PLSPH1527 SkyAir MiddleStatic Complete low - Daikin Home

Specifications 50 60 71 100 125 140 125 140. PLSPH1527 . Model Indoor unit FBQ50 EVE FBQ60 EVE FBQ71 EVE FBQ100 EVE FBQ125 EVE FBQ140 EVE FBQ60 EVEx 2 FBQ71 EVEx 2. Name Outdoor unit RZR50 LVVM RZR60 LVVM RZR71 LVVM RZR100 LVVM RZR125 LVVM RZR140 LVVM RZR125 LVVM RZR140 LVVM. Power supply Indoor unit 1 Phase, 220 V, 60 Hz Outdoor unit 1 Phase, 220 230 V, 60 Hz Cooling capacity 1, 2 kW ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ). Rated (Min. - Max.). Power consumption 1 Cooling 1 kW COP W/W Fan (H/M/L) m3/min 18/15 23 32/27 36 18/15 23 Indoor unit cfm 635/530/441 812/688/565 1,130/953/794 1,271/1,077/883 635/530/441 812/688/565. External static pressure 3 Pa Rated 50 (50-150). Sound pressure level (H/M/L) 4 dB(A) 35/33/31 38/35/33 38 40 35/33/31 38/35/33.

Using a DC fan motor, the external static pressure can be controlled to within a range of 50 Pa to 150 Pa Higher lift is realized by utilising built-in DC

Tags:

  Daikin

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of PLSPH1527 SkyAir MiddleStatic Complete low - Daikin Home

1 Specifications 50 60 71 100 125 140 125 140. PLSPH1527 . Model Indoor unit FBQ50 EVE FBQ60 EVE FBQ71 EVE FBQ100 EVE FBQ125 EVE FBQ140 EVE FBQ60 EVEx 2 FBQ71 EVEx 2. Name Outdoor unit RZR50 LVVM RZR60 LVVM RZR71 LVVM RZR100 LVVM RZR125 LVVM RZR140 LVVM RZR125 LVVM RZR140 LVVM. Power supply Indoor unit 1 Phase, 220 V, 60 Hz Outdoor unit 1 Phase, 220 230 V, 60 Hz Cooling capacity 1, 2 kW ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ). Rated (Min. - Max.). Power consumption 1 Cooling 1 kW COP W/W Fan (H/M/L) m3/min 18/15 23 32/27 36 18/15 23 Indoor unit cfm 635/530/441 812/688/565 1,130/953/794 1,271/1,077/883 635/530/441 812/688/565. External static pressure 3 Pa Rated 50 (50-150). Sound pressure level (H/M/L) 4 dB(A) 35/33/31 38/35/33 38 40 35/33/31 38/35/33.

2 Dimensions (H X W X D) mm 245 X 1,000 X 800 245 X 1,400 X 800 245 X 1,000 X 800. Sound pressure Cooling dB(A) 48 49 50. Outdoor level 4 Nigth quiet mode dB(A) 44 45 46 45 46. unit Dimensions (H X W X D) mm 595 X 845 X 300 990 X 940 X 320 1170 X 900 X 320. 100 125 140 100 125 140. Model Indoor unit FBQ100 EVE FBQ125 EVE FBQ140 EVE FBQ100 EVE FBQ125 EVE FBQ140 EVE. Name Outdoor unit RZQ100 KCTLT RZQ125 KCTLT RZQ140 KCTLT RZQ100 LUYLT RZQ125 LUYLT RZQ140 LUYLT. Power supply Indoor unit 1 Phase, 220 V, 60 Hz Outdoor unit 3 Phase, 220 V, 60 Hz 3 Phase, 380 V, 60 Hz Cooling capacity 1,2 Cooling kW ( ) ( ) ( ) ( ) ( ) ( ). Rated (Min. - Max.). Power consumption Cooling 1 kW COP kW Indoor unit Fan (H/M/L) m3/min cfm 32/27 1,130/953/794.

3 36 1,271/1,077/883. 32/27 1,130/953/794. 36 1,271/1,077/883 FBQ50 EVE / FB60 EVE / FBQ71 EVE. External static pressure 3 Pa Rated 50 (50-150). Sound pressure level (H/M/L) 4. Dimensions (H X W X D). dB(A). mm 38 40 245 X 1,400 X 800. 38 40 FBQ100 EVE / FBQ125 EVE / FBQ140 EVE [60 Hz]. Sound pressure Cooling dB(A) 49 50. Outdoor level 4 Nigth quiet mode dB(A) 45. unit Dimensions (H X W X D) mm 1170 X 900 X 320. Note: 1 Rated cooling capacities are based on the following conditions: Indoor temp., 27 C DB, C WB; outdoor temp. 35 C DB , 24 CWB. Equiv. refrigeration piping, m (horizontal). 2. Capacities are net, including a deduction for cooling for indoor fan motor heat. 3. External static pressure is changeable in 11 stages by remote controller.

4 4. Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 5. iency(gravity method)50% or more. Options Indoor unit Kit nam e Name of optio n Remar k FBQ50 EVE FBQ60 EVE FBQ71 EVE FBQ100 EVE FBQ125 EVE FBQ140 EVE. High-e 1 65% KAFP632B80 KAFP632B160. 90% KAFP633B80 KAFP633B160. Filter chamber(for rear suction) 1 KDDFP63B80 KDDFP63B160. 1 KAFP631B80 KAFP631B160. Service pane l White KTBJ25K80W KTBJ25K160W. Fresh white KTBJ25K80F KTBJ25K160F. Brown KTBJ25K80T KTBJ25K160T. Air discharge adapto r KDAP25A71A KDAP25A140A. Shield plate for side plate KDBD63A160. Remote controlle r Wireless type Cooling only(RZR) BRC4C66.

5 Heat pump(RZQ) BRC4C65. Wired type 2 BRC1C61. Navigation Remote Controlle r Wired type 2 BRC1E62. Adaptor for wiring KRP1C64. Wiring adaptor for electrical appendices (2) KRP4AA51. Remote senso r KRCS01-4B. Mounting plate for adaptor PCB. 3,4,5 KRP4A98. Central remote controller 6 DCS302CA61. 6 DCS301BA61. Schedule timer 6 DST301BA61. intelligent Touch Controller 6 DCS601C51. Note: 1If installing high e 4. 2 5. Wiring for wired remote controller to be procured locally. Only one mounting plate can be installed for each indoor unit. 3 6. Mounting plate is necessary for each adaptor marked . The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.

6 Outdoor unit Kit name RZR50 LVVM RZR125 LVVM RZQ100 KCTLT RZQ100 LUYLT. Name of optio n RZR60 LVVM RZR100 LVVM RZQ125 KCTLT RZQ125 LUYLT. RZR71 LVVM RZR140 LVVM RZQ140 KCTLT RZQ140 LUYLT. Central drain plug KKP014A4 KKPJ5G280 KKPJ5F180. Fixture for preventing overturning ---------- KKTP5B112 KPT-60B160. ---------- K-KYZP15C. Demand adaptor ---------- KRP58M51. Refrigerant branch piping kit For twin multi ---------- KHRP58P216T ---------- 2nd Floor Hanston Square, 17 San Miguel Ave, Ortigas Center, Pasig City, 1605. Tel. No (02) 942 - 6800 / 942 - 6792 Fax: (02) 942 - 6793. notice. c All rights reserved 06/15 SS. Thinner design Design and installation Using a DC fan motor, the external static Easy maintenance pressure can be controlled to within a range of allows greater flexibility 50 Pa to 150 Pa Position of drain pan inspection opening has been modi ed for easier inspection installation flexibility With a height of only 245 mm, installation is Adjustable external static pressure work possible even in buildings with narrow ceiling spaces Drain pan maintenance check window 50 Pa 150 Pa This makes it possible to inspect for drain pan dirt Set to low static Set to high static pressure for the use of tools.

7 245 mm pressure when ducts advanced needs such as when are short. using dampers and long ducts. such as duct length. Inspection One of the industry's most compact opening for drain pan bodies in the mid-static pressure range. Ai rate auto adjustment function Drain pan maintenance check window Indoor unit 71E 100/125/140E. run. Height (mm) 245 It is automatically adjusted to approximately 10% of the Easy maintenance because the drain pan Width (mm) 1,000 1,400. can be removed Depth (mm) 800. Interlock control by outside system Higher lift is realized by utilising built-in DC Enables control by hotel key card system acting as master drain pump with standard accessory ON/OFF for room electricity.

8 Enables central control of room ventilation and lighting by High efficiency third-party building management system. DC fan motor and DC drain pump are utilised to improve energy e ciency Middle & High static 850 mm pressure type (FBQ-D series). 700 mm Interlock Simultaneous air conditioning of two rooms Bottom suction is available and ventilation grille (ventilation opening). When air conditioning two rooms simultaneously, unit joist the air discharged into each room must be circulated back to the air conditioner. To achieve DIII-NET communication standard this, a ventilation duct should be installed for each Air suction room or one of the indicated ventilation grilles Easier communication and connection with the centralised ceiling control system.

9 Should be installed on the partitioning wall or under the door between the rooms. Wiring and servicing can be done from the underside of the unit (an option part required). Rear suction Bottom suction Comfort Ventilates air through Partitioning wall Sield plate for side plate(option). Switchable fan speed:High/Middle/Low and Auto the partitioning wall. (See below). ( Auto is applicable when BRC1E62 is used.). Door-installed Wall-installed ventilation grille ventilation grille Under-door cutout Clean Control box Switch bottom plate with cover Bottom Air suction plate Make the control box Bottom plate face inward. Silver ion anti-bacterial drain pan Ventilation grille Ventilation grille Under-door cutout A built-in antibacterial treatment that uses silver ion in the drain pan prevents the growth of slime, bacteria, and mould Note: The under-door cutout method should be used only when that cause smells and clogging.

10 Control box cover Control box faces outward. Control box faces inward.