Portableflue gasmonitoringLANCOM IIIC ombustion & Environmental MonitoringCOLowCOHighO2 NONO2 NOxSO2H2 SCxHyCO2 COLowCOHighO2 NONO2 NOxSO2H2 SCxHyCO2 LANCOM IIIthe world s most versatile portable flue gas analyzerMonitoring of up 17 measurement parameters - one instrument to meet all requirementsUp to 9 simultaneous gas measurements - user selectableWeighs only 6kg (13lbs) - easily carried around plantRobust, industrial design - for daily use in the harshest plant environmentsIntegral printer - instant record of measurement readingsWake and Sleep, semi-continuous operation mode - for periodic unattended operationRange of user selectable options - ideally matched to application requirementsData acquisition & analysis software - capture, manipulate, and report data on your PCSimple field upgrade - add features and options as and when requiredMeets US EPA CTM 034 reference method - report generation to recognized standardsFeatures & BenefitsThe new Lancom III is now firmlyestablished at the forefront of portableflue gas analyzer excess of two thousand Lancomanalyzers are in use today, in a widerange of applications - all subjected tovery different measurement compCOHighO2 Combustion & Environmental calculationsCombustion efficiencyLossExcess AirCO2 (where no sensor fitted)

Combustion & Environmental calculations Combustion efficiency Loss Excess Air CO 2 (where no sensor fitted) Oxygen normalization Total NOx Wet or dry basis Automatic conversions - ppm, mg/m3, lb/mmBtu, ng/J Measurement Specifications

Tags:

  Portable, Specification, Monitoring, Fuel, Portable flue gas monitoring

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of portable flue gas monitoring - L-IR Korea

1 Portableflue gasmonitoringLANCOM IIIC ombustion & Environmental MonitoringCOLowCOHighO2 NONO2 NOxSO2H2 SCxHyCO2 COLowCOHighO2 NONO2 NOxSO2H2 SCxHyCO2 LANCOM IIIthe world s most versatile portable flue gas analyzerMonitoring of up 17 measurement parameters - one instrument to meet all requirementsUp to 9 simultaneous gas measurements - user selectableWeighs only 6kg (13lbs) - easily carried around plantRobust, industrial design - for daily use in the harshest plant environmentsIntegral printer - instant record of measurement readingsWake and Sleep, semi-continuous operation mode - for periodic unattended operationRange of user selectable options - ideally matched to application requirementsData acquisition & analysis software - capture, manipulate, and report data on your PCSimple field upgrade - add features and options as and when requiredMeets US EPA CTM 034 reference method - report generation to recognized standardsFeatures & BenefitsThe new Lancom III is now firmlyestablished at the forefront of portableflue gas analyzer excess of two thousand Lancomanalyzers are in use today, in a widerange of applications - all subjected tovery different measurement compCOHighO2 Combustion & Environmental calculationsCombustion efficiencyLossExcess AirCO2 (where no sensor fitted)

2 Oxygen normalizationTotal NOxWet or dry basisAutomatic conversions - ppm, mg/m3, lb/mmBtu, ng/JMeasurement SpecificationsSensorStandard RangeMax. Range# AccuracyResolutionOxygen, O2 0 to % to % Vol. 1 % % Monoxide, CO (low)0 to 2 000 ppm0 to 10 000 ppm 2 %* 1 ppmCO (H2) compensated0 to 2 000 ppm0 to 4 000 ppm 2 %* 1 ppmCarbon Monoxide, CO (high)0 to 4 %0 to 10 % 2 %* 1 ppmSulphur Dioxide, SO20 to 2 000 ppm0 to 5 000 ppm 2 %* 1 ppmNitric Oxide, NO0 to 1 000 ppm0 to 5 000 ppm 2 %* 1 ppmNitrogen Dioxide, NO20 to 100 ppm0 to 1000 ppm 2 %* 1 ppmHydrogen Sulphide, H2S0 to 200 ppm0 to 1 000 ppm 2 %* 1 ppmCarbon Dioxide, CO2 **0 to % % Vol % to % Vol. (Application dependent)Flue Gas/Ambient TemperatureMeasuredDraft 51 cm / 20 " Water Gauge **Flow (velocity)1 to 50 m/sNote: Special ranges are available*Calibration per CTM034 or LAND factory procedure**True measurement if sensor fitted (calculated if not)**Reduced to 26 cm / 10 Water Gauge when used with flow probe#Operating at maximum possible range may affect sensor life and accuracySensor TypesLancom analyzers use the following sensors in order to measure gas concentration TypeGasElectrochemicalCO Low, CO High, CO Low H2 compensated, O2, NO, NO2, SO2 and H2 SInfraredCO2 Pellistor/CatalyticCxHyEasy access sensorsEach sensor is installed in its own uniqueposition.

3 Replacing a sensor is a simpleprocess and will take only a few the side panel for access, swap thesensor gas & ambient temperatureThe analyzer takes a direct thermocoupletemperature measurement of the flue gas,and has an ambient temperature are required for making accuratecombustion efficiency the way Convenient catchpot - visibleand accessibleThe side-mounted catchpot is both fullyprotected and highly visible for rapid checking,removal and record ofmeasurement dataThe built-in thermal printer provides animmediate record of the measurement data. Allessential information including date and timeare POWER STATIONBOILER NO 2 MAIN SITE--------------------------------Type of fuel :Light fuel OilDry analysisO2 normalisation: off-----------------------------------Da te: : 10:23----------------------------------- T ambient : 25 CT gas : 266 CTg - Ta : 241 CCO : 2055ppm 55mg/Nm3SO2: 105 ppmNO2: 43 ppmNO : 272 ppmO2: %CxHx : %H2S : 742 ppmCO2: %NOx : 315 ppmVelocity : m/sFlue Temp.

4 : 266 CFlow : 36 %loss : %excess air %water : %O2 norm : %--------------------------------SAMPLE POINT E34 BNew micro-sensor technology used in the Lancom III, enablesdirect measurement of CO2 in flue combination of this revolutionary CO2 sensor with themeasurement capability offered by the flow probe, can givequantitative information on greenhouse gas CO2 Measurement capabilityAutomatic Sensor ProtectionAuto Purge of sensors on system shutdownClears system of corrosive flue overrange protectionAutomatically purges low CO sensor and switches to high rangemeasuring mode, if high levels of CO are LCD user interfaceThe analyzer is fitted with a full function, sealed alpha-numericbacklit LCD and user portable flue gas monitoringClip-in filters - visible andquick to changeThe chemical and particulate filters are mountedon the side of the instrument. Visibleinspection and replacement is rugged case design protects all componentsfrom is simple via the menu driven diagnostic checks are run continuously onsensor life and calibration status together withbattery servicingLong life rechargeablebatteryRechargeable batteries give up to 8 hourscontinuous operation.

5 A power supply cable isis supplied for mains power operation andbattery and measure withinminutesSimply switch on, an automatic zero calibrationis performed by the analyzer. Plug in thesample probe and take real-time gas readings ina matter of following features are standard on all instruments:Standard Sample ProbeBuilt-in Thermal PrinterData LoggingRS 232 or RS 422 Serial Communications InterfaceCarrying CaseThe user selects which gases (between 3 and 9) and options are the analyzerDraft Measurement - internal stack pressure in hPa or inches water gaugeFlow Measurement - flue gas velocity, flow rate and mass emissions rateSmoke Measurement - readings to Bacharach smoke scalesRange of Sample Probes - Smoke, Flow, DrySampler* and High TemperatureInsight Data Acquisition Software system - simple-to-use Windows reporting softwareAnalogue outputs (12 current loops, independently user configurable)Wake and Sleep facility (Semi-continuous monitoring ) - cyclical measurementDual language display options - English, French, German, Italian, Spanish & PolishOptions & AccessoriesInsight - Data Acquisition &Analysis SoftwareInsight is a Windows based data acquisitionsoftware program, used for loggingmeasurement data directly from a Lancomportable can be analyzed either in real time or duringreview of stored range of statistical and graphical tools, allowthe user to perform measurements, manipulatedata, present and print Information ref.

6 PDS 205 Sample ProbesA wide range of sample probes suitable forspecific application and measurementrequirements are Information ref. PDS 198 Wake and SleepSemi-continuous monitoring can be achievedby cyclically sampling and logging gasconcentrations over a period of time. This isachieved by alternate wake and sleep settings include wakeup interval, numberof samples between wakeup, sample intervaland first wakeup.*US Patent No. 6782767 Integral sample conditioningThe gas sample is drawn into the analyser via a sample probeand hose connected to the input connection on the frontpanel of the analyser. The sample enters the water catchpotwhere residual water is removed. The sample gas is thenpassed through a micron particulate out damaging chemicals -prolonging sensor lifeAfter removing flow and pressure variations in the sampleflow, the gas is routed to the sensor manifolds. To ensurethat the CO and CxHy sensors are not poisoned by other gasesin the sample, it is fed through a chemical filter prior to beingrouted to these sensors.

7 This action ensures longer sensor lifeand higher protectionTo protect the COLow sensor from high levels of CO(normally levels >2000ppm), a dedicated purge pump isautomatically triggered which blows ambient air to protect thesensor ensuring optimum recovery time and maximum accuracy and longevityTo maintain sensor integrity, they are purged with fresh aireach time the analyzer is switched on or off. For accuracythey are calibrated on switch on with ambient Gas Probe InletView showing measurement sensorsHow the analyzer works ?O2 NONO2SO2 COLH2 SCxHyCOHCO21324567891011 Min of 3 to max 9 gases in total, from a selection of 9 gasesProbe length options - , , , , , , 5, , 10ftAlternative probes available - Refer to Data Sheet Reference PDS198 for detailsHose length options - 3 m/10 ft or 10 m/33 ftDraught MeasurementFlow Measurement, probe length options - , , , , , , ftSmoke Measurement, probe length options - , , m/1, , ftInsight Data Acquisition Software system - Refer to Data Sheet Reference PDS205 for detailsAnalogue outputs (12 current loops, independently configurable)Wake and Sleep facility (Semi-continuous monitoring )Language display optionsSpecificationsPDS206/10/05 DisplayKeypadIndicatorsPower SupplyAmbient TemperatureCaseDimensionsWeightStandard AccessoriesOptionsFull function alphanumeric/graphic LCDwith backlight40 x 8 Matrix Liquid CrystalTactile membrane (integral with display)functions keys and cursorsLED type for ON (Power)

8 , Stand-by,Service, Charge, Low Batt., Fault95-265 V 10%, 50-60 Hz, 30 WattsRechargeable battery 2 x 6 V 4 Amp. hoursTypical 8 hr. operation, dependenton options fitted-5 C to 45 C (+23 F to 113 F)Medium density blended polyethylene453 x 120 x 245 mm ( x x inches)6 kg (13 lb)Integral water catchpot and filtersRechargeable lead acid battery (internal)Mains power supply cableProbe handle, Hose and Probe pipe(Lengths listed below under options)Carrying caseThermal printerData loggingContinuous Product Development may make it necessary to change these details without noticeLand Instruments International has a comprehensive range of Combustion andEnvironmental monitoring 198 - LANCOMS ample ProbesPDS 205 - Insight DataAcquisition SoftwareFurther InformationPolandLand Instruments Sp. z Michalowskiego 5/231-126 KrakowTelephone: +48 (0) 12 632 82 62 Facsimile: +48 (0) 12 632 24 74E-Mail: Instruments InternationalStubley Lane, DronfieldS18 1 DJTelephone: +44 (0) 1246 417691 Facsimile: +44 (0) 1246 290274E-Mail: Instruments International10 Friends LaneNewtown, PA 18940-1804 Telephone: +1 215 504 8000 Toll Free: (in USA) 800 523 8989 Facsimile: +1 215 504 0879E-Mail: Instruments Sarl7 Parc des Fontenelles78870 BaillyTelephone: +33 (0)1 30 80 89 20 Facsimile: +33 (0)1 30 80 89 21E-Mail: 2003 - 2005 Land Instruments InternationalApproval applies to products designed andmanufactured in the UKApproval applies in the USAM exicoLand Instruments InternationalAv.

9 Horacio 1132 Planta Baja B Col. Polanco, 11550 Telephone: +52 (0) 55 5281 1165 Facsimile: +52 (0) 55 5281 5364E-Mail: Instruments SrlVia dell Industria, 220037 Paderno Dugnano, MilanoTelephone: +39 02 91 08 0020 Facsimile: +39 02 99 04 0418E-Mail: ETV VerifiedTechnology (Report Sept. 2000)