Example: dental hygienist

Product 30RAP010-150 (60 Hz) AquaSnap Data 30RAP070 …

AquaSnap . Product 30 RAP010-150 (60 Hz). Data 30 RAP070-150 (50 Hz). Air-Cooled Chillers with Puron Refrigerant (R-410A). 10 to 150 Nominal Tons (60Hz). (35 to 528 Nominal kW). 70 to 150 Nominal Tons (50Hz). (246 to 528 Nominal kW). The AquaSnap chiller is an effective all- a30-4827 in-one package that is easy to install and easy to own. AquaSnap chillers operate quietly and efficiently. Value-added features include: Rotary scroll compression HFC Puron refrigerant (R-410A). Low-sound AeroAcoustic fan system Easy to use ComfortLink controls Optional integrated hydronic pump package (60 Hz only) with VFD. (variable frequency drive) compatible motors, with optional VFD on size 070- a30-4826 150 models Coil design flexibility Microchannel coil technology available on all units, and RTPF coil technology available on sizes 070-150.

compact, all-in-one package design that installs quickly and easily on the ground or the rooftop. The optional pump and hydronic components (60 Hz only) are already built in; this costs less than buy-ing and installing the components indi-vidually. The chiller’s fully integrated and pre-assembled hydronic system (60 Hz only) installs in minutes.

Tags:

  Rooftop, Packages

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Product 30RAP010-150 (60 Hz) AquaSnap Data 30RAP070 …

1 AquaSnap . Product 30 RAP010-150 (60 Hz). Data 30 RAP070-150 (50 Hz). Air-Cooled Chillers with Puron Refrigerant (R-410A). 10 to 150 Nominal Tons (60Hz). (35 to 528 Nominal kW). 70 to 150 Nominal Tons (50Hz). (246 to 528 Nominal kW). The AquaSnap chiller is an effective all- a30-4827 in-one package that is easy to install and easy to own. AquaSnap chillers operate quietly and efficiently. Value-added features include: Rotary scroll compression HFC Puron refrigerant (R-410A). Low-sound AeroAcoustic fan system Easy to use ComfortLink controls Optional integrated hydronic pump package (60 Hz only) with VFD. (variable frequency drive) compatible motors, with optional VFD on size 070- a30-4826 150 models Coil design flexibility Microchannel coil technology available on all units, and RTPF coil technology available on sizes 070-150.

2 Accessory fluid storage tank on size 010-060 models Optional digital scroll compressors on size 010-090 models Features/Benefits Carrier's superior chiller design provides savings at initial purchase, at installa- tion, and for years afterward. Costs less right from the start Carrier's AquaSnap chillers feature a compact, all-in-one package design that installs quickly and easily on the ground or the rooftop . The optional pump and hydronic components (60 Hz only) are already built in; this costs less than buy- a30-5347. ing and installing the components indi- vidually. The chiller's fully integrated and pre-assembled hydronic system (60 Hz only) installs in minutes. No other chiller in this class installs so easily and inex- pensively. The preassembled and inte- grated hydronic module utilizes top-qual- ity components and pumps to ensure years of reliable operation.

3 Carrier Corporation 2014 Form 30 RAP-11PD. Features/Benefits (cont). Use of the optional fluid storage tank, circuit for greater efficiency at partial Single/dual pumps up to 15 hp available on size 010-060 models, re- loads. and 160 ft head duces installation costs and ensures suf- Electronic expansion valve (EXV) Strainer ficient fluid volume is available for allows for precise control through all Flow regulator close-coupled and process cooling ap- operating ranges, resulting in higher Freeze protection to 20 F ( 29 C). plications. The AquaSnap unit's high efficiency and improved reliability. (with freeze protection option). efficiency keeps costs down. Heaters Proven reliability that's built in Required piping AquaSnap chillers make Thousands of AquaSnap chillers are Pressure/temperature taps noise in the marketplace, not already in service around the world.

4 Isolation valves for dual pump the workplace. This field-proven design is backed by a systems The AquaSnap chiller's low-sound 12-month warranty that includes the VFD available on sizes 070 to 150, AeroAcoustic fan produces up to half hydronic system. The compressors are and VFD compatibility on all models the sound level of propeller fans. Much maintenance-free and protected by an The factory-installed and tested hy- of the noise reduction is in frequencies auto-adaptive control that minimizes dronics package provides faster, sim- where noise is most annoying, which compressor wear. Unit sizes 035 and pler and less expensive installation. makes AquaSnap chillers ideal for up have two independent refrigerant sound-sensitive environments. When Digital scroll compressors are circuits. Year-round operation is lower ambient temperatures allow part available as a factory-installed option standard, from 20 F ( 29 C) (with op- on sizes 010 to 090.)

5 These allow for load operation or during scheduled tional cooler heater, low ambient con- nighttime operation, the units operate incremental unloading with capacity trol, and wind baffles) to 120 F (50 C). with fewer fans and become even qui- modulation to better match building Rotary scroll compressors provide load when compared to standard scroll eter. AquaSnap chillers are quiet dur- smooth, quiet and reliable operation. compressors. ing the day and even quieter at night. The savings will continue to All-in-one package Environmentally balanced mount AquaSnap chillers provide the most Carrier's Puron refrigerant (R-410A). comprehensive chilled water circuit enables you to make a responsible de- Besides costing less to buy and install, available for any air-cooled chiller. cision in the protection of the earth's AquaSnap chillers are also more af- Included is a brazed plate direct fordable to operate.

6 Carrier's Aqua ozone layer. Puron refrigerant is a expansion cooler that may be remote- HFC refrigerant that does not contain Series chillers are our most efficient mounted. The cooler is also completely air-cooled models. The AquaSnap chlorine that is damaging to the ozone drainable with factory-installed vents layer. Puron refrigerant is unaffected chiller provides full load EER (Energy and drains. by the Montreal Protocol. Puron refrig- Efficiency Ratio) up to and IPLV. (integrated part load value) up to Electronic thermal-dispersion erant is a safe, non-toxic*, efficient and for 60 Hz applications, and full load flow switch is included with the cool- environmentally balanced refrigerant EER up to and IPLV up to er. The switch is factory installed and for the future. for 50 Hz applications. AquaSnap tested and contains no moving parts for high reliability.

7 Durable construction chillers use ultra-quiet, high-efficiency The 30 RAP chillers have a structurally rotary scroll compressors, operated in Optional integrated hydronics sound base that can be point-loaded, single (sizes 010 and 015) tandem (siz- package (60 Hz chillers only) is more therefore, no perimeter base rail is re- es 018 to 060), and tandem or trio than just a pump, it is an entire chilled quired. All 30 RAP units have weather- (sizes 070 to 150) per independent water system, including: ized cabinets constructed of heavy-duty galvanized steel with exterior panels painted with corrosion-resistant baked Table of contents Page enamel. Inside and outside surfaces are protected to ensure long life and good Features/Benefits .. 1-3 appearance. The durable, galvanized Model Number Nomenclature.. 4 steel, painted components exceed the AHRI Capacity Ratings.

8 5 requirements of the 500-hour salt Physical Data .. 6-13 spray test per ASTM (American Soci- Options and Accessories .. 14-16 ety for Testing and Materials) B117. Base Unit Dimensions .. 17-22 ComfortLink controls speak Accessory Dimensions .. 23-25 your language Selection Procedure .. 26. Performance Data .. 27-55 The ComfortLink controls communi- Typical Piping and Wiring .. 56-59 cate in plain English, making it as easy Electrical Data .. 60-77 as possible to monitor and control Controls.. 78-80 each AquaSnap chiller while accurately Typical Control Wiring Schematic.. 81 maintaining fluid temperatures. The Application Data.. 82-89 large scrolling marquee display acts as Guide Specifications .. 90-96 a window into the unit's operation, * Under ASHRAE Standard 34-1992, R-410A. 2 is classified as an A1 refrigerant.

9 Providing easy-to-read information A BACnet* communication option is recommended for particular applica- about chiller performance and over also available for the i-Vu Open con- tions in coastal/marine environments. 15 diagnostic functions. Carrier's trol system or a BACnet building auto- Following the input of the requested 30 Series chillers' ComfortLink mation system. data, the E-Cat program output will ad- controls provide features such as vise the appropriate coil to be used. chilled water temperature reset, de- AquaSnap units minimize the Other factors described in Selection mand limiting, compressor wear mini- impact on your footprint, as Guide: Environmental Corrosion mization and protection, temperature well as your bottom line Protection catalog number and pressure displays and diagnostic The integrated hydronics and the 04-581061-01 must also be functions.

10 These controls result in chilled fluid storage tank's placement considered to determine if corrosion higher chiller reliability, simplified under the chiller minimize the foot- protection is required. training and more productive service print, allowing easy installation almost Microchannel coils are more robust calls with correspondingly lower opera- anywhere. than other coil types, making them tional and maintenance costs. Novation heat exchanger easier to clean without causing damage Carrier's exclusive accessory hand- technology to the coil. held Navigator display provides con- The Novation heat exchanger design Due to the compact all aluminum venience and powerful information in with microchannel (MCHX) condenser design, microchannel coils will reduce the palm of your hand. The Navigator coil is a robust, cost effective alterna- average unit operating weight by 25%.