POWERCUBE - CENTRAL EXTRACT SYSTEM

TECHNICAL DATA MAINS VOLTAGE MODELS EXTRACT Volume : 720 m3/h (HIGH) : 220 m3/h (LOW) sound Volume* : See Table Below Voltage : 230-240v AC~ Frequency : 50 Hz Wattage : 200W (HIGH) : 105W (LOW) Max. Temp. : 50 C Weight : kg ( POWERCUBE ONLY) Max Pressure : 450 pa CLASS 1 PRODUCT MUST BE EARTHED * : Independent Tests 14-7-2003 DIMENSIONS POWERCUBE - CENTRAL EXTRACT SYSTEM POWERCUBE - CENTRAL EXTRACT SYSTEM Measured in mm A : 345 B : 280 C : 335 : 150 Standard : Unit can be wired to operate continuously at low speed with boost via 2 speed switch (ANC 812A - not supplied) or from multiple 2 pole (bathroom / en-suite light) switches. Alternatively can be wired to operate single speed on and off at any of the 4 speeds.

TECHNICAL DATA MAINS VOLTAGE MODELS TRIPLEVENT CENTRAL EXTRACT SYSTEM • Extract Volume : 240 m3/h (HIGH): 120m3/h (LOW) • Sound Volume *: 19.0dB (A)@3m (HIGH): 12.0dB (A)@3m

Tags:

  System, Central, Extracts, Sound, Powercube central extract system, Powercube

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of POWERCUBE - CENTRAL EXTRACT SYSTEM

1 TECHNICAL DATA MAINS VOLTAGE MODELS EXTRACT Volume : 720 m3/h (HIGH) : 220 m3/h (LOW) sound Volume* : See Table Below Voltage : 230-240v AC~ Frequency : 50 Hz Wattage : 200W (HIGH) : 105W (LOW) Max. Temp. : 50 C Weight : kg ( POWERCUBE ONLY) Max Pressure : 450 pa CLASS 1 PRODUCT MUST BE EARTHED * : Independent Tests 14-7-2003 DIMENSIONS POWERCUBE - CENTRAL EXTRACT SYSTEM POWERCUBE - CENTRAL EXTRACT SYSTEM Measured in mm A : 345 B : 280 C : 335 : 150 Standard : Unit can be wired to operate continuously at low speed with boost via 2 speed switch (ANC 812A - not supplied) or from multiple 2 pole (bathroom / en-suite light) switches. Alternatively can be wired to operate single speed on and off at any of the 4 speeds.

2 Timer : Unit is wired to operate continuously at low speed with boost via up to 4 standard remote switches bathroom & en-suite light switches. This model contains integral relay to eliminate electrical backfeed and 2 - 25 minutes over-run timer before unit drop back to low speed. Both low and high speeds are selectable from 4 speeds. Humidistat : Unit is wired to operate continuously at low speed with boost via integral humidistat and up to 4 standard remote switches bathroom & en-suite light switches. This model contains integral relay to eliminate electrical backfeed and 2 - 25 minutes over-run timer before unit drop back to low speed. Both low and high speeds are selectable from 4 speeds. FAN OPERATION sound LEVELS SPEED EXTRACT WATTS 63 125 250 500 Lw,dB(Lin) LwA,dB(A) LpA,dB(A) From Lp Trickle 230m3/h 105W Medium 340m3/h 117W Boost / High (Std)

3 500m3/h 135W Extra High 725m3/h 200W 58 PERFORMANCE GRAPH For POWERCUBE CENTRAL EXTRACT SYSTEM 600 500 400 300 200 100 0 100 200 300 400 500 600 700 800 m3/h A B C TOP Efficient Extraction for Applications Requiring Multi Room Ventilation EXTRACT Range 720m3/h (201 l/s) to 220m3/h (61 l/s) Integral Relay For Switching From Up To 4 (Light) Switches (Not Standard Model) Suitable As Whole Flat EXTRACT SYSTEM (BRE Digest 398) Acoustic Lined For Whisper Quiet sound Levels Selection of 4 Speeds Single Spigot For Flexible Ventilation Solutions 3 Year On-Site Warranty on All Models SPECIFICATION & INSTALLATION OVERVIEW POWERCUBE - CENTRAL EXTRACT SYSTEM Code Model PWC 750 Standard - High / Low Speed PWC 750 TST Continuous Trickle - Multi Switch Boost & Timer PWC 750 HTST Continuous Trickle - Multi Switch Boost, Humidistat & Timer Constructed from zintec steel with a white enamel finish, the POWERCUBE offers an ideal ventilation solution to application requiring top class multi-room extraction from one unit.

4 The product is built with a highly efficient double inlet blower and ball bearing motor to BS EN60335. It is also acoustically lined to provide whisper quiet sound levels. The unit extracts from multiple rooms via one 150mm spigot located on the side and exhausts via a 150mm spigot located on the opposite. This design offers the ability to install in lofts, cupboards etc and other locations where it would prove inconvenient to install multiple duct runs. Simply run a 150mm duct along the most suitable route and use T adaptors in to the points. The POWERCUBE CENTRAL EXTRACT SYSTEM is designed to comply with BRE Digest 398. PRODUCT SUMMARY MODELS AVAILABLE 59 POWERCUBE - CENTRAL EXTRACT SYSTEM TECHNICAL DATA MAINS VOLTAGE MODELS EXTRACT Volume : 240 m3/h (HIGH) : 120m3/h (LOW) sound Volume* : (A)@3m(HIGH) : (A)@3m(LOW) Voltage : 230-240v AC~ Frequency : 50 Hz Wattage : 90W Max.

5 Temp : 50 C Weight : kg (FAN ONLY) Max Pressure : 300 pa Double Insulated * : Independent Tests 14-7-2003 DIMENSIONS TRIPLEVENT - CENTRAL EXTRACT SYSTEM TRIPLEVENT - CENTRAL EXTRACT SYSTEM A B Measured in mm A : 337 B : 294 C : 74 D : 121 : 100 0 40 80 120 160 200 240 Pa 350 300 250 200 150 100 50 0 PERFORMANCE GRAPH For TRIPLEVENT CENTRAL EXTRACT SYSTEM Single Speed : The unit will be activated by one of the separate switches / remote room switches (not supplied). When the switch is turned off, the unit will continue to run at high speed for 2 - 25 minutes, dependant on the timer adjustment. The fan unit will then switch itself off. Twin Speed : The unit is designed to operate continuously at low speed.

6 High speed is activated by one of the separate switches (not supplied). When the switch is turned off, the unit will continue to run at high speed for 2 - 25 minutes, dependant on the timer adjustment. The fan unit will then switch back to low speed. Twin Speed Kit : The BAR 240 TST operates as the twin speed described above. It comes with the Triplevent unit (TVT 240 TST), 10 metre length of 100mm flexible ducting (ANC 505B), 3 adjustable airvents (ANC 819A) and 1 external fixed louvred grille (ANC 410D). FAN OPERATION C C D 60 Efficient Ventilation of 2 or 3 separate toilets, bath rooms and en-suites from one unit EXTRACT Rate 240m3/h (67 l/s) (BOOST) 120m3/h (33 l/s) (TRICKLE) Integral Relay For Switching From Up To 3 (Light) Switches (Not Standard Model) Continuous Trickle Model Suitable As Whole Flat EXTRACT SYSTEM (BRE Digest 398)

7 Motor Mounted On Rubber Bushes - Significantly Reduces Vibration 3 Year on-Site Warranty on All Models SPECIFICATION & INSTALLATION OVERVIEW TRIPLEVENT - CENTRAL EXTRACT SYSTEM Code Model TVT 240 Standard - High / Low Speed TVT 240 SST Single Speed - Over - run Timer TVT 240 TST Twin Speed - Continuous Trickle with Boost and Over-run Timer BAR 240 TST Twin Speed - Continuous Trickle with Boost and Over-run Timer including 100mm ducting, grille and 3 airvents The TripleVent is, as its name suggests, designed to EXTRACT from up to 3 separate toilets, bathrooms or en-suites. Made from a high gloss ABS, the unit comes in single or twin speed models and is specifically designed for in-line installation. The unit should be installed with loft space and can be mounted on ceiling joists using the bracket supplied, or wall mounted on one of the gable ends.

8 Interconnection to the main unit and the 3 EXTRACT points is via 100mm flexible ducting and 3 airvents mounted in the ceiling of the rooms to be ventilated. The ducting (ANC 505B) and airvents (ANC 819A) are only supplied as part of the BAR 240 TST TripleVent Kit. EXTRACT from the CENTRAL unit can be made through the roof, gable end wall or soffit as required. EXTRACT is via 100mm flexible (ANC 819A) or rigid ducting (ANC 531A) with a suitable termination point. PRODUCT SUMMARY MODELS AVAILABLE 61 TRIPLEVENT - CENTRAL EXTRACT SYSTEM TECHNICAL DATA MAINS VOLTAGE MODELS EXTRACT Volume : 720 m3/h (HIGH QVT750) : 220 m3/h (LOW ALL MODELS) sound Volume* : See Table Below Voltage : 230-240v AC~ Frequency : 50 Hz Wattage : 200W (HIGH) : 105W (LOW) Max. Temp. : 50 C Weight : kg (QUADVENT ONLY) Max Pressure : 450 pa CLASS 1 PRODUCT MUST BE EARTHED * : Independent Tests 14-7-2003 DIMENSIONS QUADVENT - CENTRAL EXTRACT SYSTEM QUADVENT - CENTRAL EXTRACT SYSTEM A B Measured in mm A : 345 B : 280 C : 335 : 100 1 : 150 Standard : Unit can be wired to operate continuously at low speed with boost via 2 speed switch (ANC 812A - not supplied).

9 Alternatively can be wired to operate single speed on and off at any of the 4 speeds. Timer : Unit is wired to operate continuously at low speed with boost via up to 4 standard remote switches ie, bathroom & en-suite light switches. This model contains integral relay to eliminate electrical backfeed and 2 - 25 minutes over-run timer before unit drop back to low speed. Both low and high speeds are selectable from 4 speeds. Humidistat : Unit is wired to operate continuously at low speed with boost via integral humidistat and up to 4 standard remote switches ie, bathroom & en-suite light switches. This model contains integral relay to eliminate electrical backfeed and 2 - 25 minutes over-run timer before unit drop back to low speed.

10 Both low and high speeds are selectable from 4 speeds. FAN OPERATION sound LEVELS SPEED EXTRACT WATTS 63 125 250 500 Lw,dB(Lin) LwA,dB(A) LpA,dB(A) From Lp Trickle 230m3/h 105W Medium 340m3/h 117W Boost / High (Std) 500m3/h 135W Extra High (QVT750) 725m3/h 200W 62 PERFORMANCE GRAPH For QUADVENT CENTRAL EXTRACT SYSTEM 600 500 400 300 200 100 0 100 200 300 400 500 600 700 800 m3/h SIDE C 1 Efficient Extraction for Applications Requiring Multi Room Ventilation EXTRACT Range (Model Dependant) 720m3/h (201 l/s) to 220m3/h (61 l/s) Integral Relay For Switching From Up To 4 (Light) Switches (Not Standard Model) Suitable As Whole Flat EXTRACT SYSTEM On Properties Up To 700m3 (BRE Digest 398)