Primeline CatalogPeClFor over 70 years, Fireye has manufactured quality combustion control products for the commercial and industrial markets. With more than a million installations throughout the world, we are proud of our global reputation and worldwide market position. Dedicated to a constant process of innovation and service, we consistently provide safe and reliable products to our customers. FLAME SAFEGUARD CONTROLSP rimeline Products Fireye, Inc. 2011 The names FIREYE, MicroM, SIGNATURE SCANNER, FIRETRON and FLAME-MONITOR are registered trademarksof Fireye, in this catalog are not necessarily shown to additional information visit our web site at : When Fireye products are combined with equipment manufactured by others and/or integrated intosystems designed or manufactured by others, the Fireye warranty, as stated in its General Terms and Conditions ofSale, pertain only to the Fireye products and not to any other equipment or to the combined system or its , Fireye receives inquiries from the field concerning the use of rebuiltcontrols.

The Flame-Monitor Series provides the proper burner sequencing, ignition and flame monitoring protection on automatically ignited oil, gas and combination fuel burners.

Tags:

  Series, Burner, Primeline

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Primeline CatalogPe C l - AC Controls

1 Primeline CatalogPeClFor over 70 years, Fireye has manufactured quality combustion control products for the commercial and industrial markets. With more than a million installations throughout the world, we are proud of our global reputation and worldwide market position. Dedicated to a constant process of innovation and service, we consistently provide safe and reliable products to our customers. FLAME SAFEGUARD CONTROLSP rimeline Products Fireye, Inc. 2011 The names FIREYE, MicroM, SIGNATURE SCANNER, FIRETRON and FLAME-MONITOR are registered trademarksof Fireye, in this catalog are not necessarily shown to additional information visit our web site at : When Fireye products are combined with equipment manufactured by others and/or integrated intosystems designed or manufactured by others, the Fireye warranty, as stated in its General Terms and Conditions ofSale, pertain only to the Fireye products and not to any other equipment or to the combined system or its , Fireye receives inquiries from the field concerning the use of rebuiltcontrols.

2 In years past, Fireye and other manufacturers of flame safety devices did rebuilt Controls were certified by a nationally recognized testing agency (UL)and subject to different standards than new equipment. Essentially, all components werereplaced with the exact components that were used in a new control. Only the housingsand lenses (if applicable) were reused. Fireye no longer rebuilds Controls (as of 1989), norhave we authorized any other company to rebuild for , there are several other companies selling rebuilt or reconditioned con-trols. None of these companies has an approval from any nationally recognized testingagency. What this means is the Fireye assumes no liability for any incident resulting from the use of a rebuilt Your insurance coverage should be reviewed if you use rebuilt The use of safety Controls rebuilt by any party other than the original manufacturer is in violation of ASME, CSD-1 Use of rebuilt Controls is in violation of National Fire Protection Agency over seventy years, Fireye has been a leader in promoting flame safety.

3 We arevery committed to adhering to standards established by testing agencies, fire codes andinsurance requirements as well as developing new scanner : NOTICE4 FIREYE Primeline PRODUCTSPART NUMBERPAGE4-263-1454-314-14510-884514-64 8, 2623-1763523-1833535-694535-127-14535-12 7-34538-964538-974545UV3-1050 4445UV5-10054445UV5-10064445UV5-10074445 UV5-1007 CEX4445UV5-10084745UV5-10094445UV5-1009 CEX4445UV5-1009EX4445UV5-11054446-384546 -564548-18058, 8, 4548-18368, 8, 4548PT2-10034448PT2-10074448PT2-90034448 PT2-90074448PT2-9007W4448PT2-CEX 4457AV7-10003557YB4-50001559-504-0104159 -509-101959-509-151959-509-201959-509-25 1960-3024560-8014560-11994660-12574660-1 2904660-1386-28, 26, 860-1466-28, 26, 860-1664-34660-1664-44660-195013, 1360-25383760-2539-1237, 3760-2539-2437, 4060-2539-3637.

4 4060-27264060-2810-11560-2812-11560-2814 -11560-2850-11760-2852-11760-2854-11760- 2872-11860-2874-11861-2914-14661-4364661 -2914-15061-306033, 3561-32634661-5042 33, 3561-5745-315, 17, 4665UV5-10043865UV5-1004E3865UV5-1004 ECEX3869ND1-1000K441, 4469ND1-1000K641, 4469ND1-1000K841, 4470D1029 PART NUMBERPAGE70D202970D212970D302970D402970 D412971D602971D612971D702971D802971D8129 71D902972D1R12972D1R1T2972D1R32972D1R3T2 972 DRT12972 DRT1T2972 DUV12972 DUVS1T2972 DUVS42982-9546129-145-19129-145-29129-14 5-39129-168-138129-168-238129-17240129-1 78-415, 17129-178-815, 17 BLD50015, 17 BLL51015, 17 BLV51215, 17E1R1 12, 27E1R212E1R312, 12E1008E1108E1208 PART NUMBERPAGEPART NUMBER INDEXFIREYE Primeline PRODUCTS 5E210 26E21126E300 13E320 28E340 24E34324E34424E34524E350-313, 13E350-613, 13E720W-CD24, 25EB34224EB7008EB72026EB72126EC48513, 13, 25, 13EC6008 EDC112 EDC212ED5109, 9ED512-213, 18, 13ED512-4 18ED512-8 18ED580-19, 15,17ED580-29ED580-49, 18ED580-89, 18ED6109, 19, 25EP100F10EP100S10EP113D27EP113E27EP113E S27EP113F27EP113NL27EP113NR27EP113SW27EP 16010EP16110 PART NUMBERPAGEEP16310EP16510EP16610EP17010EP 17410EP17710EP17810EP200F10EP200S10EP260 10EP26510EP27010EP300F10EP300S10EP34024E P37810EP38010EP38110EP38210EP39010 EPD16011 EPD16111 EPD17011 EPD26011 EPD26111 EPD27011 EPD38011 EPD38111 EPD38211 EPD39011 ERT112, 12 EUV112, 12 EUVS412, 12IT100015, 17.

5 19 MART1 35 MART1T 35 MART335 MAUV1 35 MAUV1T 35 PART NUMBERPAGEMAUV335MB-600PF39, 40MB-600S39MB-604E39MB-608E39MB-632S39MB -685S39 MBB-300D37 MBHPS-100D37 MBHPS-200D37 MBLPS-100D37 MBLPS-200D37 MBPF-100S40 MBPF-200S40 MBPF-202S40 MBUV-300D37 MBUV-310D37 MBUVS-301D37 MBUVS-311D37MC120 35MC120E35MC120P35MC120R35MC120RE35MC230 35MC230R35 MEC12031 MEC120C31 MEC120D31 MEC120R31 MEC120RC31 MEC120RD31 MEC23031 MEC230RC31 MEC32032 MEC320C32 MEC320D32 MEC320R32 MEC320RC32 PART NUMBERPAGE6 FIREYE Primeline PRODUCTSMEC320RD32 MEC320TS32 MEC48032 MECD133 MECD433 MED133 MED233 MED333 MED433 MED533 MED633 MED733 MEDC233 MEIR132 MEIR432 MEP10032 MEP10132 MEP10232 MEP10332 MEP10432 MEP10532 MEP10632 MEP10732 MEP10832 MEP10932 MEP13032 MEP14132 MEP14932 MEP100P32 MEP23032 MEP230H32 MEP23532 MEP23632 MEP23733 MEP23832 MEP29032 MEP30033

6 MEP30433 MEP39733 PART NUMBERPAGEMEP43732 MEP53632 MEP53732 MEP56032 MEP56132 MEP56232 MEP56432 MEP69633 MEP69733 MERT132 MERT432 MEUV133 MEUV433 MEUVS133 MEUVS433MP10035MP100E35MP10135MP10235MP1 02E35MP230 35MP230H 35MP560 35MP56135MP56235N018032-1019N018040-KIT1 9N200233-0019N250339-0019 NXAM21 NXC0420 NXC1220 NXC2021 NXC4021 NXDBMB21 NXDBVSD21 NXIATS21 NXO2 INT21 NXO2PK421 PART NUMBERPAGENXO2PK621 NXO2PK821 NXTSD10420NX60023NX61023NX1030-121NX1030 -221NX1034-121NX1034-221NX1040-121NX1044 -121NX610020NX611020 PPC600015, 17, 15PS348-124PS348-224PS348-324PS348-424PS 348-524PS348-624PS348-724PS348-824 PXMS-1521 PXMS-20021 PXMS-30021TS348-224TS348-424TS348-824TS3 50-221TS350-421TS350-821TS752-221TS752-4 21TS752-821UC48513, 18, 25UV1A-1-CEX44UV1A3 44UV1A6 44UV1A50 44 PART NUMBERPAGEFIREYE Primeline PRODUCTS 7UV2 44UV7A441UV7A4W41UV7R441UV7SC41UV8A44UV9 0-3 44UV90-6 44UV90-9 44YB110DC15YB110FR15YB110IR15YB110IR215Y B230DC15YB230FR15YB230IR15YB230UV15YB230 UVSC15YP10015, 17YP10215, 17YP11315, 17YP11815, 17YP13815, 17YP20015YP20215YP30015YP30215YZ30018YZ3 00P18YZ23018ZB110IR17ZB110IR217ZB110UV17 ZB110 UVSC17ZB230IR17ZB230UV17ZB230 UVSC17 PART NUMBERPAGE8 FIREYE Primeline PRODUCTSFLAME-MONITOR CONTROLB ulletin E-1101 The Flame-Monitor series provides the proper burner sequencing, ignition andflame monitoring protection on automatically ignited oil, gas and combination fuelburners.

7 On a safety shutdown, the display module will advise the operator that thecontrol is in Lockout and indicate the cause as well as the position in the operat-ing sequence that it occurred. Interchangeable programmer and flame amplifier modules allow complete versa-tility in selecting control function. The Flame-Monitor control uses the same wiringbase as the Fireye D- series and C- series Controls and is directly interchangeablewith most models without rewiring. The Flame-Monitor control can be used with ultraviolet, AUTOCHECK infrared,photocell, flame rod or self-check ultraviolet flame scanners by choosing the properamplifier module. Special features include: remote reset, remote display, expandedannunciation of safety lockouts, programmability of safety interlock messages, andremote data communications capability.

8 A 220 volt version of the E110 control isalso available without any agency approvals. (P/N E120).The complete FLAME-MONITOR control consists of:DIMENSIONSPart NumberDescriptionE100 OBSOLETE - Replace with E110. Display unit consisting of one each EB700, 48-1836, and EC600. Display ordered separately. unit, consisting of one each EB701, 48-1836, and EC600. 220 VAC operation. No agency chassis only for E110 and dust cover for E110 and screw for E100, E200, E201,E34048-1836 Mounting screw for E110, E120, E210, E21160-1386-2 Wiring Base - Surface Mount60-1466-2 Wiring Base - Cabinet Mount14-64 Noise line filter for E100/E110 E110 Chassis ED510 Display Module EP Programmer or EPD Programmers(EPD programmers do not require ED510 display) Amplifier Scanner Wiring Base7 9/32(185)6(152)1 7/8(48)5 3/4(146)1/2 KNOCKOUTCONTROL WITH COVERAND WIRING BASE4 7/8( )5 11/16( )2 7/16( )5 1/4(133)7( )11/16( )3/4( )25/32( )1/4 TYP( )390 TYP( )KNOCKOUTS FOR1/2 CONDUIT (7)1 1/16(27)1 3/16( )WIRING BASEMOUNTING HOLES3 5/8 (92)

9 FIREYE Primeline PRODUCTS 9ED510 Display ModuleBulletin ED-5101 The ED510 Display Module is designed to operate with the Flame-MonitorBurner Management Control System using the EP and EPD style The ED510 display is optional for EPD programmers, but isrequired for the EP style ED510 display module provides the following features and capabilities LCD backlit display with two (2) lines of sixteen (16) characters each. Continuous display of current burner operating status, including first outannunciation in the event of a lockout condition. Three (3) key, tactile dome keypad provides historical information of theburner, last six (6) lockout conditions (with burner cycle and burner hourtime stamp), assign messages associated with the operation of the E300expansion module, and diagnostic messages.

10 Design which mounts directly onto the front face of the EP style program-mers. RJ style connector for connection to the EP and EPD style Remote display capability with the EP and EPD style programmers usingstandard DIN sized opening and remote mounting kit. DIMENSIONS TO REMOTE MOUNT ED510 EP programmers must have an Eng. code of 28 or higher, the EPD programmers must have an Eng. code of 02 or NumberDescriptionED5102 line x 16 character LCD display with Display cable with RJ45 connector 1 1/4 inchED580-2ED510 Remote display cable with RJ45 connector 2 feetED580-4ED510 Remote display cable with RJ45 connector 4 feetED580-8ED510 Remote display cable with RJ45 connector 8 feet129-145-1 Remote display (ED510) mounting kit with 4 ft.