Transcription of PM 21 - 2008 English - Chapter 4
1 Siemens pm 21 20084 Synchronous motors4/2 Type overview and rated data4/4 Technical definitions4/10 Encoder systems4/121FT6 motors4/381FT7 Compact motors4/521FK7 Compact and1FK7 High Dynamic motors4/60 Selection guides4/60 Built-in holding brakes4/61 Types/mounting position, degree ofprotection4/62 Gearboxes4/62 Series SP+ planetary gearboxfor 1FT6 motors4/67 Series SP+ planetary gearboxfor 1FT7 motors4/72 Series SP+ planetary gearboxfor 1FK7 motors4/78 Series LP+ planetary gearboxfor 1FK7 motors4/80 Geared motors4/801FK7-DYA compact gearedmotors4/841FK7 geared servomotors4/1181FS6 motors.
2 Explosion-protected4/1221FW3 torque motors4/136 Dimension drawings4/1361FT6 motors4/1491FT7 Compact motors4/1511FK7 Compact motors4/1531FK7 High Dynamic motors4/1541FT6 motors withSP+ planetary gearbox4/1591FK7 motorswith SP+ planetary gearbox4/1641FK7 motorswith LP+ planetary gearbox4/1671FK7-DYA motorswith planetary gearbox4/1681FS6 motors4/1691FW3 torque motorsPart12 CAD CREATORD imension drawing and2D/3D CAD motors Siemens AG 2008 Synchronous motorsOverviewType overview and rated data4/2 Siemens pm 21 20084 MotortypeDesignation/Principle of operationDegree ofprotectionCooling method1FT6 Servo motor High PerformancePermanent-magnetsynchronous motorIP64(optionalIP65, IP67,IP68)Natural coolingForced ventilationWater cooling1FT7 CompactServo motor High PerformancePermanent-magnetsynchronous motorIP64(optionalIP65, IP67)Natural cooling1FK7 CompactCompact servo motorPermanent-magnetsynchronous motorIP64(optionalIP65)
3 Natural cooling1FK7 HighDynamicHigh Dynamic servo motorwith extremely lowmoment of inertiaIP64(optionalIP65)Natural cooling1FK7-DYAC ompact geared motorIP64 Natural cooling1FK7 Servo geared motorIP65 Natural cooling1FS6 Servo motor explosion-protectedPermanent-magnetsynch ronous motor in typeof protectionEEx de II C T3IP64(optionalIP65)Natural cooling1FW3 Torque motorLiquid cooled,permanent-magnetsynchronous motorIP54 Water cooling1FU8 SIEMOSYN motorPermanent-magnetsynchronous motorIP54(2-pole)IP55(4-/6-pole)Natural cooling Siemens AG 2008 Synchronous motorsOverviewType overview and rated data4/3 SiemensPM21 20084 Shaft heightOutput rangein kW/HPTorque rangein Nm/lbf-inSelection.
4 13280 .. 16063 .. 88( .. 779 lbf-in)17 .. 540(151 .. 4779 lbf-in)10 .. 690(89 .. 6107 lbf-in)4/16 .. 4/274/28 .. 4/334/34 .. 4/3736 .. 61( .. 540 lbf-in)4/40 .. 4/5120 .. 37( .. 327 lbf-in)4/54 .. 4/554/58 .. 4/5936 .. 12(8 .. 106 lbf-in)4/56 .. 4/5936 .. 70( .. 619 lbf-in)4/82 .. 4/8336 .. 1740( .. 1283 lbf-ft)4/86 .. 4/11271 .. 68(17 .. 602 lbf-in)4/120 .. 4/121150200280100 .. 7000( .. 5163 lbf-ft)4/124 .. 4/13571 .. ( .. 528 lbf-in)See Catalog DA ( ) (11) ( ) ( ) ( ) ( ) ( ) ( ) ( ) (21) ( ) 89 (119) ( )118 (158) ( ) ( ) ( )177 (237) ( ) (31) ( ) (14)
5 Siemens AG 2008AC motorsOverviewTechnical definitions4/4 Siemens pm 21 20084 Regulations, standards and specificationsThe motors comply with the appropriate standards and regula-tions, see table a result of the fact that in many countries the national regula-tions have been completely harmonized with the internationalIEC 60034-1 recommendation, there are no longer any differ-ences with respect to coolant temperatures, temperatureclasses and temperature rise motors listed below are UL-approved by "Underwriters Lab-oratories Inc.
6 " and also comply with Canadian URc standards:1FK7, 1FT6, 1FT7, 1FW3, 1PH7 (without brake), 1PL6, EX motors are CSA - approved. The most common degrees of protection for AC motors in accordance with IEC 60034-5A suitable degree of protection must be selected to protect themachine against the following hazards depending on the rele-vant operating and environmental conditions: Ingress of water, dust and solid foreign objects; contact with or approach to rotating parts inside a motor and contact with or approach to live of protection of electric motors are specified by a comprises of 2 letters, 2 digits and, if required, an (International Protection)
7 Code letter designating the degree of protection against contactand the ingress of solid foreign objects and water0to61st digit designating the degree of touch protection and protec-tion against ingress of solid foreign objects0to82nd digit designating the degree of protection against ingress ofwater (no oil protection)W, SandMAdditional code letters for special degrees of protectionTitleDIN/VDEDIN IECG eneral specifications for rotating electrical machinesDIN VDE 0530 Part 1 DIN IEC 60034-1 Terminal designations and direction of rotation for electrical machinesDIN VDE 0530 Part 8 DIN IEC 60034-8 Types of rotating electrical machinesDIN VDE 0530 Part 7 DIN IEC 60034-7 Cooling methods of rotating electrical machinesDIN VDE 0530 Part 6 DIN IEC 60034-6 Degrees of protection of rotating electrical machinesDIN VDE 0530 Part 5 DIN IEC
8 60034-5 Vibration severity of rotating electrical machinesDIN VDE 0530 Part 14 DIN IEC 60034-14 Noise limit values for rotating electrical machinesDIN VDE 0530 Part 9 DIN IEC 60034-9 Cylindrical shaft extensions for electrical machinesDIN 748 Part 3 DIN IEC 60072 Most motors are supplied with the following degrees of protection:MotorDegreeof pro-tection1st digitTouchprotectionProtectionagainstfor eignobjects2nd digitProtection againstwaterInter-nallycooledIP23 Protectionagainst fingercontactProtectionagainstmedium-siz ed, solidforeignabove 12 mm( in)
9 Protection againstspray water up to 60 from the verticalSurface-cooledIP54 Completeprotectionagainstaccidentalconta ctProtectionagainstharmful dustdepositsSplash water fromany directionIP55 Jet-water from anydirectionIP64 Completeprotectionagainstaccidentalconta ctProtectionagainst dustingressSplash water fromany directionIP651)Jet-water from anydirectionIP671)Motor under speci-fied pressure andtime conditionsunder waterIP681)Motor can be com-pletely submersed inwater under condi-tions which themanufacturer mustspecify1)DIN VDE 0530 Part 5 or EN 60034 Part 5 specifies that there areonly 5 degrees of protection for the first digit code and 8 degrees ofprotection for the second digit code in relation to rotating electricalmachinery.
10 However, IP6 is included in DIN 40050 which generallyapplies to electrical equipment. Siemens AG 2008AC motorsOverviewTechnical definitions4/5 Siemens pm 21 20084 Radial eccentricity tolerance, shaft and flange accuracy (concentricity and axial eccentricity) in accordance with IEC 60072 Radial eccentricity tolerance of shaft in relation to housingaxis(refers to cylindrical shaft extensions)Concentricity and axial eccentricity tolerance of theflange surface to the shaft axis(referred to the centeringdiameter of the mounting flange)