PRESSURE TEMPERATURE CHART - URI.com

2/13/2018 1:10 PM Page 536. REFRIGERANTS & LUBRICANTS PRESSURE TEMPERATURE CHART . 536 CUSTOMER SERVICE CENTER .. 888-578-9100. 2/13/2018 1:10 PM Page 537. REFRIGERANTS & LUBRICANTS. REFRIGERANTS & LUBRICANTS. Page Refrigerants 538-551. Testing 552-553. Refrigerant Labels 553. Oil 554-560. Lubricant Cross Reference 555-557. TABLE OF CONTENTS 537. 1/26/2018 8:46 AM Page 538. REFRIGERANT PROPERTY SUMMARY. ASHRAE No. Components ASHRAE Safety TEMPERATURE (Trade Name) (Weight %) Rating Glide ( F) Lubricants Comments Very Low TEMPERATURE and Cascade Refrigeration (R-13 and R-503 Type).

General Provisions for Automotive Retrofit Blends: Automotive air conditioning retrofitting is governed by Section 609 of the Clean Air Act. The specific provisions of this section which apply to automotive AC retrofit blends are 1) you can't top off R-12 with a blend, the original charge must be recovered first, 2) new fittings must be ...

Tags:

  Chart, Section, Pressure, Temperatures, Clean, Pressure temperature chart, Section 609 of the clean air act

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of PRESSURE TEMPERATURE CHART - URI.com

1 2/13/2018 1:10 PM Page 536. REFRIGERANTS & LUBRICANTS PRESSURE TEMPERATURE CHART . 536 CUSTOMER SERVICE CENTER .. 888-578-9100. 2/13/2018 1:10 PM Page 537. REFRIGERANTS & LUBRICANTS. REFRIGERANTS & LUBRICANTS. Page Refrigerants 538-551. Testing 552-553. Refrigerant Labels 553. Oil 554-560. Lubricant Cross Reference 555-557. TABLE OF CONTENTS 537. 1/26/2018 8:46 AM Page 538. REFRIGERANT PROPERTY SUMMARY. ASHRAE No. Components ASHRAE Safety TEMPERATURE (Trade Name) (Weight %) Rating Glide ( F) Lubricants Comments Very Low TEMPERATURE and Cascade Refrigeration (R-13 and R-503 Type).

2 R-23 100 A1 0 POLYOLESTER Properties similar to R-13;. runs hotter on discharge side. R-508B 23/116 A1 0 POLYOLESTER Properties similar to R-503;. (46/54) can be used for both types. R-403B 290/22/218 A1 MINERAL OIL or Has been used successfully (5/56/39) ALKYLBENZENE in 13B1 type equipment. Low-Medium TEMPERATURE Refrigeration (R-502 Type). R-22 100 A1 0 MINERAL OIL or Equipment typically uses liquid injection ALKYLBENZENE cooling (high dis. T). R-402A 125/290/22 A1 ALKYLBENZENE Retrofit blend; higher (60/2/38) OR MO/AB MIX discharge PRESSURE than 502.

3 R-402B 125/290/22 A1 ALKYLBENZENE Retrofit blend for ice mach.;. (38/2/60) OR MO/AB MIX higher discharge temp. R-404A 125/143a/134a A1 POLYOLESTER HFC blend - long term new or (44/52/4) retrofit (oil flush required). R-408A 125/143a/22 A1 1 MINERAL OIL or Retrofit blend; slightly (7/46/47) ALKYLBENZENE higher discharge temp. R-422C 125/134a/600a A1 5 MINERAL OIL or HFC blend similar to R422A. (82/15/3) ALKYLBENZENE, POE. R-448A 32/125/1234yf/134a/1234ze A1 7 POLYOLESTER Low GWP alternative to R-404A and R-507.

4 (26/26/20/21/7). REFRIGERANTS & LUBRICANTS. R-452A 32/125/1234yf A1 Low GWP alternative to R-404A and R-507. (11/59/30). R-507 125/143a A1 0 POLYOLESTER HFC blend, azeotrope, (50/50) higher discharge PRESSURE . Low Medium TEMPERATURE Refrigeration (R-22 Type). R-407A 32/125/134a A1 8 POLYOLESTER Similar efficiency and capacity to R-22. (20/40/40). R-407F 32/125/134a A1 10 POLYOLESTER Similar efficiency and capacity to R-22. (30/30/40). R-422D 125/134a/600a A1 5 MINERAL OIL or It can replace R22 with existing oil in system ( ) ALKYLBENZENE, POE.

5 R-290 100 A3 0 MINERAL OIL New equipment only - designed to safely use hydrocarbon refrigerant Low-Medium TEMPERATURE Refrigeration (R-12 Type). R-22 100 A1 0 MINERAL OIL or New systems (retrofit ALKYLBENZENE involves equipment changes). R-134a 100 A1 0 POLYOLESTER HFC - new systems. Retrofit involves oil flushing. R-401A 22/152a/124 A1 8 ALKYLBENZENE Retrofit blend; higher glide (53/13/34) OR MO/AB MIX and discharge PRESSURE /temp. R-401B 22/152a/124 A1 8 ALKYLBENZENE Lower temp. retrofit blend (61/11/28) OR MO/AB MIX (boost to capacity >-20F).

6 R-409A 22/124/142b A1 12 MINERAL OIL or Retrofit blend; higher glide (60/25/15) ALKYLBENZENE and discharge PRESSURE /temp. R-417C 125/134a/600 A1 6 MINERAL OIL or HFC retrofit blend with HC oil additive ( ) ALKYLBENZENE, POE. Medium-High TEMPERATURE Refrigeration (R-12 Type). R-1234yf 100 A2L 0 POLYOLESTER Low GWP; automotive AC and other 134a applications R-1234ze 100 A2L 0 POLYOLESTER Low GWP; chillers and other 134. applications R-414B 22/600a/124/142b A1 12 MINERAL OIL or "Automotive" type blends which can be (50 ) ALKYLBENZENE used for refrigeration.

7 Typically match R-12. in condenser/hot conditions. Loss of capacity occurs at lower evap temps. Air Conditioning (R-22 Type). R-407C 32/125/134a A1 10 POLYOLESTER HFC blend; similar properties (23/25/52) to R-22, higher glide. R-410A 32/125 A1 POLYOLESTER HFC blend; higher pressures, (50/50) new equipment only. R-422B 125/134a/600a A1 5 MINERAL OIL or It can replace R22, R417A and R407C with (55/42/3) ALKYLBENZENE, POE existing oil in system High Ambient and Centrifugal Chillers R-124 100 A1 0 MINERAL OIL or Similar to R-114 - high ambient ALKYLBENZENE air conditioning.

8 R-123 100 B1 0 MINERAL OIL or Similar to R-11 - low ALKYLBENZENE PRESSURE centrifugal chillers 538 CUSTOMER SERVICE CENTER .. 888-578-9100. 1/26/2018 8:46 AM Page 539. REFRIGERANTS. LOW-MEDIUM TEMPERATURE REFRIGERANT (R-12 TYPE). R-401A: A retrofit blend for R-12 refrigeration systems. The PRESSURE R-409A: A retrofit blend for R-12 refrigeration systems. The PRESSURE and system capacity match R-12 when the blend is running in a 10 F and system capacity match R-12 when the blend is running in a 10 F. to 20 F evaporator, and there is typically an 8 F TEMPERATURE glide in to 20 F evaporator, and there is typically 13 F TEMPERATURE glide in the the evaporator.

9 Applications: direct expansion refrigeration and air evaporator. Applications: direct expansion refrigeration and air conditioning systems designed for R-12 or R-500; good success in any conditioning systems designed for R-12 or R-500; good success in any size system, minor adjustment of controls needed. Discharge PRESSURE size system, minor adjustment of controls needed. Discharge PRESSURE increases compared to R-12, also slight increase in discharge and TEMPERATURE increases compared to R-12, which may be a problem TEMPERATURE , however the increases are not as severe as some other in very hot ambient conditions.

10 Capacity holds well into lower retrofit blends. There is a drop in capacity at lower temperatures . R- application temperatures (-30 F). R-409A mixes well with mineral oil 152a content, an HFC, hurts the miscibility with mineral oil. It is down to 0 F. As a result it may not be necessary to change oil in recommended to change some of the oil to alkylbenzene unless the systems which do not run colder than 0 F in the evaporator (below 0 F. system is small and running at higher evaporator temperatures . alkylbenzene should replace some mineral oil).