSSeals:NitrileLocknut: Mild steel zinc passivatedScrews: 302 SSClip: Mild steel (plated)OperationRecommended on time range: 50-500msRecommended time between pulses:1 minute or greaterApprovals C-Tick EMC (89/336/CE)OptionsNoneDimensions and Weights(Dimensions in mm and inches)SeriesWeightRCA3D0, RCA3D1 (no solenoid) lbProduct PerformanceFlowMaximum WorkingMinimum Cv860 kPa0 kPa-40 C82 CAir Kv125 psi0 psi-40 F180 Finert gasSpare PartsK0380 Replacement seal, armature.

6 Spring & ferrule As above in withflying leadconnectionRCA3D withspadeconnectionRCA3D withconduit entryconnectionRCA3D with DIN43650A connection4 Copyright by Tyco International Valves & Encs 06/08 Goyen Controls Co Pty Ltd reserves the right to change product designs and specifications without Specification - RCA3D Remote PilotOrder Code and Electrical CharacteristicsModelConnection TypeProtection ClassVoltagePower3D0-300 DIN 43650 AIP64200/240V 50 VA3D0-301 DIN 43650 AIP64100/120V 50 VA3D0-302 DIN 43650 AIP6424V 50/60 VA3D0-303 DIN 43650 AIP64110 VDC24 W3D0-304 DIN 43650 AIP6448 VDC20 W3D0-305 DIN 43650 AIP6424 VDC20 W3D0-306 DIN 43650 AIP6412 VDC20 W3D0-310 Conduit ( )IP31200/240V 50 VA3D0-311 Conduit ( )IP31100/120V 50 VA3D0-312 Conduit ( )IP3124V 50/60 VA3D0-313 Conduit ( )IP3124 VDC20 W3D0-314 Conduit ( )IP3112 VDC20 W3D0-320 Conduit (1/2" NPSC)IP31200/240V 50 VA3D0-321 Conduit (1/2" NPSC)IP31100/120V 50 VA3D0-322 Conduit (1/2" NPSC)IP3124V 50/60 VA3D0-323 Conduit (1/2" NPSC)IP3124 VDC20 W3D0-324 Conduit (1/2" NPSC)

7 IP3112 VDC20 W3D0-340 Flying LeadIP64200/240V 50 VA3D0-341 Flying LeadIP64100/120V 50 VA3D0-342 Flying LeadIP6424V 50/60 VA3D0-343 Flying LeadIP6424 VDC20 W3D0-344 Flying LeadIP6412 VDC20 W3D1-300 DIN 43650 AIP64200/240V 50 VA3D1-301 DIN 43650 AIP64100/120V 50 VA3D1-302 DIN 43650 AIP6424V 50/60 VA3D1-303 DIN 43650 AIP64110 VDC24 W3D1-304 DIN 43650 AIP6448 VDC20 W3D1-305 DIN 43650 AIP6424 VDC20 W3D1-306 DIN 43650 AIP6412 VDC20 W3D1-310 Conduit ( )IP31200/240V 50 VA3D1-311 Conduit ( )IP31100/120V 50 VA3D1-312 Conduit ( )IP3124V 50/60 VA3D1-313 Conduit ( )IP3124 VDC20 W3D1-314 Conduit ( )IP3112 VDC20 W3D1-320 Conduit (1/2" NPSC)IP31200/240V 50 VA3D1-321 Conduit (1/2" NPSC)IP31100/120V 50 VA3D1-322 Conduit (1/2" NPSC)IP3124V 50/60 VA3D1-323 Conduit (1/2" NPSC)IP3124 VDC20 W3D1-324 Conduit (1/2" NPSC)

8 IP3112 VDC20 W3D1-340 Flying LeadIP64200/240V 50 VA3D1-341 Flying LeadIP64100/120V 50 VA3D1-342 Flying LeadIP6424V 50/60 VA3D1-343 Flying LeadIP6424 VDC20 W3D1-344 Flying LeadIP6412 VDC20 W5 Copyright by Tyco International Valves & Encl 06/08 Goyen Controls Co Pty Ltd reserves the right to change product designs and specifications without Specification3DS Pilot ValvePilot valve with integral silencer and dust shroud tomount directly to dust collector diaphragm forRCAC20T3, RCAC20ST3,RCAC20DD3, RCAC20FS3,RCAC25T3, RCAC25DD3,RCAC25FS3 dust collector Valves o-ring is in place on diaphragmvalve cover.

9 Gripping the shroud, handtighten 3DS Pilot valve onto cover ofdiaphragm valve. For reliableoperation, ensure supply voltage iswithin -10% and +15% of ratedsolenoid voltage. Solenoid is free torotate on Pilot valve. 3DS thread willsuit 1/8 BSP T, 1/8 BSP P and 1/8 NPTports. Replace Pilot components within1 million cycles (refer to Spare Parts).ConstructionBody:AI 2011-T3 Ferrule:302 SSArmature:430FR SSEncapsulation: PA-6 Insulation: Class B/130 CSeals:NitrileShroud: PA-6 OperationRecommended on time range: 50-500msRecommended time between pulses:1 minute or greaterApprovals C-Tick EMC (89/336/CE)OptionsNoneDimensions and Weights(Dimensions in mm)

10 Kg / lb3DS-300 to kg / lb3DS-310 to kg lb3DS-300 to 3DS-3063DS-310 to 3DS-324 Product PerformanceFlowMaximum WorkingMinimum Cv860 kPa0 kPa-40 C82 CAir Kv125 psi0 psi-40 F180 Finert gasSpare PartsK0380 Nitrile replacement seal, armature, spring and As above in viton to 3DS-3063DS-310 to3DS-3246 Copyright by Tyco International Valves & Encs 06/08 Goyen Controls Co Pty Ltd reserves the right to change product designs and specifications without Specification - 3DS Pilot Valve7 Copyright by Tyco International Valves & Encl 06/08 Goyen Controls Co Pty Ltd reserves the right to change product designs and specifications without Code and Electrical CharacteristicsModelConnection TypeProtection ClassVoltagePower3DS-300 DIN 43650 AIP64200/240V 50 VA3DS-301 DIN 43650


Related search queries