POLYCOOL AC&R Controller RWR470.10 Basic …

POLYCOOL AC&R Controller documentation for gsww1/28 Siemens Building TechnologiesSIEMENS ControllerHEAT PUMP controllerHVAC of Contents1 Range of Equipment Product Key Important Operation ..3 LCD Display ..3 Menu Access Wiring Examples ..7 Connection Wiring with Power Wiring with Digital Wiring with Passive Temperature Wiring with Digital General Device Modes of Accessing the Selection of System Viewing Changing Setpoints (for end users)..125 Fast Configuration via Downloading Application and Parameters from PolyStick ..136 Customizing Application by Adjusting Parameter Values ..13 Accessing the Parameter Menu ..13 Adjusting Parameter Warning Codes for Viewing Warning Alarm Auto Reset Alarms ..16 Manual Reset Alarms ..16 Viewing Alarm Acknowledging and Resetting Manual Reset Alarms.

POLYCOOL AC&R Controller RWR470.10 Basic Documentation for gsww 1/28 Siemens Building Technologies SIEMENS Controller HEAT PUMP controller HVAC Products 27.11.2006

Tags:

  Controller, Basics, Documentation, Ac amp r controller rwr470, Rwr470, 10 basic, 10 basic documentation for

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of POLYCOOL AC&R Controller RWR470.10 Basic …

1 POLYCOOL AC&R Controller documentation for gsww1/28 Siemens Building TechnologiesSIEMENS ControllerHEAT PUMP controllerHVAC of Contents1 Range of Equipment Product Key Important Operation ..3 LCD Display ..3 Menu Access Wiring Examples ..7 Connection Wiring with Power Wiring with Digital Wiring with Passive Temperature Wiring with Digital General Device Modes of Accessing the Selection of System Viewing Changing Setpoints (for end users)..125 Fast Configuration via Downloading Application and Parameters from PolyStick ..136 Customizing Application by Adjusting Parameter Values ..13 Accessing the Parameter Menu ..13 Adjusting Parameter Warning Codes for Viewing Warning Alarm Auto Reset Alarms ..16 Manual Reset Alarms ..16 Viewing Alarm Acknowledging and Resetting Manual Reset Alarms.

2 172/28 Siemens Building TechnologiesSIEMENS ControllerHEAT PUMP controllerHVAC Main Control Compressor Capacity Temperature compensation at Boiler19 3 way valve/ daily hot water pump control ..19 Alarm 19 Control process ..19 TURN ON process at Protection Paramter Compressor Condenser Evaporator Special User User Alarm Building TechnologiesSIEMENS ControllerHEAT PUMP controllerHVAC of UnitsDeviceNameTypeDatasheet CombinationDeviceTypeDatasheet with a sensing element LG Ni 1000 , Silicon cable 200cm, with -50 +80 C measurement with a sensing element NTC10 k , PVC cable 600cm, with -25 +80 C measurement rangeQ1843 Pressure sensorQBE9101-P10U, +9 bar / QBE9101-P30U, +29bar / QBE9101-P60U, +59 bar, with mA output signalQ1908 QBE2001-P10U, +9 bar / QBE2001-P25U, +24 bar / QBE2001-P60U, +59 bar.

3 With DC V output signalN1907 QBE620-P40U, with output signalN1904 Texas Instruments 2CP5-47/48 operates on 5 VDC supply voltage with + + bar measurement range and DC V output signal Product DocumentationIn addition to this Basic documentation , the pieces of product documentation listed below provide detailed information on the safe and proper use and operation in building services of documentOrdering FeaturesIts main features are as follows: Non-programmable stand-alone Controller , or networked via the communication of PCLBUS1/28 Siemens Building TechnologiesSIEMENS ControllerHEAT PUMP controllerHVAC Strict user privilege control Multiple applications can be configured by setting parameters Control of inlet/outlet water/water temperature Fast application (with parameters) uploading and downloading via PolyStick Complete alarm and warning management User-friendly icon HMI, LCD display and light blue backlightImportant NotesThis symbol draws your attention to special safety notes and warnings.

4 If such notes are not observed, personal injury and / or considerable damage to property can Controller may only be used for the control and supervision of heating, ventilation, air conditioning and chiller for flawless and safe operation of Controller are proper transport, installation, commissioning, and correct , switches, wiring and earthing must be in compliance with local safety regulations for electrical for use of commission of Controller must be undertaken by qualified staff who have been appropriately trained by Siemens Building Controller may only be operated by staffs who have been instructed by Siemens Building Technologies or their delegates and whose attention has been drawn to potential wiring the system, the AC 240V section must be strictly segregated from the AC 24V safety extra low-voltage (SELV) section in order to ensure protection against electric shock hazard!

5 !For storage and transport, the limit values given in the relevant Datasheet must be always be observed. System sections accommodated in the control panel should be freed from dust and dirt whenever normal service visits are system faults occur and you are not authorized to make diagnostics and to rectify faults, call your service staff of Siemens Building authorized staffs are permitted to make diagnostics, to rectify faults and to restart the plant. This also applies to work carried out within the control panel ( safety checks or changing fuses).The products contain electrical and electronic components and may not be disposed of as household and currently legislation must be complied with!2/28 Siemens Building TechnologiesSIEMENS ControllerHEAT PUMP controllerHVAC of UseElectrical InstallationCommissioningOperationWiring Storage and TransportMaintenanceFaultsDisposal2 Operation LCD Display Operation of is fully driven by buttons and buttonsSystem +24V+5VQ64Q54Q44Q34Q24Q14Q13D1MD2D3MD4D5 MGG0RS485 GND+-RJ45 LED 1 Display 2(Value)Display 1(Parameter)

6 MenusLED 2 DevicesButtonNameUse<Esc> In Menu /parameter setting mode, press it to return to the previous menu level, or to reject the value entered<Enter> Press down it for more than 2 seconds and release it to enter the Menu modeIn Menu/parameter setting mode, press it to confirm the selected menu level, or the value enteredPress it to acknowledge/reset warnings and alarms+<Plus> Press it for 2 seconds to activate the System Mode in stop modeOr, press it to select the menu level, or to increase the value in Menu/parameter setting mode<Minus> Press it to select the menu level, or to decrease the value in Menu/parameter setting modeIconMeaningFunctionQuery/viewActual values of all temperature!WarningExistence of warning, and the latest 10 warningsAlarm Existence of alarm and the latest 20 alarmsParameters Set parameters and values (see also Menu Tree) The unit of compressor and pump running time is 100 for how to access the Query/Warning/Alarm/Parameter menus above, see also <Chapter Accessing the Menus>Parameters listed under the menu vary with the password privileged user.

7 3/28 Siemens Building TechnologiesSIEMENS ControllerHEAT PUMP controllerHVAC buttonsLegend for menusNoteNotesBefore accessing the Parameter menu, select the user group ( NO EU or ID ) first and input the corresponding password that is required for the service men and factory also <Chapter Accessing the Parameter Menu>On the right lower side, nine icons are used to indicate system modes and on/OffHot water (The icon is dispalyed in house)Coolingcompressor HeatingCommunicationHouse (All devices within this icon are called indoor devices.)When the device is activated, the corresponding icon will be the right middle area, the icons are used to indicate the work status of the and IndicationCompressor On solid: RunningBlinking : Alarms related to compressorFlow switchBlinking: flow switch alarm Indoor pump On solid: runningBlinking: alarms detectedOutdoor pumpFor any warning/alarm detected, the corresponding device icon and the !

8 / icon will blink continuously until the alarm is acknowledged or reset4/28 Siemens Building TechnologiesSIEMENS ControllerHEAT PUMP controllerHVAC for system Mode and statusNotesLegend for devicesNotesMenu TreeMenusCM01 CMCM02CM03CN01 CNCN02CN03CM13CM14CM15EV01 EVEV02EV03EV04SF01SF02SF03 SFSF11SF12SF13UI01UI02UI03UI04UI05UI06 UIAL01AL02AL03 ALAL11AL12AL13CN26CN27CN28!ST01 STST02ST03ST04ST05ST06ST07ST08ST11ST12ST 13By default, end users can access all parameters in ST settingsSTSetpoints CNCondenser settingsUIUser interfaceEVEvaporator settingsALAlarm settingsSFSpecial functionsAccess RightsThree groups of users with different privilege levels are described LevelUserMain ActivitiesSpecialAllIDFactory User Password required Configure and commission applications by setting/adjusting parameter valuesEUService Men Password required Configure and commission applications by setting/adjusting parameter valuesNOEnd User No password is required Adjust limited values of parameters (by default , can only adjust values of parameters in the ST group)

9 View information and status Acknowledge warnings and alarms Heating /Cooling changeover5/28 Siemens Building TechnologiesSIEMENS ControllerHEAT PUMP controllerHVAC for parameter groups3 Wiring Examples Connection TerminalsPolyCool descriptions of the inputs and the outputs are summarized as AssigmentsTerminal AssignmentsGPower supply AC/DC 24 VQ13 Supply 1 (AC 24 V ..230 V)G0 Power supply groundQ14 Compressor1 PESaftey groundQ24 Compressor2Q34 Indoor water pumpX1 Inlet water temperature of indoor sideQ44 Outdoor water pumpX2 Outlet water temperature of indoor sideQ544-way valveX3 Atmospheric temperature of outdoorQ64 BoilerX4 Hot water temperatureX5 Outlet water temperature of outdoor side Q23 Supply 2 (AC 24 V ..230 V)X6 Inlet water temperature of outdoor side orevaporating temperatureQ74 Hot water pumpGNDC ommon reference point for analog inputQ84 Alarm+5 VDC 5 V power output for active sensorY1 Analog ouput 1, V+24 VDC 24 V power output for active sensorGNDC ommon reference pointY2 Analog output 2.

10 VD1 Water flow switchD2 Low pressure switchA+A+ connector for RS485 D3high pressure switchB-B- connector for RS485D4 Air condition switchGNDO ptional for RS485 communicationD5 Hot water switchRJ45 Service interface for parameters uploading and downloadingMCommon reference point for digital input6/28 Siemens Building TechnologiesSIEMENS ControllerHEAT PUMP controllerHVAC with Power is supplied with 24 VAC 20 % or 24 VDC 10 % via plug-in terminals G and G0 L1N220/230 VAC 50/60 Hz24 VACSPSNGG0 PEWiring with Digital offers five digital inputs for connecting safety devices, alarms, device status, and remote switches. These digital inputs are voltage following figure represents an example of wiring the digital input D2D3MD4D5MD1 MGG0 PEDigital InputsWiring with Passive Temperature SensorsBefore wiring with passive sensor, pay attention to the following: Terminals can be wired with NTC 10K , NTC 10 k temperature sensorX67/28 Siemens Building TechnologiesSIEMENS ControllerHEAT PUMP controllerHVAC with Digital OutputsThe following is a wiring example with relay 1NE-heaterE-heater with 220/230 VAC supply voltageQ13Q14Q24Q34Q44Q54Q64 Fuse8/28 Siemens Building TechnologiesSIEMENS ControllerHEAT PUMP controllerHVAC Device SettingsModes of OperationThe current Controller consists of three kinds of operation modes.


Related search queries