PowerTech ™ 4024T Diesel Engine - John Deere

Photographs may show non-standard equipment. PowerTech 4024T Diesel EngineGenerator Drive Engine Specifications 4024T shownCertifications Non-Emissions CertifiedDimensionsGeneral dataModel4024TF220 Number of cylinders4 Displacement - L (cu in) (146)Bore and Stroke-- mm (in)86 x 105 ( x )Compression :1 Engine TypeIn-line, 4-CycleAspirationTurbochargedLength - mm (in)662 ( )Width - mm (in)566 ( )Height-- mm (in)772 ( )Weight, dry-- kg (lb)251 (553)Performance dataPrime power at 50 Hz (1500 rpm) 19 kW (25 hp)Standby power at 50 Hz (1500 rpm) 21 kW (28 hp)The prime power gen-set Engine rating is the nominal power anengine is capable of delivering with a variable load for anunlimited number of hours per year with normal maintenanceintervals observed. This rating incorporates a 10% overloadcapability which is available for up to 2 hours at a time between 100% and 110% of the prime powerrating is not to exceed 8% of the total Engine operating rating conforms to ISO 8528-1 "prime power (PRP)".

Photographs may show non-standard equipment. PowerTech ™ 4024T Diesel Engine Generator Drive Engine Specifications 4024T shown Certifications Non-Emissions Certified

Tags:

  Engine, John, Diesel, John deere, Deere, Powertech, Powertech 4024t diesel engine, 4024t

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of PowerTech ™ 4024T Diesel Engine - John Deere

1 Photographs may show non-standard equipment. PowerTech 4024T Diesel EngineGenerator Drive Engine Specifications 4024T shownCertifications Non-Emissions CertifiedDimensionsGeneral dataModel4024TF220 Number of cylinders4 Displacement - L (cu in) (146)Bore and Stroke-- mm (in)86 x 105 ( x )Compression :1 Engine TypeIn-line, 4-CycleAspirationTurbochargedLength - mm (in)662 ( )Width - mm (in)566 ( )Height-- mm (in)772 ( )Weight, dry-- kg (lb)251 (553)Performance dataPrime power at 50 Hz (1500 rpm) 19 kW (25 hp)Standby power at 50 Hz (1500 rpm) 21 kW (28 hp)The prime power gen-set Engine rating is the nominal power anengine is capable of delivering with a variable load for anunlimited number of hours per year with normal maintenanceintervals observed. This rating incorporates a 10% overloadcapability which is available for up to 2 hours at a time between 100% and 110% of the prime powerrating is not to exceed 8% of the total Engine operating rating conforms to ISO 8528-1 "prime power (PRP)".

2 Thepermissible average power for the prime or PRP rating is not toexceed 70% of rated prime power when calculated per standby gen-set Engine rating is the nominal Engine poweravailable at varying load factors for up to 200 hours per yearwith normal maintenance intervals observed. No overloadcapability is available for this rating. This rating conforms to ISO8528-1 "Emergency Standby Power (ESP)". The permissibleaverage power for the standby or ESP rating is calculated perISO curveFeatures and benefitsOptimized Gear Train-Front gear train of two high-contact-ratio gears mounted to the block-Impressive low noise characteristicsIndependent Fan Drive-Fan drive operates independently of water pump and is available in twoheights to adapt to enclosures-Fan drive ratios above and below 1.

3 1 are available to match specificapplication requirements-Automatic belt-tensioner and six rib poly-vee drive belt minimizemaintenance and increases belt durabilitHydraulic Valve Lifters-Automatic adjustment eliminates the need for valve-lash adjustment,contributes to lower noise levels in the valve train-Lowers operating costsMultiple-Function Component Integration-Timing gear cover includes water pump housing, oil pump housing, governorhousing and sensors-Rocker arm cover includes intake manifold-Integration results in higher quality, easier service, and reliabilityIndependent Water Pump-Durable cast-iron water pump resists corrosion and pitting for increased wearlifeSmooth Engine Operation-Optional balancer shafts located inside the Engine block with two bearingsper shaft-Decreased vibration reduces operator fatigue and need for instrument andcontrol isolationStarting Aids-Quic k acting glow plugs are standard equipment and provide exceptionalcold weather starting at temperatures as low as -15 degree Fahrenheit-Optional block heater is availableInnovative Fuel Systems-Contributes to cost effectiveness and clean design-Mechanically governed unit pumps mounted inside the block eliminateexternal high-pressure lines.

4 Minimize leak paths and reduce noise level-The electronic controller is standard equipment and provides isochronousgoverning, Engine stop/start and superior generator set performancePerformance data Hz (rpm) Generatorefficiency % Rated fan power Power factor Calculated generator set output kW hp Prime Standby kWe kVA kWe kVA 50 (1500) 88 25 19 18 23 john Deere Power Systems 3801 W. Ridgeway Ave. PO Box 5100 Waterloo, IA 50704-5100 Phone: 1-800-533-6446 Fax: john Deere Power Systems Usine de Saran La Foulonnerie - 45401 Fleury les Aubrais Cedex France Phone: Fax: All values at rated speed and power with standard options unless otherwise noted. Specifications and design subject to change without notice. Litho in (13-12) 2013 john Deere


Related search queries