Example: confidence

PR 1710, PR 1711 Digital weighing transmitter - LESYCO

Benefits Improved process performance Consistent results Higher up-time Lower maintenance costs High FlexibilityDescriptionThe transmitters pr 1710 / pr 1711 areavailable in single Euroformat for 19 racksor in an IP 65 field version. Load cells areconnectable by 6-wire reduce the possibility of EMI, all inputsand outputs are galvanically vibrations of the weighingstructure can be effectively suppressed bymeans of an analogue filter. Additionally,a configurable software filter smoothes thedistortion of the measuring signal whichoccurs under sudden load Digital transmitter has a userfriendly,menu-prompted setup. A separate serial line(RS 232) is accessible via standard SUB-Dconnector and allows calibration andconfiguration by a PC or terminal(VT I00-compatible).

Benefits • Improved process performance • Consistent results • Higher up-time • Lower maintenance costs • High Flexibility Description The transmitters PR 1710/ PR 1711 are

Tags:

  1117, 1107, Pr 1710, Pr 1711, Pr 1710 pr 1711

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of PR 1710, PR 1711 Digital weighing transmitter - LESYCO

1 Benefits Improved process performance Consistent results Higher up-time Lower maintenance costs High FlexibilityDescriptionThe transmitters pr 1710 / pr 1711 areavailable in single Euroformat for 19 racksor in an IP 65 field version. Load cells areconnectable by 6-wire reduce the possibility of EMI, all inputsand outputs are galvanically vibrations of the weighingstructure can be effectively suppressed bymeans of an analogue filter. Additionally,a configurable software filter smoothes thedistortion of the measuring signal whichoccurs under sudden load Digital transmitter has a userfriendly,menu-prompted setup. A separate serial line(RS 232) is accessible via standard SUB-Dconnector and allows calibration andconfiguration by a PC or terminal(VT I00-compatible).

2 These instruments allow calibration withoutweights for fast and easy calibration and configuration parametersare stored in an EEPROM to avoid the loss ofdata in the case of a power ProfileYou are looking for integral processautomation and you want to integrate scalesin your system. These transmitters easilymeet the highest weighing your application requires analogueor Digital signals via bus systems, thesetransmitters cover nearly all needs formodern automation processes. For localprocess control you just choose the pr 1710 / pr 1711 with LCD hazardous area applications we providean intrinsically safe version with load cellconnection with W&M approval for zone 1and one application for zone 2 with W&Mapproval as enable easy linkage to automationsystems, you have the choice betweendifferent serial communication lines such asRS 232 or TTY or RS 485/422.

3 Furthermore,several common bus protocols are 1710, pr 1711 Digital weighing transmitter Accuracy of 3000 e class III (EN 45501) Serial communication interface(RS 232 or TTY or RS 485/422) Option: convenient 5-digit LCD display Configurable analogue output 0/4-20 mA 3 configurable inputs,3 configurable outputs Userfriendly, menu-prompted configuration without separate SW Calibration without weights(Smart Calibration) W&M approval; galvanic isolation of themeasuring signalPR1710 Design: Single EuroformatHeight: 3 HE ( mm)Width without display: 10 TE ( mm)Width with display: 21 TE ( mm)Connector type3*16 pole connector(IEC I30-14, DIN 41612)Standard matching plug: e. g. with soldereyelet from Schroff (69001-712)Supply voltage 18 to 33 VDC, +/- 15 VDC(+/- %)or 24 VAC(+10/-15 %)Power consumption: 7 W, 9 VADisplay (option)Display: 5 digits 7-segment LCDH eight: mmViewing area: x mmDigital inputs 3, optodecoupled, 10 to 31 VDCD igital outputs3 optodecoupled VDC/40 mAPR 1711 Design: Field housingProtection class IP 65 ConnectionVia 6 cable glandsSupply voltage115/230 VAC (+10/-15 %)Power consumption: VAOptional on request:18 to 33 VDC, 24 VAC(+10/-15 %)DisplayDisplay: 5 digits 7-segment LCDH eight: mmViewing area: x mmDigital input3, optodecoupled; 10 bis 31 VDCD igital outputs3, via relays.

4 Contact duty:250 VAC/ 5 A250 VDC/ A100 VDC/ A30 VDC/ A30 VDC/ 5 APR 1710/1711 Configuration/CalibrationVia PC or terminal, VT 100 compatibleService interface9-pole D-SUB connector RS 232, kB for PC or terminal;Functions: calibration, configuration,monitoringCommunication interfaceRS 232, RS 422/485 or current loopselectable with orderMaximum baudrate: kB( kB for CL)ProtocolsEW-Bus, remote display, Modbus/Jbus, DUST3964R, Siemens 3964R-RK512 Analogue output0/4 to 20 mA, max. burden 500 ;configurable for various weights( B, N, T, D)Update rate: proportional to measuring timeResolution: 12 bitAccuracy class3000 e class III (EN 45501, OIML R76)Load cell connectionAll strain gauge load cells;6 or 4 wire connection possibleLoad cell supply12 V or 7 VDC, selectableLoad impedanceMin.

5 ; 6 load cells with 600 each or4 load cells with 350 eachInput signalTotal range: 0 to 36 mV1,2 V/e for W&M applications0,4 V/e for industrial applicationsDead load range:36 mV (max. span) Span and deadloadadjustment via software during calibrationMeasuring principleA/D conversion: integrating converter,ratiometric to LC supplyConversion rate: 50 msMeasuring time: 50 ms; 100 ms or multiplesResolution (internal) V / count;> 75,000 counts for 12 mV> 210,000 counts for 36 mVAnalogue filterActive Butterworth, 40 dB/decade,2 Hz cut-off frequencyLinearity< %Temperature influenceLive zero TKo < 1 V / 10 KSpan Tkspn < 0,006 % /10 KNet weight/shipping weightPR 1710/xx: 0,7 kg / 1,2 kgPR 1711/xx: 4,8 kg / 6,1 kgApprovals and certificatesCEEC type apporval D99-09-002 PTB02 ATEX2058II(2)G[EExib]IIB/CT V 98 ATEX1339 XII3G ExnAIIT4(Zone 2 for 1710)T V 98 ATEX1340 XII3G ExnAIIT4(Zone 2 for 1711)Environmental conditionsVibrationAccording to IEC 68-2-6, Test FcElectrostatic dischargeAccording to IEC 1000-4-2, Level 3 Electromagnetic fieldsAccording to IEC 1000-4-3, Level 226 MHz bis I GhzSupply lineAccording to IEC 1000-4-4, Level 3 Radio interferenceAccording to EN 55011 Temperature rangeOperation: -10 C bis +55 CStorage.

6 -40 C bis +70 CMain screen showing the prompts of the operating level menuTechnical DataDimensions in mmTypical application using a pr 1710 /xxTypical application in a hazardous area using PR 1711with Ex-remote display PR 1628/60 Control of several pr 1710 / pr 1711 transmitters via one PR 1628 remote displayRemote control via ASYMODEM software (up to 16 instruments)PR 1628/60PR 1625/60PR 1711 PLC3 digitaloutputs3 digitalinputsAnalog signal orcommunication linePrinterBusSupervisory SystemRS 485analog-signalCable junction box PR 6130RS 232PC/Terminal3 Digital inputsfor local controlPR 1720 Com-BusPC with Software ASYMODEM telephone extensionPR 1612PR 1720PR 1711PR 1710PR 1711PR 1710RS 485oderTTYPR 1628-60PR 1710with Display3 control outputsHazardous area Ex-Zone 1 Safe areaLimitsPR 1711PR 1710 Sartorius Hamburg GmbHMeiendorfer Stra e 20522145 Hamburg, GermanyTel.

7 + + Euroformat: PR 1710without displayPR 1710/01 (with current loop) pr 1710 /02 (with RS 232) pr 1710 /04 (with RS 422/485) pr 1710 with displayPR 1710/11 (with current loop) pr 1710 /12 (with RS 232) pr 1710 /14 (with RS 422/485)Fieldhousing pr 1711 (Ex) intrinsicallysafe transmitter with displayPR 1711/61 (with Current loop) pr 1711 /62 (with RS 232) pr 1711 /64 (with RS 422/485) pr 1710 (Ex) intrinsically safewithout displayPR 1710/61 (with current loop) pr 1710 /62 (with RS 232) pr 1710 /64 (with RS 422/485) pr 1710 (Ex) intrinsically safewith displayPR 1710/71 (with current loop) pr 1710 /72 (with RS 232) pr 1710 /74 (with RS 422/485)Order numbersSpecifications subject to changewithout in C9498 717 10001 Version informationTypeDescriptionOrder numbers pr 1710 /01 Digital weighing transmitter (TTY)9405 117 10011PR 1710/02 Digital weighing transmitter (RS 232)9405 117 10021PR 1710/04 Digital weighing transmitter (RS 422/485)9405 117 10041PR 1710/11 Digital weighing transmitter with display (TTY)9405 117 10111PR 1710/12 Digital weighing transmitter with display (RS 232)9405 117 10121PR 1710/14 Digital weighing transmitter with display (RS 422/485)9405 117 10141PR 1710/61 Instrinsically safe Digital weighing transmitter (TTY)9405 117 10611PR 1710/62 Instrinsically safe Digital weighing transmitter (RS 232)

8 9405 117 10621PR 1710/64 Instrinsically safe Digital weighing transmitter (RS 422/485)9405 117 10641PR 1710/71 Instrinsically safe Digital weighing transmitter with display (TTY)9405 117 10711PR 1710/72 Instrinsically safe Digital weighing transmitter with display (RS 232)9405 117 10721PR 1710/74 Instrinsically safe Digital weighing transmitter with display (RS 422/485)9405 117 10741PR 1711/61 Instrinsically safe Digital weighing transmitter (TTY)9405 117 11611PR 1711/62 Instrinsically safe Digital weighing transmitter (RS 232)9405 117 11621PR 1711/64 Instrinsically safe Digital weighing transmitter (RS 422/485)9405 117 11641


Related search queries