Power Supplies3 Contact Technical Services at (800) 377-4384 with any questions. Visit our website at 117 The SDN-C din rail power supplies are the next generation of the popular SDN series. These models combine high efficiency and compact size with new visual diagnostic LEDs to offer the most performance available from SolaHD. Essential industrial features such as Sag Immunity, Power Factor Correction, and universal voltage input have been retained in this series. Wide temperature operating range and parallel operation capability make the new SDN-C units suitable to a variety of industrial Industrial Machine Control and Process Control Conveying Equipment Material Handling Vending Machines Packaging Equipment and Amusement Park Equipment Semiconductor Fabrication Equipment DeviceNetTMFeatures Compact packaging to save space on the din rail Visual diagnostic LEDs for input and output status at a glance High MTBF means high reliability and long life Higher efficiency saves energy and lowers amount of heat generated i

Po 3 Contact Technical Services (800) 377-4384. V ... 117 The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high efficiency and compact size with new visual diagnostic

Tags:

  Rail, Din rail

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Po - Sola/Hevi-Duty Products

1 Power Supplies3 Contact Technical Services at (800) 377-4384 with any questions. Visit our website at 117 The SDN-C din rail power supplies are the next generation of the popular SDN series. These models combine high efficiency and compact size with new visual diagnostic LEDs to offer the most performance available from SolaHD. Essential industrial features such as Sag Immunity, Power Factor Correction, and universal voltage input have been retained in this series. Wide temperature operating range and parallel operation capability make the new SDN-C units suitable to a variety of industrial Industrial Machine Control and Process Control Conveying Equipment Material Handling Vending Machines Packaging Equipment and Amusement Park Equipment Semiconductor Fabrication Equipment DeviceNetTMFeatures Compact packaging to save space on the din rail Visual diagnostic LEDs for input and output status at a glance High MTBF means high reliability and long life Higher efficiency saves energy and lowers amount of heat generated in panel PowerBoostTM overload capability to start high inrush loads Accepts Universal voltage 85-264 Vac.

2 50/60 Hz input Active Power Factor Correction Patented din rail mounting clip User Adjustable output voltage accessible via front face Parallel capability standard Large, rugged, accessible screw terminals Industrial grade design - -25oC to 60oC operation without derating Fully tested and burned-in at factory Highly efficient switching technology Five year limited warrantyCertifications and Compliances *All Models UL 508 ListedIND. CONT. Listed, Ind. Control Equipment, E61379- UL 508, CSA No. Compact din rail Series UL 60950 E137632 234-M90UL Recognized Component, ITE, E137632 - UL 60950-1/CSA No. 60950-1, 2nd Edition EMC andLow Volt. Directive - Low Voltage Directive- IEC/EN60950-1, 2nd Edition Sag Immunity: SEMI F47 RoHS CompliantModels SDN 20-24-100C, SDN 20-24-480CC, SDN 40-24-480C UL 60950 E137632 234-M90UL Recognized Component, Haz.

3 Loc., E234790- ISA , CSA No. 213- Class I, Division 2, Groups A, B, C, DModels SDN 5-24-100C, SDN 10-24-100C, SDN 5-24-480C, SDN 10-24-480C UL 60950 E137632 234-M90UL Recognized Component, Haz. Loc., E234790 - UL 60079-15/CSA E60079-15 - Class I, Zone 2, AEx nC IIC, Ex nC IIC ATEX Directive - EN60079-0, EN60079-15 - II 3 G, Ex nC IIC GcRelated Products SDN-P series SDPTM series SCP series SDU UPSA ccessories Chassis Mount Bracket (SDN-PMBRK2)UL 508 ListedIND. CONT. 60950 E137632 234-M90E61379E137632E234790* Refer to user manual for installation requirements when used in hazardous andLow Volt. DirectivePower Supplies3 Contact Technical Services at (800) 377-4384 with any questions.

4 Visit our website at 118 Rugged metal housingThe SolaHD DifferenceLarge, IP20-rated, screw terminals for #10 AWG/6 mm2, for quick, easy installationMultiple output connections for ease of wiring multiple devicesSingle or parallel use selectable by userClearly labeled front panelMultiple certifications for versatility in applicationsAutomatically adjusts for global Input voltages. No manual intervention width saves panel spaceNo internal fan, no extra cooling required in any power levelAdjustable output voltageDC OK RelayVisual diagnostic LEDs show input and output status (see table below)LED Light Status ConditionsNormalAC Power LossAC Input LowNo DCHigh LoadOverloadHotToo HotInputGreen-YellowGreenGreenGreenGreen GreenOutputGreen-Green-YellowYellowGreen -Alarm---RedYellowRedYellowYellowPower Supplies3 Contact Technical Services at (800) 377-4384 with any questions.

5 Visit our website at 119 DescriptionCatalog NumberSDN 5-24-100 CSDN 10-24-100 CSDN 20-24-100 CInputNominal Voltage115/230 Vac-AC Range85 - 264 Vac-DC Range 190 - 375 Vdc-Frequency43 - 67 HzNominal Current - - A6 A / 3 A-Inrush current < 15 ATyp.< 30 A< 40 AEfficiency (Losses 3)> 90% typ. (12 W)> 90% typ. (24 W)> 92% (38 W)Power Factor CorrectionActive power factor correction to better than Voltage 24 V ( ~ Vdc Adj.)-Tolerance< 2 % overall (combination Line, load, time and temperature related changes)Initial Voltage V 1%-Ripple 4< 50 mVpp<100 mVppPARDPARD (Periodic and Random Deviation) = 100 mV peak-peak maxOvervoltage Protection> but < 33 Vdc, auto recoveryPower Back Immunity< 35 VNominal Current5 A (120 W)10 A (240 W) 20 A (480 W)-Peak Current Nominal Current for 2 seconds minimum while holding voltage > 20 Vdc-Short Circuit x Nominal Current at near zero volts at short circuit condition-Current LimitPowerBoost Parallel OperationSwitch selectable single unit or parallel unit operation.

6 Units will not be damaged by parallel operation (regardless of switch position setting).Holdup Time>20 ms (Full load, 100 Vac Input @ Tamb=+25 C) to 95% output voltageVoltage Fall Time<150 mS from 95% to 10% rated voltage @ full load (Tamb=+25 C)Line and Load Regulation< : -EmissionsEN61000-6-2:2001, EN61000-6-3:2001, Class B EN55011, EN55022 Radiated and Conducted including Annex. A, EN61000-3-2 -ImmunityEN61000-6-1:2001, EN61000-6-2:2001, EN61000-4-2 Level 4, EN61000-4-3 Level 3, EN61000-4-6 Level 3, EN61000-4-4 Level 4 input and level 3 output. EN61000-4-5 Isolation class 4, EN61000-4-11, IEC 61000-4-34 voltage dip immunity standardTemperature 6 Storage: -40oC to + 85oC, Operation -25oC to +60oC full power, with linear derating to half power from 60 to 70oC (Convection cooling, no forced air required).

7 Operation up to 50% load permissible with sideways or front side up mounting 7 > 550,000 hrs > 450,000 hrsWarranty5 Year Limited WarrantyGeneral Protection/SafetyProtected against continuous short -circuit, continuous overload, continuous open Class 1 (IEC536), degree of protection IP20 (IEC60529) Safe low voltage: SELV (acc. IEC60950-1)Status IndicatorsVisual: 3 status LEDs (Input, Output, Alarm)Relay: contact rated 200ma/50 VdcInstallationFusing -InputInternally fused -OutputOutputs are capable of providing high currents for short periods of time for inductive load startup or switching. Fusing may be required for wire/loads if 2x Nominal O/P current rating cannot be tolerated. Continuous current overload allows for reliable fuse tripping.

8 MountingSimple snap-on to DIN TS35 or TS35/15 rail system. ConnectionsInput: Screw terminals, connector size range: 16-10 AWG ( mm2) for solid : Two terminals per output, connector size range: 16-10 AWG ( mm2) for solid enclosed metal housing with fine ventilation grid to keep out small Space 15 mm in front, 25 ~ 40 mm above and below, 10 mm left and x W x D inches (mm) ( ) ( ) x x ( x x )Weight lbs (kg) ( ) ( ) ( )SDN-C Specifications (Single Phase)1. Not UL listed for DC Input current ratings are conservatively specified with low input, worst case efficiency and power factor. 3. Losses are heat dissipation in watts at full load, nominal input Ripple/noise is stated as typical values when measured with a 20 MHz, bandwidth scope and 50 Ohm Peak current is calculated at 24 Volt Contact tech support for operation at -25oC.

9 7. Demonstrated through extended life Supplies3 Contact Technical Services at (800) 377-4384 with any questions. Visit our website at 120 SDN-C Specifications (Three Phase)DescriptionCatalog NumberSDN 5-24-480 CSDN 10-24-480 CSDN 20-24-480 CCSDN 40-24-480C InputNominal Voltage380 - 480 VacTwo - phase inputYes 1 -AC Range 2320 - 540 Vac -DC Range450 - 760 Vdc450 - 760 Vdc450 - 760 Vdc 9N/A -Frequency50/60 HzNominal Current 33 x or 2 x A3 x or 2 x A3 x or 2 x A3 x A -Inrush current <25 ANegligibleNegligibleEfficiency (Losses 4)> 85% (18 W) ( W)93% (42 W)94% (78 W)Power Factor CorrectionPower factor correction to meet EN61000-3-2 Class AActive Power Factor Correction OutputTurn on timeTyp.

10 1sVoltage Rise Timeca. 5-20 ms<100 ms full resistive load (Tamb =+25 C )Power Back Immunity<35 VOvervoltage Protection> but <33 Vdc auto recoveryNominal Voltage24 V (24 - 28 Vdc Adjustable)Voltage Regulation< 2 % overallInitial Voltage V 1% -Ripple 5<100 mVppPARDPARD = 100 mV peak-peak maxPARD = 200 mV peak-peak maxNominal Current5 A (120 W) 10 A (240 W) 20 A (480 W) (constant power, not constant current)40 A (960 W) -Peak Current 66A, 2 Nominal Current <2sec 12A, 2 Nominal Current < Nominal Current for 4 sec minimum while holding voltage > 20 Vdc -Current LimitPowerBoost Deratingtyp. 6 W/oCtyp. 12 W/oCtyp. 24 W/oCtyp. 48 W/oCHoldup Time>20 ms>15 msVoltage Fall Time<150 ms from 95% to 10% rated voltage @ full load (Tamb=+25 C)<50 ms from 95% to 10% rated voltage @ full load (Tamb=+25 C)Parallel Operation 7 Single or Parallel operation selectable via front switch.