Example: air traffic controller

Product Bulletin 1061 Actuator August 2017 Fisher …

1061 pneumatic piston RotaryActuatorFisher 1061 pneumatic piston rotary actuators areused to operate splined shaft rotary control valvessuch as Vee Ball valves, eccentric disk valves, andbutterfly valves. The Actuator /valve body linkage ofthis Actuator can be positioned for eitherpush down to open or push down to close , the 1061 Actuator can be used with atwo position control signal for on off service or with avalve positioner for throttling service. An optionalhandwheel Actuator is also available to allow forauxiliary or emergency manual valve operation whenthe 1061 piston Actuator is not in use. For completeinformation on the valve positioner and the manualhandwheel Actuator , refer to the appropriate Application Flexibility Actuator is available inpush down to open or push down to closeconstruction and may be mounted in any of fouractuator/valve body mounting positions (see figure2).

www.Fisher.com Fisher™ 1061 Pneumatic Piston Rotary Actuator Fisher 1061 pneumatic piston rotary actuators are used to operate splined‐shaft rotary control valves such as Vee‐Ball™ valves, eccentric disk valves, and

Tags:

  Piston, Rotary, Pneumatic, Actuator, 6110, 1061 pneumatic piston rotary actuator

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Product Bulletin 1061 Actuator August 2017 Fisher …

1 1061 pneumatic piston RotaryActuatorFisher 1061 pneumatic piston rotary actuators areused to operate splined shaft rotary control valvessuch as Vee Ball valves, eccentric disk valves, andbutterfly valves. The Actuator /valve body linkage ofthis Actuator can be positioned for eitherpush down to open or push down to close , the 1061 Actuator can be used with atwo position control signal for on off service or with avalve positioner for throttling service. An optionalhandwheel Actuator is also available to allow forauxiliary or emergency manual valve operation whenthe 1061 piston Actuator is not in use. For completeinformation on the valve positioner and the manualhandwheel Actuator , refer to the appropriate Application Flexibility Actuator is available inpush down to open or push down to closeconstruction and may be mounted in any of fouractuator/valve body mounting positions (see figure2).

2 N Minimal Dead Band Single point linkage withsplined and clamped lever minimizes lost motionand improves control Compact Construction Compared to similaractuators, overall size is reduced by as much as Actuator with FIELDVUE DVC6200 Digital ValveController Mounted on a Fisher V500 ValveW8380-2n Long Service Life Rugged construction providesstability, corrosion resistance, and protection fromdeformation should the Actuator be over Accessibility Actuator /valve body linkage iscompletely enclosed, yet the valve packingadjustment remains accessible without removingany Monitoring Ease Highly visible travel indicatorallows easy determination of valve ActuatorD100095X012 Product :1061 August 20171061 ActuatorD100095X012 Product :1061 August 2017 2 SpecificationsAvailable ConfigurationActuator Sizes: J30, J40, J60, J68, J80,J100, and J130 Action: Double acting pneumatic piston rotaryactuator for Jthrottling service when used withpositioner, or Jon off service when used withswitching devicesCylinder Operating PressureMinimum Recommended: bar (20 psig)without positioner, or bar (5 psi) aboveactuator requirement with positioner(1).

3 Maximum Allowable(2)Sizes 30 and 60: bar (100 psig)Size 40: bar (150 psig)Size 68: bar (85 psig)Size 80: bar (150 psig)Size 100: bar (150 psig)Size 130: bar (150 psig)Valve Shaft Diameters, mm (Inch)Size 30: (1/2), (5/8), (3/4), (7/8), (1), and (1 1/4)Sizes 40, 60, and 68: (3/4), (7/8), (1), (1 1/4), (1 1/2), (1 3/4), and (2)Sizes 80 and 100: (1 3/4), (2), (2 1/2)Size 130: (3) and (3 1/2)Maximum Valve Shaft RotationJ90 degrees without travel stop or J60 degreeswith optional travel stopMaximum Breakout Torque(1)Size 30: Up to 282 NSm (2500 lbfSin)Size 40: Up to 847 NSm (7500 lbfSin)Size 60: Up to 1130 NSm (10,000 lbfSin)Size 68: Up to 1540 NSm (13,600 lbfSin)Size 80: Up to 5080 NSm (45,000 lbfSin)Size 100: Up to 6290 NSm (55,700 lbfSin) with (2 1/2 in.)

4 Valve shaft diameterSize 130: Up to 19,800 NSm (175,000 lbfSin)Stroking TimeDependent on Actuator size, rotation, and positionerif used. If stroking time is critical, consult yourEmerson sales office or Local Business PartnerConstruction MaterialsCylinder and Cylinder Flange: AluminumHousing Cover: JCast iron or Jaluminum (only forsize 130) piston : JAluminum or JNylon coated piston (optional only for sizes 30 to 100) piston Rod: Chrome plated stainless steelLever: Ductile ironSliding Seal: AluminumO Rings: NitrileHousing:Sizes 30, 40, 60, and 68: Cast ironSizes 80, 100 and 130: AluminumMounting Yoke: Cast ironMounting Yoke Bushing: PTFE and steelMaterial Temperature Capabilities with StandardElastomers(2)-34 to 82_C (-30 to 180_F)Pressure ConnectionsJ 1/4 NPT internal (standard)J 1/2 and 3/4 NPT internal (optional on sizes 68, 80,and 100)J 3/4 NPT internal for Pipe-Away Vent optionJ 1 NPT internal for size 130 Travel IndicationGraduated scale and pointer located on Actuator endof valve shaftMounting PositionsSee figure 2 Approximate WeightSee table 21.

5 Actual Actuator torque available depends on specific construction and casing pressure. For information on torque requirements of the valve being considered, contact your Emerson The pressure/temperature limits in this manual and any applicable standard or code limitation for Actuator should not be ActuatorD100095X012 Product :1061 August 2017 3 Figure 1. Sectional of Fisher 1061 ActuatorW3827 1W2288 3 Table 1. Displacement for 90 Degree RotationSIZEPISTON DOWNPISTON UPcm3 Inch3cm3 Inch33040606880100130110021304060721013, 00019,10041,1006713024844079411652508120 022304380711012,90018,80040,200741362674 3478811502454 Table 2. Approximate WeightACTUATOR SIZEkgLb30406068801001302229395612213529 9496386123246298660 OptionsPneumatic Instruments: J3710, J3610JP, orJ3620JP pneumatic or electro pneumatic positionersor JFIELDVUE DVC6200 Digital Valve Controllers areavailable.

6 Also, the 377 Series trip valves are availablewith Jlock in last position, Jfail up, or Jfail downaction (for specifications, see separate bulletins).Potentiometer: It is used for remote valve Bypass: The bypass valve is required when ahandwheel Actuator is Switches: JTopWorx DXP M21 GNEB limitswitch for one through six single pole, double throwcontacts (see separate Bulletin ), JGO Switch proximity switches for one or two single pole,double throw contacts, or JMicro Switches orNAMCO switches for one or two single pole,double throw or double pole, double throw Switch proximity switch is not available for size 80,100 or 130 Actuator : The Fisher 1078 manualdeclutchable Actuator (see figure 3) allows auxiliary oremergency valve operation of sizes 30 through 100when engaged see Fisher Bulletin :1078(D101339X012).

7 Locking Mechanism: The locking mechanism shown infigure 4 is available for sizes J30, J40, J60, andJ68 actuators. The locking mechanism shown infigure 5 is available for sizes J80 and Connections: Optional quickdisconnect connections are available for use with theportable FlowScanner microprocessor baseddiagnostic testing Away Vent: Some applications use natural gas orother hazardous gases as a supply pressure to theactuator. These applications require the actuatorhousing to be vented, reducing the accumulation ofgases. For new constructions and retrofit kitinformation, contact your Emerson sales office or LocalBusiness Partner with complete service ActuatorD100095X012 Product :1061 August 2017 4 Table 3.

8 Mounting Styles and PositionsMOUNTINGACTION(1)VALVE SERIES OR DESIGNVALVE SERIES OR DESIGNBALL/PLUGROTATION TOCLOSEV250V150, V200 andV300CV500 andV500 DISK/BALLROTATION TOCLOSEV2508510B, 8532,8560and 9500 Right HandPDTCPDTOCCWCCWABABABCWCWNANABALeft HandPDTCPDTOCCWCCWNANADCDCCWCWCDCDLeft Hand(Optional)(2)PDTCPDTOCWCWNANACDNANAN ANANANANANA1. PDTC Push down to close, and PDTO Push down to A left hand ball will be required for the 3 through 12 inch Series B and the 14 to 20 inch, with or without 2. Mounting Styles and Positions (also see table 3)Notes: Position 1 is standard; positions 2 through 4 (shown in dotted lines) are By Emerson definition:D Forward flow is into the face side of the disk , or ball sealing Reverse flow is into the hub side of the disk or AA1579 5 LEFT HANDMOUNTINGSTYLE CSTYLE DSTYLE BSTYLE ARIGHT HANDMOUNTINGSTYLE ASTYLE BSTYLE DSTYLE CPOSITION 1 POSITION 1 FLOWPOSITION 1 POSITION 1 FLOW432433344222 STYLESRIGHT HAND MOUNTINGLEFT HAND MOUNTING1111 InstallationThe Actuator is normally positioned vertically in ahorizontal pipeline.

9 However, four mounting stylesand four positions are possible for each style (seefigure 2).When looking in the direction of flow in the pipeline,an Actuator is right hand mounted when it is on theright side of the pipeline, and an Actuator is left handmounted when it is mounted on the left side of ActuatorD100095X012 Product :1061 August 2017 5 Figure 3. Fisher 1078 Declutchable Manual Actuator41B0314 ABy Emerson Automation Solutions definition, forwardflow is into the face side of the disk or ball, and reverseflow is into the hub side of the disk or for the 1061 Actuator are shown in figure6. These dimensions should be used in conjunctionwith the mounting positions shown in figure Locking MechanismThe 1061 Actuator (sizes 30 through 100) is availablewith a locking mechanism which may be used to keepthe Actuator in the locked position duringmaintenance shutdowns (see figures 4 and 5).

10 Thedevice is intended to prevent accidental operation ofthe valve during shutdown and does not imply orqualify a control valve as a safety shutdown Travel StopsAn adjustable down travel stop for the 1061 size 30,40, 60, and 68 actuators is installed in a specialactuator housing. The assembly consists of lockingscrews, locknut, special end rod bearing, and used here, down or downward means in a directiontoward the valve shaft and away from the piston anddiaphragm. Up or upward means in a direction awayfrom the valve shaft and toward the piston locking screw can be positioned to limit downwardtravel of the Actuator lever to any rotation between 0and 90 degrees. The travel stop is installed similar tothe locking mechanism shown in figure 4, except thetravel stop does not accommodate a padlock and thetravel stop can be completely unscrewed from adjustable up travel stop for the 1061 sizes 40through 100 actuators is installed in the top of aspecial Actuator cylinder.