Example: quiz answers

Product Bulletin ValveLink Software October 2017 …

SoftwareValveLink SoloValveLink SNAP ON ValveLink DTMV alveLink PLUG IN for PRM Communicate with both HART andFOUNDATION Fieldbus FIELDVUE digital valvecontrollers Configure, calibrate, and diagnose FIELDVUE instruments from one location Use Stabilize & Optimize and PerformanceTuner to easily optimize tuning Performance Diagnostics provide in servicediagnostics for monitoring the health of thevalve assembly without disturbing theprocess Diagnostics provide validation of assemblyrebuild and detailed insight into the physicalcondition of the valve/actuator assembly Setup and test FIELDVUE instruments forSafety Instrumented System (SIS) Solutions Solenoid Valve Test to test and monitor thehealth of the solenoid connected to the valveassembly (SIS only) Scheduler allows you to specify a time anddate to automatically run tasks on a regularbasis Ability to preconfigure calibration anddiagnostics in the workshop with BatchRunner or setup your own Macro file Time saving Concurrent Batch allowsexecuting a diagnostic test or Calibration onmultiple valves at the same time Merge Database feature provides the abilityto automate multiple ValveLink databasesand tags to a single or multiple stations ValveLink Express licensing allows you toobtain a free version of ValveLink softwarethat allows FIELDVUE instrument setup,calibr

Trend Travel, Pressure, and Drive Signal ValveLink Software D102227X012 Product Bulletin 62.1:ValveLink Software October 2017 3 Communicate with both HART and FOUNDATION fieldbus

Tags:

  Product, Software, Bulletin, Product bulletin valvelink software, Valvelink

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Product Bulletin ValveLink Software October 2017 …

1 SoftwareValveLink SoloValveLink SNAP ON ValveLink DTMV alveLink PLUG IN for PRM Communicate with both HART andFOUNDATION Fieldbus FIELDVUE digital valvecontrollers Configure, calibrate, and diagnose FIELDVUE instruments from one location Use Stabilize & Optimize and PerformanceTuner to easily optimize tuning Performance Diagnostics provide in servicediagnostics for monitoring the health of thevalve assembly without disturbing theprocess Diagnostics provide validation of assemblyrebuild and detailed insight into the physicalcondition of the valve/actuator assembly Setup and test FIELDVUE instruments forSafety Instrumented System (SIS) Solutions Solenoid Valve Test to test and monitor thehealth of the solenoid connected to the valveassembly (SIS only) Scheduler allows you to specify a time anddate to automatically run tasks on a regularbasis Ability to preconfigure calibration anddiagnostics in the workshop with BatchRunner or setup your own Macro file Time saving Concurrent Batch allowsexecuting a diagnostic test or Calibration onmultiple valves at the same time Merge Database feature provides the abilityto automate multiple ValveLink databasesand tags to a single or multiple stations ValveLink Express licensing allows you toobtain a free version of ValveLink softwarethat allows FIELDVUE instrument setup,calibration and verification Generate diagnostic, calibration, andconfiguration reports in Microsoft Wordand PDF formatValveLink SoftwareD102227X012 Product : ValveLink SoftwareOctober 2017 ValveLink SoftwareD102227X012 Product .

2 ValveLink SoftwareOctober 2017 2 ValveLink Software Product SuiteValveLink Software is available in a variety of configurations to allow you to realize the full benefit of FIELDVUE digitalvalve SoloValveLink Solo permits users to perform configuration, calibration, anddiagnostics on HART and FOUNDATION Fieldbus FIELDVUE digital valve ValveLink Software into AMS Device ManagerValveLink SNAP ON provides integration with AMS Device Manager to performconfiguration, calibration, and diagnostics. Integration with AMS Device Managerprovides the ability to communicate with FIELDVUE digital valve controllers viaDeltaV , Ovation , PROVOX , HART multiplexers, and HART Emerson host integration, including Invensys and Honeywell (HART only)systems, can be provided through HSI (Host System Integration).Integrate ValveLink DTM into Field Device Tool - FDTV alveLink DTM provides integration into a Field Device Tool frame application toperform configuration, calibration, and diagnostics on FIELDVUE digital valvecontrollers.

3 The ValveLink DTM is certified with the FDT ValveLink Software into the Yokogawa Plant ResourceManager (PRM) ValveLink PLUG IN for PRM provides integration with the Yokogawa PlantResource Manager (PRM). This integration provides PRM users with the ability tolaunch the ValveLink PLUG IN for PRM directly from PRM and to communicatewith HART and FOUNDATION fieldbus FIELDVUE digital valve controllers throughPRM and the Yokogawa CENTUM CS 3000 R3 and CENTRUM Travel, Pressure, and Drive SignalValveLink SoftwareD102227X012 Product : ValveLink SoftwareOctober 2017 3 Communicate with both HART and FOUNDATION fieldbusFIELDVUE digital valve controllersIntegrated or standalone ValveLink Software remotely communicates with HART FIELDVUE instruments over theexisting 4 20 mA signal wiring using the HART communication standard. The same Software also can communicatewith FOUNDATION Fieldbus FIELDVUE instruments over the fieldbus H1 segment.

4 Information is presented in aconsistent, easy to interpret interface that provides the capability to configure, calibrate, and diagnose FIELDVUE instruments from one location: Dashboard of critical instrument information A device connection view of all connected instruments Monitoring of instrument operational parameters and alerts, including Field Diagnostic alerts Review and comparison of diagnostic graphs Instrument setup and calibration Data import and export Schedule diagnostic tests Time-Saving tools such as Batch Runner and Concurrent Batch RunnerTREND VALVE TRAVEL AND PRESSUREA lert categorizationDevice alerts, such as Travel Deviation, are permanentlymapped to a Field Diagnostic Alert in FOUNDATION Fieldbusapplications. Multiple Field Diagnostic categories can beselected per Field Diagnostic applications allow one Field DiagnosticCategory per Field Diagnostic AlertStatus MonitorStatus MonitorIN THE FIELDON THE BENCHV alveLink SoftwareD102227X012 Product : ValveLink SoftwareOctober 2017 4 Field Diagnostic Alerts, which follow the NAMUR NE107 Standard, allow categorization of Device Alerts with thehighest severity displayed on the dashboard.

5 Standalone ValveLink Software can use the Emerson USB Fieldbus Interface, as well as the National Instruments(NI-Fbus) interface to connect to Fieldbus FIELDVUE instruments (DVC6200f and DVC6000f) to configure, calibrate,and diagnose the device on a bench or in the field:Performance Diagnostics tests are available upon user request or a pre selected daily, weekly,monthly, or yearly schedule without user intervention for HART instrumentsPerformance Diagnostics are continually running in FOUNDATION Fieldbus Instrumentsand do not need to be initiated by ValveLink softwareValveLink SoftwareD102227X012 Product : ValveLink SoftwareOctober 2017 5 Use the Performance Tuner to easily optimize tuningThe Performance Tuner lets you easily adjust a FIELDVUE digital valve controller for optimum performance. Whenmounting a FIELDVUE digital valve controller, to either a Fisher or a non Fisher valve, the Performance Tuner canoptimize valve performance for Diagnostics provide in service diagnostics formonitoring the health of the valve assembly withoutdisturbing the processPerformance Diagnostics (PD) provides predictive in service diagnostics for monitoring the health of the valveassembly and customized diagnostics for advanced troubleshooting.

6 Performance Diagnostics continuously analyzethe valve assembly and passively gather data without disturbing or interrupting the control valve while it is in may be used to help detect problems with air leakage, valve assembly friction and deadband, instrument airquality, loose connections, supply pressure restriction, and valve assembly calibration. When a problem is identified,the diagnostic provides a description and severity of the problem, a probable cause, and recommended service diagnostics for troubleshooting allow custom diagnostics to be set up to collect data at a high frequencycollection rate and present the data in a graphical Diagnostics provide on line/in servicepredictive diagnostics to identify faults and list possiblecauses and recommended corrective actions for each faultValveLink SoftwareD102227X012 Product : ValveLink SoftwareOctober 2017 6 Provide Real Time Notification of Current and PotentialValve and Instrument Problems using PerformanceDiagnosticsPerformance Diagnosticsenable the use of diagnosticswhile the valve is in serviceand operating withoutdisturbing the process.

7 Testscan be performed to identifyproblems with the entirecontrol valve assembly, suchas: Red/Yellow/Green condition indicator provides a quick visual indication of the following: the physical condition of the FIELDVUE instrument pneumatic components instrument air supply pressureand volume relay adjustment on double actingpiston actuators the total air received and used by the instrument, and why a valve assembly is deviatingfrom the set point PD One Button is a sweep of the above tests. When the sweep is complete, ValveLink Software will show any errors, possible causes, and recommended actions to resolve the error(s). Friction and Deadband TrendingPerformance Diagnostics tests are available upon userrequest or a pre selected daily, weekly, monthly, oryearly schedule without user intervention for HART instruments. Performance Diagnostics are continuallyrunning in Foundation Fieldbus Instruments and donot need to be initiated by ValveLink Analyzer Boundary Editor allows you to usedefault or customized test criteriaDiagnostic tests, such as the Valve Signature Diagnosticexample shown here, help you detect emerging valverepair requirements before they impact performanceValveLink Software enables simultaneousmultiple overlay of tests (up to ten).

8 Thisallows you to trend valve in to examinevalve movement andother detailsBOUNDARY RESULTSPASS/FAIL RESULTV alveLink SoftwareD102227X012 Product : ValveLink SoftwareOctober 2017 7 Provide validation of assembly rebuild and detailed insightinto the physical condition of the valve/actuator assemblyPerformance Diagnostics monitor the digital valve controller set point and plot valve operation to provide insight intothe dynamic performance of the valve/actuator assembly. Out of service diagnostics such as valve signature, dynamicerror band, and step response assist in the identification of emerging valve problems quickly and out-of-service diagnostics to prioritize and planmaintenance activities when the process is shut Valve Signature diagnostic is used to: Evaluate valve friction, deadband, and shutoff capability. Calculate actuator spring rate and bench set. Identify potential packing problems.

9 Compare current condition to previous baseline condition. Signature Analyzer enables rapid analysis of the Valve Signature to more efficiently manage your plant assets. Based on default or user defined settings, Signature Analyzer provides pass/fail results for Maximum Friction, Minimum Friction, Stem Integrity, and Stick Slip, enabling better documentation for required maintenance or validation of valve Dynamic Error Band diagnostic is used toanalyze hysteresis, deadband, and dynamic Step Response tests to verify instrumenttuning and valve response to signal changesSelect pre-configured Step Tests to evaluate the same time the instrument performs the partialstroke test, ValveLink Software also gathers diagnosticdata. Use this data to evaluate valve performance anddetermine if maintenance is SoftwareD102227X012 Product : ValveLink SoftwareOctober 2017 8 The Step Response diagnostic allows you to evaluate how well the valve tracks an input change.

10 By minimizing deadtime, deadband, and overshoot, process control is greatly enhanced. With the Step Response test you can: Validate tuning parameters. Obtain a numerical analysis for overshoot, hysteresis, dead time, t63, and t86. Define up to 30 and test FIELDVUE instruments for Safety Instrumented System(SIS) SolutionsUse ValveLink Software to set up and test the final control element in safety instrumented system applications. ValveLink Software for DVC6200 SIS digital valve controllersprovides: A Setup Wizard to set up the digital valve controller for use in a Safety Instrumented System. The capability to initiate a partial stroke test of the final control element without requiring a process shutdown. You can run a partial stroke test to prove the valve will respond on demand. ValveLink Software enables the Solenoid Valve Test for SIS instruments. This is to verify that a solenoid used in conjunction with a DVC6200 SIS digital valve controller is Trigger event, based on one of eight processvariables, documents a Safety Demand eventwhen used in a safety instrumented systemValveLink SoftwareD102227X012 Product : ValveLink SoftwareOctober 2017 9 Each PST will be scored as Red/Yellow/Green based on a user selection of acceptance (Abort or Abnormal) criteria and result criticality.