Example: barber

PORTABLE TANK MEASURING SYSTEM

Always thinking the safety and environment for youType approved by CE(BV), USCG, ABS & the Korea AdministrationPORTABLE TANKMEASURING SYSTEMWe always thinking the safety TANKTECH, as a safety equipment s special manufacturer for the flammable fueltanks and marine cargo tanks has pursued one road since its is provided with total SYSTEM rendering specifications in planning and after servicefor maintenance after delivery so that it may perform its duties in carrying out suchdiversified projects such as tanker for oil product, tanker for chemical and productcarrier, etc.

We always thinking the safety and environment for you www.tanktech.co.kr Type approved by CE(BV), USCG, ABS & the Korea Administration PORTABLE TANK MEASURING SYSTEM

Tags:

  Portable, System, Measuring, Tanks, Portable tank measuring system

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of PORTABLE TANK MEASURING SYSTEM

1 Always thinking the safety and environment for youType approved by CE(BV), USCG, ABS & the Korea AdministrationPORTABLE TANKMEASURING SYSTEMWe always thinking the safety TANKTECH, as a safety equipment s special manufacturer for the flammable fueltanks and marine cargo tanks has pursued one road since its is provided with total SYSTEM rendering specifications in planning and after servicefor maintenance after delivery so that it may perform its duties in carrying out suchdiversified projects such as tanker for oil product, tanker for chemical and productcarrier, etc.

2 Throughout the quality of the project must be the prime sources to attract more customers, andwe are trying to the utmost to make our customers satisfy themselves with our safetyworkmanship in the of InstallationShut On/Off Valve Model : TVC-02 TANKTECH PORTABLE Tank MEASURING SYSTEM Useful MEASURING jobs on deck of tanker OIL : FREQUENT BEEP GAS : INTERMITTENT BEEP WATER : CONTINUOUS BEEPOFF ONDISPLAYMODELMFG. NOTFC-01-0001T2000-TFCMADE IN KOREAMFG. DATE1999. 10. 08 Compliance rulesEquipment typeFunctionCompliance withClosed type PORTABLE oil / water interface detector (UTI)Ullage levelSOLAS 1974, REGULATION 60 PARAGRAPH 7 IMO, MSC / (IBC BCH CODE)IMO MARPOL73 / 78 ANNEX I-CHAP II - REGULATION 15, (3) (b)IMO RESOLUTION (XIII) ANNEX gaugingOil - water interface levelCargo liquid sampling deviceLiquid samplingOCIMF, API STANDARDRESTRICTED WITH CLOSED SAMPLING OF LIQUIDSAMPLINGI nert gas sampling hose & adaptorOxygen and flammable gas concentration measuringIMO REQUIREMENT ON TANKER SAFETY AND POLLUTIONPREVENTION, 1978-RESOLUTION (XI)

3 , gaugeInert gas pressure gaugingIMO REQUIREMENT ON TANKER SAFETY AND POLLUTIONPREVENTION, 1978-RESOLUTION (XI), (b)Tank bottom liquid and sedimentschecking deviceTank bottom dryness & sediment checking IMO REQUIREMENT ON TANKER SAFETY AND POLLUTIONPREVENTION, 1978-RESOLUTION (XI) on / off valveVapor lock installation of PORTABLE tank MEASURING systemIMO MARPOL 1973 / 78 ANNEX I, REGULATION 13b (3)SOLAS 1974, REGULATION 60 PARAGRAPH 7(REQUIREMENT OF CLOSED ULLAGE SYSTEM )IMO MARPOL73 / 78 ANNEX I-CHAP II - REGULATION 15, (3) (b)SOLAS REGULATION 62, PARAGRAPH 17- Chemical Tankers- Crude Oil Tankers- Clean Product Tankers- Offshore storage tanks - Slop tanks - Tank Farm Storage and tanks Slop- Solvents tanks FarmsAPPLICATIONTANKTECH PMSSERIESTANKTECH PMSSERIESC hart for Restricted TypeTANKTECH PORTABLE Tank MEASURING SYSTEM PORTABLE TANK MEASURING SYSTEMRESTRICTED TYPE PORTABLE OIL / WATER INTERFACE DETECTORMODEL T2000-TFS-01 TOP CONN.

4 : PF 2 -1/4 TAPFUNCTION: ULLAGE,TEMPERATUREOIL / WATER INTERFACE(1)(2)(4)(3)(5)(6)(6)(6)CARGO SAMPLING DEVICEMODEL T2000-TSS-02 TOP CONN. : PF 2 -1/4 TAPFUNCTION: LIQUID SAMPLINGINERT GAS SAMPLING HOSE &ADAPTOR MODEL T2000-TOS-01 TOP CONN. : PF 2 -1/4 TAPFUNCTION : ADAPTOR FOR OXYGENMEASURINGTANK BOTTOM LIQUID AND SEDIMENTS CHECKING DEVICEMODEL T2000-TLS-01 TOP CONN. : PF 2 -1/4 TAPFUNCTION: TANK BOTTOMDRYNESSCHECKING & GAUGEMODEL T2000-TPG-01 TOP CONN. : PF 2 -1/4 TAPFUNCTION: INERT PRESSUREGAUGINGSHUT ON / OFF VALVEMODEL: TVC-02 TOP CONN. : PF 2-1/4 TAPFLANGE CONN.: 80A JIS 5K : VAPOR LOCK INSTALLATION OF PMSMAIN TANK GAUGING STATION(ULLAGE GAUGING & SAMPLING)SHUT ON / OFF VALVEMODEL: TVC-04 TOP CONN.

5 : PF 2-1/4 TAP FOR ULLAGE GAUGING: TAP FOR SAMPLINGFLANGE CONN.: 100A JIS 5K : VAPOR LOCK INSTALLATION OF PMSMAIN TANK GAUGING STATION(ULLAGE GAUGING & SAMPLING)SHUT ON / OFF VALVEMODEL: TVC-01 TOP CONN. : PF 2-1/4 TAP FLANGE CONN.: 50A JIS 5K : VAPOR LOCK INSTALLATION OF PMSBOTTOM DRYNESS CHECKING, with the PORTABLE type manufactured a suitable use, to measure the various data in tankTANKTECH for Gas-tight Type TANKTECH PORTABLE Tank MEASURING SYSTEM (1)(2)GASTIGHT TYPE PORTABLE OIL / WATER INTERFACE DETECTORMODEL T2000-TFC-01 TOP CONN. : PF 2 -1/4 TAPFUNCTION: ULLAGE,TEMPERATUREOIL / WATER INTERFACESHUT ON / OFF VALVEMODEL: TVC-02 TOP CONN.

6 : PF 2-1/4 TAPFLANGE CONN.: 50A JIS 5K : VAPOR LOCK INSTALLATION OF PMSMAIN TANK GAUGING STATION(ULLAGE GAUGING & SAMPLING)(6)(6)SELF CLOSING VALVEMODEL: TVC-03 TOP CONN. : PF 2-1/4 TAPFLANGE CONN.: 80A JIS 5K : VAPOR LOCK INSTALLATION OF PMSMAIN TANK GAUGING STATION(ULLAGE GAUGING & SAMPLING)CARGO LIQUID SAMPLING DEVICEMODEL T2000-TSS-01 TOP CONN. : PF 2 -1/4 TAPFUNCTION: CLOSED LIQUID SAMPLINGDURING OPERATIONLIQUID AUTO DRAIN BY 2 WAY VALVETANKTECH PMSSERIESR estricted Type PORTABLE Oil / Water Interface Detectorfor Ullage, oil / water interface & temperature gauging PORTABLE TANK MEASURING SYSTEM -High accuracy & Responsibility-Protect operator-Prevent environmental pollution-Easy construction-Easy operation & maintenanceBENEFITSRESTRICTED TYPEMODEL: T2000-TFS-01 GENERALT ankers shall be provided with an effective oil/water interface detectors approved bythe Administration.

7 And this device shall be provided for a rapid and accurate determination of theoil/water interface in slop tanks and shall be available for use in other tanks where theseparation of oil and water is effected and from which it is intended to dischargeeffluent direct to the device should be tested according to the IMO Resolution MEPC 5, (XIII) for theprevention of pollution from of ullage, interface detectionIndication of level divided by ullage and interfaceTape lengthTape graduationTape resolutionTape accuracyDiameter of probeMinimum detectable levelAmbient temperature rangeTemperature sensor measurement rangeTemperature measurement resolutionAccuracy over calibration rangeTemperature reading modeLCD displayTop Coupling (Connection)WeightOverall dimensions (H X W X T)

8 BatteryIntrinsically safe type+ / - 2 mmVisible and Audible15 M / 30 M / 40 MMetric1 mm+ / - mm23 mm10 mm-20 C to 70 C-20 C to 110 C+ / - C ( 0 C to 70 C ) C(Celsius)2 Line 16 characterPF 2-1/4 kg645 X 315 X 150 mm9 Volt ( Model : MN1604)Ex ia IIB T4In/Out : Epoxy nylon coating Color : BlackThickness : (In / Out Side ) : Aluminum plate ( JIS - 6061 ) TANKTECH Type PORTABLE Oil / Water Interface Detectorfor Ullage, oil / water interface & temperature gauging PRINCIPLED etection of UllageThe detection method is based upon the principle of detecting achange in impedance using ultra sonic technology.

9 Detection of interfaceThe detection method is based upon MEASURING the differentvoltage according to conductivity of measurementTemperature measurement is obtained by the output voltageof the built-in semiconductor EASY DISTINGUISHUser can easily knowthe location of sensorprobe by beep and of detectionBeepLCD IndicationIntermittent beepGas zone- GAS -Frequent beepOil zone- OIL -Continuous beepWater zone- WATER -DISPLAYTEMP : C- GAS -DISPLAYTEMP : C- OIL -DISPLAYTEMP : C- WATER -TANKTECH PMSSERIESWe always thinking the safety Gas-tight Type PORTABLE Oil / Water Interface Detectorfor Ullage, oil / water interface & temperature gauging - Displays Oil, Gas, Water & Temperature at once- Gas-tight seals toxic gases- Sample one switch operation on / off- Adaptors for maincompetitor s vapor valvesBENEFITSGENERALT ankers shall be provided with an effective oil/water interface detectors approved bythe Administration.

10 And this device shall be provided for a rapid and accurate determination of theoil/water interface in slop tanks and shall be available for use in other tanks wherethe separation of oil and water is effected and from which it is intended to dischargeeffluent direct to the device should be tested according to the IMO Resolution MEPC 5, (XIII) for theprevention of pollution from of ullage, interface detectionIndication of level divided by ullage and interfaceTape lengthTape graduationTape resolutionTape accuracyDiameter of probeMinimum detectable levelAmbient temperature rangeTemperature sensor measurement rangeTemperature measurement resolutionAccuracy over calibration rangeTemperature reading modeLCD displayTop CouplingWeightOverall dimensions (H X W X T)BatteryIntrinsically safe type+ / - 2 mmVisible and Audible15 M / 30 M / 40 MMetric1 mm+ / - mm23 mm10 mm-20 C to 70 C-20 C to 110 C+ / - C ( 0 C to 70 C )


Related search queries