Eaton Low-voltage circuit breakers Power Defense circuit breakers Product guide A globally rated platform from Eaton Power DefenseE molded case The Power Defense circuit breakers PXR electronic trip units are feature the Power XpertT Release equipped with the latest micro- circuit breakers (MCCBs) and (PXR) electronic trip units, offering processor technology including insulated case circuit breakers premium protection and communi- industry-first advanced algorithms (ICCBs) are globally certified to cation features allowing you to use that notify you when your Power fewer components and a simplified distribution circuit breaker needs meet your local requirements, design while keeping your system to be maintained or replaced.

fault protection • Expanded ground fault setting options improve coordination capabilities • Combined functionality to trip and/or alarm, including a pre-alarm option via a programmable relay, provides maximum protection options and system uptime • An OFF setting also provides flexibility in testing, troubleshooting and inventory management

Tags:

  Management, Electrical, Fault

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Power Defense circuit breakers - Electrical and Industrial

1 Eaton Low-voltage circuit breakers Power Defense circuit breakers Product guide A globally rated platform from Eaton Power DefenseE molded case The Power Defense circuit breakers PXR electronic trip units are feature the Power XpertT Release equipped with the latest micro- circuit breakers (MCCBs) and (PXR) electronic trip units, offering processor technology including insulated case circuit breakers premium protection and communi- industry-first advanced algorithms (ICCBs) are globally certified to cation features allowing you to use that notify you when your Power fewer components and a simplified distribution circuit breaker needs meet your local requirements, design while keeping your system to be maintained or replaced.

2 They empowering you to build and connected, your equipment and also have the embedded ability employees protected, and your to accurately measure energy design systems that can be customers informed. The PXR trip consumption with no additional used anywhere in the world. unit family has models that will meters or equipment, delivering Wherever Eaton does business, cover all of your needs, including critical data about your Power fully programmable models that distribution system and energy Power Defense circuit breakers enable ultimate customization and use in your facility. are there, backed by Eaton's flexibility, as well as value models Whether you're building production global support and fulfillment that offer all of the benefits of capacity or a legacy, the green electronic trip units, with simple network, with the right setup and coordination.

3 Factory of the future or the newest high rise on the next resources in place to horizon, Power Defense circuit minimize your project lead- breakers will serve as guardian time and maximize your and protector as your ideas are realized in concrete and steel. uptime. Integrating new products can be a challenge, which is why the Power Defense circuit breakers are available with online instructions, support and a product selector. These unique tools can help you engineer and deliver your projects quickly, ultimately helping to improve your bottom line. Power Defense circuit breakers a globally rated platform from Eaton Molded case circuit breaker Insulated case circuit breaker EATON Power Defense circuit breakers Power Defense circuit breaker portfolio Frame PD-1.

4 Dimensions Maximum NEMA voltage Interrupting capacity Trip unit options Through-cover accessories W x H x D inches 347 Y/600 Vac/250 Vdc at 480 Vac (kAIC) T/M fixed fixed ( x x mm) 18, 25, 35, 50, 65, 85, Maximum IEC voltage 100. Current range 415 Vac/250 Vdc 15 125 A 100% UL rated options Certifications UL/CSA/CE/CCC Current limiting options Frame PD-2. Dimensions Maximum NEMA voltage Interrupting capacity Trip unit options Through-cover accessories W x H x D inches 600 Vac/250 Vdc at 480 Vac (kAIC) T/M fixed fixed Available with 2 PXR. ( x x mm) 25, 35, 50, 65, 85, 100 PXR 10 communication relays Maximum IEC voltage PXR 20. Current range 690 Vac/250 Vdc 100% UL rated options 1 Relay with Modbus RTU.

5 PXR 20D. 15 225 A PXR 25. Certifications Current limiting UL/CSA/CE/CCC options Electronic protection LSI, LSIG. Frame PD-3. Dimensions Maximum NEMA voltage Interrupting capacity Trip unit options Through-cover accessories W x H x D inches 600 Vac/250 Vdc at 480 Vac (kAIC) T/M fixed adjustable Available with 2 PXR. ( x x mm) 25, 35, 50, 65, 85, 100 PXR 10 communication relays Maximum IEC voltage PXR 20. Current range 690 Vac/250 Vdc 100% UL rated options Field-interchangeable trip units PXR 20D. 45 600 A PXR 25. Certifications Current limiting UL/CSA/CE/CCC options Electronic protection LSI, LSIG, ALSI, ALSIG. Frame PD-4. Dimensions Maximum NEMA voltage Interrupting capacity Trip unit options Through-cover accessories W x H x D inches 600 Vac/250 Vdc at 480 Vac (kAIC) T/M fixed adjustable Available with 2 PXR.

6 ( x x mm) 35, 50, 65 PXR 10 communication relays Maximum IEC voltage PXR 20. Current range 690 Vac/250 Vdc 100% UL rated options Field-interchangeable trip units PXR 20D. 300 800 A PXR 25. Certifications UL/CSA/CE/CCC Electronic protection LSI, LSIG, ALSI, ALSIG. Frame PD-5. Dimensions Maximum NEMA voltage Interrupting capacity Trip unit options Field-interchangeable W x H x D inches 600 Vac/250 Vdc at 480 Vac (kAIC) PXR 20 accessories ( x x mm) 50, 65, 85, 100, 150 PXR 20D Available with 3 PXR. Maximum IEC voltage PXR 25. Current range 690 Vac/250 Vdc 100% UL rated options communication relays 320 1200 A (UL) Electronic protection Field-interchangeable trip units 320 1600 A (IEC) Certifications LSI, LSIG, ALSI, ALSIG.

7 UL/CSA/CE/CCC. Frame PD-6. Dimensions Maximum NEMA voltage Interrupting capacity Trip unit options Field-interchangeable W x H x D inches 600 Vac/250 Vdc at 480 Vac (kAIC) PXR 20 accessories ( x x mm) 65, 85, 100 PXR 20D Available with 3 PXR. Maximum IEC voltage PXR 25. Current range 690 Vac/250 Vdc 100% UL rated options communication relays 700 2500 A Electronic protection Field-interchangeable Certifications LSI, LSIG, ALSI, ALSIG trip units UL/CSA/CE/CCC. Frame PD-NF. Dimensions Maximum NEMA voltage Interrupting capacity Trip unit options Field-interchangeable accessories W x H x D inches 600 Vac at 480 Vac (kAIC) PXR 20 Available with 3 PXR. ( x x mm) 42, 50, 65 PXR 25 communication relays (with cassette) Maximum IEC voltage 690 Vac 100% UL rated Electronic protection Field-interchangeable trip units Current range LSI, LSIG, ALSI, ALSIG Stored energy mechanism 200 1200 A (UL 489 option) Certifications UL/CSA or CE/CCC Front connect or rear connect.

8 200 1600 A (IEC option) fixed or drawout Frame PD-RF. Dimensions Maximum NEMA voltage Interrupting capacity Trip unit options Field-interchangeable accessories W x H x D inches 480 Vac at 480 Vac (kAIC) PXR 20 Available with 3 PXR. ( x x mm) 65, 85, 100 PXR 25 communication relays (with cassette) Maximum IEC voltage 690 Vac 100% UL rated Electronic protection Field-interchangeable trip units Current range LSI, LSIG, ALSI, ALSIG Stored energy mechanism 800 3000 A (UL 489 option) Certifications UL/CSA or CE/CCC Rear connect; fixed or drawout 800 4000 A (IEC option). EATON Power Defense circuit breakers Advanced technology and features Zone selective Arcflash Reduction Enhanced ground Breaker health interlocking (ZSI) Maintenance SystemE (ARMS) fault protection Designed to reduce thermal and mechanical stress on Industry-first algorithm that distribution equipment and provides real-time evaluation of Expanded ground fault setting arc flash incident energy.

9 Breaker condition by tracking options improve coordination released during phase or Industry-leading solution and analyzing diagnostic details capabilities ground faults by enabling to reduce arc flash energy including breaker operations, the breaker closest to the released during maintenance Combined functionality to short- circuit fault levels, . fault to override customer- operations using a separate trip and/or alarm, including operational time, internal defined delay settings while circuit to provide faster than a pre-alarm option via a temperature and overloads communicating with upstream instantaneous clearing times programmable relay, provides Monitors and communicates and downstream breakers maximum protection options breaker health status, enabling Flexibility to enable system PXR trip unit displays ZSI signal and provide visual indication and system uptime predictive maintenance to avoid indication when system is by communications, remote An OFF setting also provides costly.

10 Unscheduled downtime . engaged, communicating and switch and relay, or directly on flexibility in testing, check indication when input the trip unit face troubleshooting and signal is detected, allowing inventory management network integrity testing and Adjustable ARMS settings via providing operational status LCD screen or PXPM software Versatile communications Power Xpert Protection options Cause of trip LEDs Programmable relays Manager (PXPM) software Cause of trip indication provides insights into a trip event, increasing worker safety and efficiency while troubleshooting PXRs 20, 20D and 25 include LEDs on the face of the trip unit that will pulse ON/OFF.