Transcription of POWER RELAY - 松下继电器
1 1 FTR-K1 SERIESn FEATURESl 10A, 450 VDC high-voltage switching (2 x 10A, 200 VDC switching)l Contact voltage drop: typical Inrush current 150A (capacitive load)l Compact size (L x W X H= )l 2 x 1 form Al Coil sensitivity 1W (each coil connect in series)l High insulation between contacts and coil - Insulation distance : Clearance/creepage > 6mm - Dielectric strength : 4,000 VAC - Surge strength : 10,000 V ( x 50 sec)l Plastic materials conform to UL94 flame class V-0l Flux proof, RTIIl RoHS compliant Please see page 8 for more informationActual marking does not carry the type name : "FTR" : Ordering code: FTR-J2AK012W Actual marking: J2AK012 WPOWER RELAYULTRA SMALL HIGH VOLTAGE DC RELAYFTR-J2 Seriesn PARTNUMBER INFORMATION FTR-J2 A K 012 W [Example] (a) (b) (c) (d) (e) (a) RELAY type FTR-J2 : FTR-J2-Series (b) Contact configuration A : 2 x 1 form A (c) Coil POWER K : Standard sensitivity (d) Coil rated voltage 012 : VDC Coil rating table at page 3 (e) Contact material W : Silver alloy2 FTR-K1 SERIESn SPECIFICATIONItemFTR-J2 Contact DataConfiguration2 x 1 form AMaterialSilver alloyContact resistant (initial)Max.
2 100 m at 1A, 6 VDCC ontact rating10A, 450 VDC (resistive load) (+ polarity pin 7 and 4)* each NO contact connected in series10A, 200 VDC (resistive load) (single contact) + (polarity pin 7 and 4) * for each NO contactOverload switching *10A, 500 VDC (resistive load), 50 operations* each NO contact connected in series10A, 250 VDC (resistive load) * for each NO contactMaximum carrying current12 AInrush currentPeak 150A Maximum switching voltage600 VDC, each NO contact connection in series300 VDC, each NO contactContact voltage drop (initial)Typical (at nominal contact current)LifeMechanical2M operationsElectrical10K operationsCoil DataOperate voltage (at 20 C)Maximum 70% of nominal voltageRelease voltage (at 20 C)Minimum 5% of nominal voltageOperating temperature range (no frost)-40 to +85 C Timing DataOperate (at nominal voltage)Max.
3 15ms (without bounce)Release (at nominal voltage)Max. 5ms (no diode)InsulationResistance (initial)Min. 1000M at 500 VDCD ielectric strengthBetween open contacts1,000 VAC (50/60Hz) 1minBetween contact sets1,000 VAC (50/60Hz) 1minBetween contacts and coil4,000 VAC (50/60 Hz) 1 strengthCoil to contacts10,000V/ x 50 s standard waveOtherVibration resistanceMisoperation10 to 55Hz double amplitude to 55Hz double amplitude 200m/s (11 1ms)EnduranceMin. 1,000m/s (6 1ms)WeightApproximately 26gSealingFlux proof RTIIFTR-J2 SERIESNote: Use a varistor as a protective circuit against reverse surge connected parallel to the coil. The reverse blocking voltageshould be about 3 times the value of the POWER source voltage.* Minimum switching loads mentioned above are reference values.
4 Please perform the confirmation test with actualload before production since reference values may vary according to switching frequencies, environmental conditionsand expected reliability SERIESn COIL RATINGCoil CodeRated Coil Voltage (VDC)Coil Resistance +/- 10% (Ohm) *Must Operate Voltage (VDC) *Must ReleaseVoltage (VDC) *Rated POWER (W) ( 10%) , , ,58084611022045,60015411 FTR-J2 SERIES2 coils in series (Connect RELAY coil terminal to ) See note CodeRated Coil Voltage (VDC)Coil Resistance +/- 10% (Ohm) *Must Operate Voltage (VDC) *Must ReleaseVoltage (VDC) *Rated POWER (W) ( 10%) , , ,79042311011022, single coilCoil CodeRated Coil Voltage (VDC)Coil Resistance +/- 10% (Ohm) *Must Operate Voltage (VDC) *Must ReleaseVoltage (VDC) *Rated POWER (W) ( 10%) , ,39542311011011, 1: All values in the tables are valid for 20 C and zero contact 2: Nominal voltage is different from indication of part number.
5 Please refer to the coil rating chart "single coil (10A, 200 VDC configuration)" for single coil configuration 3: Please use with nominal voltage. When energizing higher voltage to coil, please refer tocharacteristic data "coil temperature rise" and "operating range" (page 4) to set suitable voltage.* Specified operate values are valid for pulse wave voltage. 2 coils in parallel (Connect RELAY coil terminal to and to )4 FTR-K1 SERIESn CHARACTERISTIC DATAFTR-J2 SERIESTypeComplianceContact ratingULUL 50810A, 450 VDC, resistive, 10,000 cycles for series connection of each NO contact10A, 400 VDC, resistive, 10,000 cycles for series connection of each NO contact10A, 200 VDC, resistive, 10,000 cycles for each NO contactVDE043510A, 400 VDC, resistive, 10,000 cycles for series connection of each NO contact10A, 200 VDC, resistive, 10,000 cycles for each NO contactn SAFETY STANDARDS* Each NO contact connect in series* Each NO contact 5 FTR-K1 SERIESFTR-J2 SERIESn DIMENSIONSUnit.
6 Mm l Dimensionsl PC board mounting hole layout (BOTTOM VIEW)l Schematics (BOTTOM VIEW)6 FTR-K1 SERIESn CIRCUITl Load circuit and input circuit (coil sides) for 10A, 450 VDC 2 coils connect in seriesLoad circuit contact terminals have polarities (+) and (-). Coils do not have SERIESl Load circuit and input circuit (coil sides) for 10A, 450 VDC 2 coils connect in parallel(Varistor)(Note 2)BOTTOM VIEW(Varistor)(Note 3)BOTTOM VIEWNote 1: In case 2 coils are connected in series, connect coil terminal #2 to #3 on PCB circuit. In case 2 coils are connected in parallel, connect coil terminal #1 to #3 and connect coil terminal #2 to #4 on PCB. Regarding terminal number, refer to schematics 2: Please use varistor as surge protection device.
7 If varistor will not be used, the electrical life need to be 3: Varistor surge protection device should be connect parallel to coil(s). Suitable voltage of varistor is 3 times the coil 4: For max. contact life and correct functioning of the RELAY , positive polarity of load should be connected to pin 8 and pin 5. If not, damage to the RELAY can : At current loads at max. switching capacity 10A (450 VDC) correct polarity is vital for the correct and safe functioning of the SERIESn CIRCUITl Load circuit and input circuit (coil sides) for 10A, 200 VDC (dual circuits)FTR-J2 SERIESl Load circuit and input circuit (coil sides) for 10A, 200 VDC (dual circuits) 2 coils connect in seriesLoad circuit contact terminals have polarities (+) and (-).
8 Coils have no polarity.(Varistor)(Note 1)BOTTOM VIEW(Varistor) (Note 3)BOTTOM VIEWNote 1: In case 2 coils are connected in series, connect coil terminal #2 to #3 on PCB circuit. In case 2 coils are connected in parallel, connect coil terminal #1 to #3 and connect coil terminal #2 to #4 on PCB. Regarding terminal number, refer to schematics 2: Please use varistor as surge protection device. If varistor will not be used, the electrical life need to be 3: Varistor surge protection device should be connect parallel to coil(s). Suitable voltage of varistor is 3 times the coil 4: For max. contact life and correct functioning of the RELAY , positive polarity of load should be connected to pin 8 and pin 5. If not, damage to the RELAY can : At current loads at max.
9 Switching capacity 10A (200 VDC) correct polarity is vital for the correct and safe functioning of the SERIESFTR-J2 SERIES1. General Informationl All signal and POWER relays produced by fujitsu Components are compliant with RoHS directive 2002/95EC including Cadmium as used in electrical contacts is exempted from the RoHS directives on October 21st, 2005. (Amendment to Directive 2002/95/EC)l All of our signal and POWER relays are lead-free. Please refer to Lead-Free Status Info for older date codes at: Lead free solder plating on RELAY terminals is , unless otherwise specified. This material has been verified to be compatible with PbSn assembly Recommended Lead Free Solder Profilel Recommended solder Compliance and Lead Free Information3.
10 Moisture Sensitivityl Moisture Sensitivity Level standard is not applicable to electromechanical relays, unless otherwise Tin Whiskersl Dipped SnAgCu solder is known as presenting a low risk to tin whisker development. No considerable length whisker was found by our in house highly recommend that you confirm your actual solder conditionsFlow Solder condition:Pre-heating: maximum 120 CSoldering: dip within 5 sec. at 260 C solder bathSolder by Soldering Iron:Soldering Iron Temperature: maximum 360 CDuration: maximum 3 SERIESF ujitsu Components International Headquarter OfficesFTR-J2 SERIESJ apanFujitsu Component LimitedGotanda-Chuo Building3-5, Higashigotanda 2-chome, Shinagawa-kuTokyo 141, JapanTel: (81-3) 5449-7010 Fax: (81-3) 5449-2626 Email: and South AmericaFujitsu Components America, E.