DIMENSIONAL CATALOG. ABS-DWV pipe and Fittings PVC-DWV pipe and Fittings PVC Sewer pipe PVC Schedule 30 DWV Thin Wall in. pipe and Fittings (Updated March 23, 2011). DWV. DC-DWV 1977-2011 Charlotte pipe and Foundry Company Plastic DWV pipe and Fitting Dimensions All products manufactured by Charlotte pipe and Foundry Company are proudly made in the Table of Contents Page ABS Foam Core Schedule-40 DWV. pipe PVC Foam Core Schedule-40 DWV. pipe RePVC Schedule 40 DWV pipe PVC Schedule 40 DWV pipe D 3034 PVC Sewer pipe PVC D 2729 Sewer and Drain pipe PVC and ABS DWV Fittings PVC Thin Wall Sch. 30 pipe PVC Thin Wall Sch. 30 Fittings This catalog accurately reflects dimensional information to the best of our knowledge. If the Dimensions on your job are critical, please verify dimensional information with our factory. This dimensional catalog accurately reflects our product line at the time the catalog was printed. However, we add and delete items on an ongoing basis to better serve our customers.

Plastic DWV Pipe and Fitting Dimensions All products manufactured by Charlotte Pipe and Foundry Company are proudly made in the U.S.A.

Tags:

  Fitting, Plastics, Dimensions, Pipe, Plastic dwv pipe and fitting dimensions

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Plastic DWV Pipe and Fitting Dimensions

1 DIMENSIONAL CATALOG. ABS-DWV pipe and Fittings PVC-DWV pipe and Fittings PVC Sewer pipe PVC Schedule 30 DWV Thin Wall in. pipe and Fittings (Updated March 23, 2011). DWV. DC-DWV 1977-2011 Charlotte pipe and Foundry Company Plastic DWV pipe and Fitting Dimensions All products manufactured by Charlotte pipe and Foundry Company are proudly made in the Table of Contents Page ABS Foam Core Schedule-40 DWV. pipe PVC Foam Core Schedule-40 DWV. pipe RePVC Schedule 40 DWV pipe PVC Schedule 40 DWV pipe D 3034 PVC Sewer pipe PVC D 2729 Sewer and Drain pipe PVC and ABS DWV Fittings PVC Thin Wall Sch. 30 pipe PVC Thin Wall Sch. 30 Fittings This catalog accurately reflects dimensional information to the best of our knowledge. If the Dimensions on your job are critical, please verify dimensional information with our factory. This dimensional catalog accurately reflects our product line at the time the catalog was printed. However, we add and delete items on an ongoing basis to better serve our customers.

2 Please refer to our current list price sheets for an accurate listing of items offered. Charlotte pipe products are manufactured to the applicable ASTM. standard. Charlotte pipe and Foundry cannot accept responsibility for the performance, dimensional accuracy, or compatibility of pipe , fittings, gaskets, or couplings not manufactured or sold by Charlotte pipe and Foundry. Charlotte pipe and RePVC are registered trademarks of Charlotte pipe and Foundry Company. pipe Data ABS Foam Core pipe ABS Schedule 40 DWV pipe (For Non-Pressure Applications). ABS SCHEDULE 40 FOAM CORE (BLACK) PLAIN END ASTM F 628. MIN. WT. PER. PART NO. NOM. SIZE UPC # QTY. PER AVG. OD WALL 100 FT. 611942- SKID (IN.) (IN.) (LBS.). ABS 3112 11 2 x 10' 03132 2590 ABS 3112 11 2 x 20' 03133 5180 ABS 3200 2 x 10' 03134 1670 ABS 3200 2 x 20' 03135 3340 ABS 3300 3 x 10' 03136 750 ABS 3300 3 x 20' 03137 1500 ABS 3400 4 x 10' 03138 480 ABS 3400 4 x 20' 03139 960 ABS 3600 6 x 10' 03140 200 ABS 3600 6 x 20' 03141 400 NSF Listed.

3 Meets All Requirements of ASTM F 628. Testing with or use of compressed air or gas in PVC / ABS. / CPVC pipe or fittings can result in explosive failures and cause severe injury or death. NEVER test with or transport/store compressed air or gas in PVC / ABS / CPVC. pipe or fittings. NEVER test PVC / ABS / CPVC pipe or NOT FOR PRESSURE fittings with compressed air or gas, or air Do not use PVC / ABS cellular core (foam core) pipe for over water boosters. ONLY use PVC / ABS / CPVC pipe for water pressure applications. The use of cellular core pipe in or approved chemicals. pressure applications may result in system failure and Refer to warnings in PPFA User Bulletin property damage. 4-80 and ASTM D 1785. 4. pipe Data PVC Foam Core pipe PVC Schedule 40 DWV pipe (For Non-Pressure Applications). PVC SCHEDULE 40 FOAM CORE (WHITE) PLAIN END ASTM F 891. MIN. WT. PER. PART NO. NOM. SIZE UPC # QTY. PER AVG. OD WALL 100 FT. 611942- SKID (IN.) (IN.) (LBS.). PVC 4112 11 2 x 10' 04178 1720 PVC 4112 11 2 x 20' 04177 3440 PVC 4200 2 x 10' 04174 990 PVC 4200 2 x 20' 04173 1980 PVC 4300 3 x 10' 03934 1040 P.

4 PVC 4300 3 x 20' 03935 920 V. PVC 4400 4 x 10' 03936 600 C. - PVC 4400 4 x 20' 03937 1200 D. PVC 4600 6 x 10' 03938 280 W. PVC 4600 6 x 20' 03939 560 V. PVC 4800 8 x 20' 03941 360 P. PVC 4910 10 x 20' 03942 220 I. P. PVC 4912 12 x 20' 03943 120 E. PVC SCHEDULE 40 FOAM CORE (WHITE) BELL-END. MIN. WT. PER. PART NO. NOM. SIZE UPC # QTY. PER AVG. OD WALL 100 FT. 611942- SKID (IN.) (IN.) (LBS.). PVC 4300B 3 x 20' 04782 920 PVC 4400B 4 x 10' 04783 540 PVC 4400B 4 x 20' 04784 1080 PVC 4600B 6 x 20' 04786 480 NOTE: When ordering, please specify plain end or bell end. NSF Listed. Meets All Requirements of ASTM F 891. Testing with or use of compressed air or gas in PVC / ABS. / CPVC pipe or fittings can result in explosive failures and cause severe injury or death. NEVER test with or transport/store compressed air or gas in PVC / ABS / CPVC. pipe or fittings. NEVER test PVC / ABS / CPVC pipe or NOT FOR PRESSURE fittings with compressed air or gas, or air Do not use PVC / ABS cellular core (foam core) pipe for over water boosters.

5 Pressure applications. The use of cellular core pipe in ONLY use PVC / ABS / CPVC pipe for water pressure applications may result in system failure and or approved chemicals. Refer to warnings in PPFA User Bulletin property damage. 4-80 and ASTM D 1785. 5. pipe Data RePVC DWV pipe RePVC is a registered trademark of Charlotte pipe and Foundry Company. PVC Schedule 40 DWV pipe with Recycled Content (For Non-Pressure Applications). PVC SCHEDULE 40 (WHITE) PLAIN END ASTM F 1760. MIN. WT. PER. PART NO. NOM. SIZE UPC # QTY. PER AVG. OD WALL 100 FT. 611942- SKID (IN.) (IN.) (LBS.). PVC 15112 11 2 x 20' 11744 3440' PVC 15200 2 x 20' 11745 1980' PVC 15300 3 x 20' 11746 920' PVC 15400 4 x 20' 11748 1200' PVC 15600 6 x 20' 11749 560' PVC 15800 8 x 20' 11984 360' .322 NSF Listed. Meets All Requirements of ASTM D 4396 and ASTM F 1760. All products manufactured by Charlotte Testing with or use of compressed air or gas in PVC / ABS. pipe and Foundry Company are proudly / CPVC pipe or fittings can result in explosive failures and cause severe injury or death.

6 Made in the NEVER test with or transport/store compressed air or gas in PVC / ABS / CPVC. pipe or fittings. NEVER test PVC / ABS / CPVC pipe or fittings with compressed air or gas, or air over water boosters. ONLY use PVC / ABS / CPVC pipe for water or approved chemicals. Refer to warnings in PPFA User Bulletin 4-80 and ASTM D 1785. 6. pipe Data PVC Schedule 40 DWV pipe PVC Schedule 40 DWV pipe PVC SCHEDULE. PVC SCHEDULE 40. 40 (WHITE). (WHITE) PLAINEND. PLAIN END PVC. PVC 1120. 1120 ASTMASTM D 2665. D 2665. WT. PER. PART NO. NOM. SIZE UPC # QTY. PER AVG. OD MIN. WALL 100 FT. 611942- SKID (IN.) (IN.) (LBS.). PVC 7100* 11 4 x10' 03945 2120' .140 PVC 7100* 11 4 x20' 03946 4240' .140 PVC 7112* 11 2 x10' 03947 1720' .145 PVC 7112* 11 2 x20' 03948 3440' .145 PVC 7200* 2 x10' 03949 990' .154 PVC 7200* 2 x20' 03950 1980' .154 PVC 4025 21 2 x20' 04205 1360' .203 PVC 7300* 3 x10' 03951 1040' .216 PVC 7300* 3 x20' 03952 920' .216 PVC 7400 4 x10' 03953 600' .237 PVC 7400 4 x20' 03954 1200'.

7 237 PVC 7500 5 x20' 04837 760' .258 PVC 7600 6 x10' 03955 280' .280 PVC 7600 6 x20' 03956 560' .280 PVC 7800 8 x20' 03958 360' .322 PVC 7910 10 x20' 03959 220' .365 PVC 7912 12 x20' 03961 120' .406 PVC 7914 14 x20' 04862 60' .437 PVC 7916 16 x20' 04918 60' .500 P. V. * Dual Marked ASTM D 1785 & ASTM D 2665. C. Triple Marked ASTM D 1785 & ASTM D 2665 & ASTM F 480. - D. Dual Marked ASTM D 1785 & ASTM F 480. W. NSF Listed. Meets All Requirements of V. ASTM D 1784, ASTM D 1785, and Testing with or use of compressed air or gas in PVC / ABS. ASTM D 2665. / CPVC pipe or fittings can result in explosive failures and P. cause severe injury or death. NEVER test with or transport/store I. compressed air or gas in PVC / ABS / CPVC P. pipe or fittings. NEVER test PVC / ABS / CPVC pipe or E. fittings with compressed air or gas, or air over water boosters. ONLY use PVC / ABS / CPVC pipe for water or approved chemicals. Refer to warnings in PPFA User Bulletin 4-80 and ASTM D 1785.

8 7. pipe Data PVC Sewer pipe PVC SDR 35 PSM pipe ASTM D 3034 & ASTM F 477. SDR-35 GASKETED - PS 46. PART NO. NOM. SIZE UPC # QTY. PER LAYING WT. PER AVG. OD MIN. WALL. 611942- SKID LENGTH 100 FT. (LBS.) (IN.) (IN.). /M 6004G S 4 x14' 11920 840 14'-0 .120. S/M 6004G 4 x20' 04012 1200 20'-0 .120. S/M 6006G 6 x14' 11921 392 14'-0 .180. S/M 6006G 6 x20' 04016 560 20'-0 .180. S/M 6008G 8 x14' 11922 140 14'-0 .240. Weight is approximate and is for shipping purposes only. SDR-35 SOLVENT WELD - PS 46. PART NO. NOM. SIZE UPC # QTY. PER LAYING WT. PER AVG. OD MIN. WALL. 611942- SKID LENGTH 100 FT. (LBS.) (IN.) (IN.). S/M 6004 4 x10' 04008 600 10'-0 .120. S/M 6004 4 x20' 04009 1200 20'-0 .120. S/M 6006 6 x10' 04013 280 10'-0 .180. S/M 6006 6 x20' 04014 560 20'-0 .180. Weight is approximate and is for shipping purposes only. Meets All Requirements of ASTM D 3034. SDR 35 Gaskets meet or exceed ASTM F 477. Gasketed joints meet ASTM D 3212. Testing with or use of compressed air or gas in PVC / ABS.

9 / CPVC pipe or fittings can result in explosive failures and cause severe injury or death. NEVER test with or transport/store compressed air or gas in PVC / ABS / CPVC. pipe or fittings. NEVER test PVC / ABS / CPVC pipe or fittings with compressed air or gas, or air NOT FOR PRESSURE over water boosters. ONLY use PVC / ABS / CPVC pipe for water Do not use PVC Sewer pipe for pressure applications. The or approved chemicals. use of sewer pipe in pressure applications may result in Refer to warnings in PPFA User Bulletin system failure and property damage. 4-80 and ASTM D 1785. 8. pipe Data PVC Sewer and Drain pipe PVC ASTM D 2729 pipe SOLVENT WELD BELLED END ASTM D 2729. PART NO. NOM. SIZE UPC # QTY. PER AVG. OD MIN. WALL BELL DEPTH WT. PER. 611942- SKID (IN.) (IN.) (IN.) 100 FT. (LBS.). VC 30030 3 x 10' 10903 810' P PVC 30040 4 x 10' 10905 500' Perforated PVC ASTM D 2729 pipe SOLVENT WELD BELLED END ASTM D 2729 P. PART NO. NOM. SIZE UPC # 611942- QTY. PER SKID AVG.

10 OD (IN.) MIN. WALL BELL DEPTH (IN.) (IN.) WT. PER. 100 FT. (LBS.). V. C. P VC 30030P 3 x 10' 11814 810' S. PVC 30040P 4 x 10' 11815 500' E. W. Perforated pipe is supplied with two rows of 1/2 diameter holes every five inches. E. Rows are parallel to the pipe axis and are 120 apart. R. Weight is approximate and is for shipping purposes only. P. I. pipe listed in this section meets or exceeds the requirements of ASTMD 2729. P. E. All products manufactured by Charlotte pipe and Foundry Company are proudly made in the Failure to follow safety precautions may result in misapplication or improper installation and testing which can cause severe personal injury and / or property damage. Primers and cements are extremely flammable and may be explosive. Do not store or use near heat or open flame, or death or serious injury may occur. Solvent fumes created during the joining process are heavier than air and may be trapped in newly installed piping systems. Ignition of the solvent vapors caused by spark or flame may result in injury or death from explosion or fire.