Primary lithium battery LS 14250 - descargas.cetronic.es

Primary lithium battery LS 14250 . V Primary lithium -thionyl chloride (Li-SOCl2). High energy density 1. 2 AA-size bobbin cell Benefits Cell size references R6 AA. l . High voltage response, stable during most of the lifetime of Electrical characteristics the application (typical values relative to cells stored for one year or less at + 30 C max.). l . Wide operating temperature Nominal capacity Ah range (- 60 C/+ 85 C). (at 1 mA + 20 C V cut-off. The capacity restored by the cell varies l . Low self-discharge rate according to current drain, temperature and cut-off). (less than 1 % per year of Open circuit voltage (at + 20 C) V. storage at + 20 C). Nominal voltage (at mA + 20 C) V. l . Easy integration into compact systems Nominal energy Wh l.

Primary lithium battery LS 14250 3.6 V Primary lithium-thionyl chloride (Li-SOCl 2) High energy density 1⁄ 2 AA-size bobbin cell September 2009 Benefits l High voltage response, stable during most of …

Tags:

  Primary, Battery, Lithium, 14025, Primary lithium battery ls 14250

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Primary lithium battery LS 14250 - descargas.cetronic.es

1 Primary lithium battery LS 14250 . V Primary lithium -thionyl chloride (Li-SOCl2). High energy density 1. 2 AA-size bobbin cell Benefits Cell size references R6 AA. l . High voltage response, stable during most of the lifetime of Electrical characteristics the application (typical values relative to cells stored for one year or less at + 30 C max.). l . Wide operating temperature Nominal capacity Ah range (- 60 C/+ 85 C). (at 1 mA + 20 C V cut-off. The capacity restored by the cell varies l . Low self-discharge rate according to current drain, temperature and cut-off). (less than 1 % per year of Open circuit voltage (at + 20 C) V. storage at + 20 C). Nominal voltage (at mA + 20 C) V. l . Easy integration into compact systems Nominal energy Wh l.

2 Superior resistance to Pulse capability: Typically up to 100 mA. atmospheric corrosion (100 second pulses, drained every 2 mn at + 20 C from undischarged cells with 10 A base current, yield voltage readings above Key features V. The readings may vary according to the pulse characteristics, the temperature, and the cell's previous history. Fitting the cell with a capacitor l . Stainless steel container may be recommended in severe conditions. Consult Saft). and end caps Maximum recommended continuous current 35 mA. (low magnetic signature) (Higher currents are possible, consult Saft). l Hermetic glass-to-metal sealing Storage (recommended) + 30 C (+ 86 F) max l Non-flammable electrolyte (for more severe conditions, consult Saft).

3 L Compliant with IEC 60086-4. Operating temperature range - 60 C/+ 85 C. safety standard and (Operation above ambient T may lead to reduced capacity and (- 76 F/+ 185 F). IEC 60079-11 intrinsic safety lower voltage readings at the beginning of pulses. Consult Saft). standard (class T4 assignment). Physical characteristics l Underwriters Laboratories (UL). Component Recognition Diameter (max) mm ( in). l Non-restricted for transport/ Height (max) mm ( in). Non-assigned to Class 9 Typical weight g ( oz). according to the UN. Li metal content approx. g Recommendations on the Available termination suffix transport of dangerous goods CN, CNR radial tabs Model Regulations 2 PF, 3 PF, 3 PF RP, 4 PF radial pins l Manufactured in France, UK, China CNA (AX) axial leads FL flying Main applications l Utilitymetering l Automatic meter reading l Alarms and security devices l Tollgate systems l Memory back-up l Computer real-time clocks l Tracking systems l Automotive electronics l Professional electronics September 2009.

4 LS 14250 Voltage plateau versus Current and Temperature (at mid-discharge). + 70 C. + 20 C. Cell voltage (V). - 20 C. - 40 C. min max (flat area). 1 10 100. Current (mA).. Typical discharge profiles at + 20 C. Cell voltage (V). (flat area) Dimensions in mm. mA. 400 mA. 3 mA. 56 Ohms/54 mA. 1 10 100 1000 10000. Time (hours). Storage Restored Capacity versus Current and Temperature ( V cut-off). l . The storage area should be 1300. clean, cool (preferably not 1200. 1100 + 20 C. exceeding + 30 C), dry and 1000. ventilated. + 70 C. Capacity (mAh). 900. 800. - 20 C. Warning 700. 600. l . Fire, explosion and burn hazard. 500. l . Do not recharge, short circuit, 400 - 40 C. crush, disassemble, heat above 300. 200. 100 C (212 F), incinerate, 100.

5 Or expose contents to water. 0. l . Do not solder directly to the cell 1 10 100. (use tabbed cell versions instead). Current (mA). Doc. No 31072-2-0909. Information in this document is subject to change without notice and becomes contractual only after written confirmation by Saft. For more details on Primary lithium technologies please refer to Primary lithium Batteries Selector Guide Doc No 31048-2. Published by the Communications Department. Telephone: +44 (0)191 496 9999 Photo credit: Saft Email: Soci t anonyme au capital de 31 944 000. RCS Bobigny B 383 703 873. Website: Produced by Arthur Associates Limited.