Blower Coil Air HandlerModels BCHD, BCVD, and BCCDAir Terminal Device, 400-3000 CFMO ctober 2021 BCX-PRC001H-ENProduct Catalog 2021 Trane BCX-PRC001H-ENIntroductionTrane Blower Coils Factory Packaged How You Need You Need ItFigure Blower coil (BCHD model)Unit sizes 12, 18, 24,36, 54, 72, 90 MBhKnockouts in all fourcorners for hanger rods1/2 - 3 HP ECM motor (standard)Direct-drive up inches total staticeliminates the difficultieswith beltsControl box optionsinclude UC400-B controllerfor single zone VAV; CSTI, ZN520 Main coil with coppertubes and enhances aluminum fins in 2-, 4-, or 6-row hydronicor 4- and 6-row DXThrowaway MERV 8 or MERV 13 filtersInternal filter frame accommodates 1-inchor 2-inch filtersMain and auxiliary drain connections on same side of unitBCX-PRC001H-EN3 IntroductionFigure vertical Blower coil (BCCD model)Unit sizes 24, 36, 48, 60 MBh1/2 - 1 HP ECM motor (standard)Direct-drive up inches total staticeliminates the difficultieswith beltsControl box optionsinclude UC400-B controllerfor single zone VAV; CSTI,ZN520 Main coil with coppertubes and enhances aluminum fins in 4- or 6-row hydronicor 3-, 4-, and 6-row DXThrowaway MERV 8 or MERV 13 filtersInternal filter frame accommodates 1-inchor 2-inch filtersMain drain connectionon same side of unitAuxillary heating coilwith 1- or 2-row hydronic4 BCX-PRC001H-ENIntroductionCopyrightThis document and the information in it are the property of Trane, and may not be used or reproduced i

result in lower operati ng costs and improved occu pant comfort compared to constant-speed units. Controls Trane offers a broad array of control options, from a simple control interface (CSTI) to the Tracer ® controllers. Thermostat All controls are factory-mounted and tested to minimize field setup and improve reliability. Factory

Tags:

  Improved

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Product Catalog Blower Coil Air Handler Models BCHD, BCVD ...

1 Blower Coil Air HandlerModels BCHD, BCVD, and BCCDAir Terminal Device, 400-3000 CFMO ctober 2021 BCX-PRC001H-ENProduct Catalog 2021 Trane BCX-PRC001H-ENIntroductionTrane Blower Coils Factory Packaged How You Need You Need ItFigure Blower coil (BCHD model)Unit sizes 12, 18, 24,36, 54, 72, 90 MBhKnockouts in all fourcorners for hanger rods1/2 - 3 HP ECM motor (standard)Direct-drive up inches total staticeliminates the difficultieswith beltsControl box optionsinclude UC400-B controllerfor single zone VAV; CSTI, ZN520 Main coil with coppertubes and enhances aluminum fins in 2-, 4-, or 6-row hydronicor 4- and 6-row DXThrowaway MERV 8 or MERV 13 filtersInternal filter frame accommodates 1-inchor 2-inch filtersMain and auxiliary drain connections on same side of unitBCX-PRC001H-EN3 IntroductionFigure vertical Blower coil (BCCD model)Unit sizes 24, 36, 48, 60 MBh1/2 - 1 HP ECM motor (standard)Direct-drive up inches total staticeliminates the difficultieswith beltsControl box optionsinclude UC400-B controllerfor single zone VAV.

2 CSTI,ZN520 Main coil with coppertubes and enhances aluminum fins in 4- or 6-row hydronicor 3-, 4-, and 6-row DXThrowaway MERV 8 or MERV 13 filtersInternal filter frame accommodates 1-inchor 2-inch filtersMain drain connectionon same side of unitAuxillary heating coilwith 1- or 2-row hydronic4 BCX-PRC001H-ENIntroductionCopyrightThis document and the information in it are the property of Trane, and may not be used or reproduced in whole or in part without written permission. Trane reserves the right to revise this publication at any time, and to make changes to its content without obligation to notify any person of such revision or trademarks referenced in this document are the trademarks of their respective HistoryUpdated OSHPD Seismic Certifcation section in the Mechnical Specification of ContentsIntroduction .. 2 Trane Blower Coils Factory Packaged How You Need You Need It .. 2 Features and Benefits .. 9 Single Source Responsibility .. 9 Piping Packages.

3 10 Energy Efficiency .. 10 Controls .. 10 Thermostat .. 10 CSTI .. 10 Tracer Controllers .. 10 End Devices .. 11 Flexibility .. 11 Coil Options .. 11 Filter Placement Options .. 11 Motor Options .. 11 Indoor Air Quality .. 12 Drain Pans .. 12 Filtration .. 12 Ventilation .. 12 Dehumidification .. 12 Easy to Service .. 13 Durability .. 13 Optional Accessory Sections .. 13 Mixing Box .. 13 Angle Filter or Angle Filter/Mixing Box Combination .. 13 Electric Heat .. 14 Steam Coils .. 14 Application Considerations .. 15 Single-Zone, Constant Volume Applications .. 15 Two-Pipe Hydronic Units .. 15 Two-Pipe Hydronic Units With Electric Heat .. 15 Four-Pipe Hydronic Units .. 16 Economizer .. 16DX Cooling Units .. 16 Dehumidification .. 16 Four-Pipe Unit with Reheat .. 17 Chilled-Water Reset .. 17 Location and Installation .. 17 Acoustics .. 17 Operating Limitations .. 186 BCX-PRC001H-ENTable of ContentsTypical Blower Coil Applications.

4 18 Selection Procedure .. 22 Selecting a Unit .. 22 Cooling Selection Example .. 23 Heating Selection Example .. 24 Model Number Description .. 25 General Data .. 27 Valve Package Waterflow Limits .. 30 Coil Circuiting .. 30 Performance Data .. 31 Air Pressure Drop Adjustments .. 31 Water Pressure Drop .. 35 Fan arrangements .. 44 Fan Curves .. 45 Chilled Water Cooling Capacities .. 60 High-Capacity Chilled Water Cooling Capacities .. 62R-410A, DX Cooling Capacities .. 70 Hot Water Heating Capacities .. 82 Distributor Selection .. 86 Controls .. 87 Why Trane Controls? .. 87 VelociTach Motor Control Board .. 88 Control Options .. 88 Manual Fan Speed Switch .. 89 Customer Supplied Terminal Interface (CSTI) .. 89 Tracer Controllers .. 90 Thermostat .. 90 Tracer ZN520 Controller .. 90 Tracer UC400-B Controller .. 91 Tracer Controller Features .. 91 Features Available on All Controllers .. 91 Additional Features.

5 93 Tracer Controls Sequence of Operation .. 95 Fan Speed Switch (units with 3-speed fan only) .. 95 Thermostat .. 95 Tracer ZN520 and UC400-B .. 95 Air-Fi Wireless Systems .. 95 Air-Fi Wireless Communications Interface (WCI) .. 96 Air-Fi Wireless Communications Sensor (WCS) .. 96 Wireless Zone Sensor (WZS) Set .. 96 BCX-PRC001H-EN7 Table of ContentsZone Sensor Options .. 97 End Device Options .. 98 Low Temperature Detection .. 98 Condensate Overflow Detection .. 98 Outside Air Sensor .. 99 Two-Position Mixing Box Damper Actuator .. 99 Discharge Air Sensor .. 99 Economizer Damper Actuator .. 99CO2 Sensor for Demand-Controlled Ventilation .. 99 Humidity Sensor .. 99 Control Valves .. 100 How to Choose the Correct Control Valve .. 100 Electrical Data .. 102 Dimensions and Weights .. 105 Horizontal Blower Coil .. 105 Compact Vertical Blower Coil .. 108 Options .. 110 Angle Filter and Mixing Box .. 110 Bottom or Top Access Filter Box.

6 111 Electric Heat .. 112 Piping Packages .. 119 Basic Piping .. 119 Deluxe Piping .. 121 Mechanical Specifications .. 123 General .. 123 Casings .. 123 Coils .. 123 Hydronic Coils .. 123 Direct Expansion (DX) Coils .. 123 Steam Coils (Type NS) .. 124 Fan .. 124EC Motors .. 124 Drain Pan .. 124 Filters .. 125 Mixing Box .. 125 Electric Heater .. 125 Controls .. 125 Customer Supplied Terminal Interface (CSTI) .. 125 Thermostat .. 125 Tracer ZN520 .. 126 Tracer UC400-B .. 1268 BCX-PRC001H-ENTable of ContentsWireless Comm Interface (WCI) .. 126 Seismic Certification .. 126 IBC Seismic Certification .. 126 OSHPD Seismic Certification .. 126 Piping Packages .. 126 Two Position Control Valves .. 127 Modulating Control Valves .. 127 End Valves .. 127 Ball Valve .. 127 Manual Circuit Setter .. 128 Strainer .. 128 Bypass Balance Valve .. 129 BCX-PRC001H-EN9 Features and BenefitsFactory Packaged What You Need When You Need ItThe Trane Blower coil air Handler , Models BCHD, BCVD, and BCCD, accommodate a variety of applications while providing a low-cost method of air conditioning and/or heating buildings.

7 These compact, low-profile units can fit in small spaces and are floor or ceiling mounted. With a minimum of effort, they can be relocated within the building as needs coils are light-duty air handlers, ranging from to tons nominal capacity. They are typically used in schools, hospitals, offices, stores, and similar applications. Trane Blower coils are UL listed to and Canadian safety standards for all: 115, 208, 230, 277, and 460 volt 60 Hz motors 220, 240, 380, and 415 volt 50 Hz motorsSingle Source ResponsibilityTrane is the single source of responsibility because we ship Blower coils from the factory as a total package. Included in the package are factory-mounted coils, filters, controls, direct-drive motors, and duct collars. Also, factory-provided piping packages are an available option. Because we provide the total package, this helps reduce job site labor and installation 3. Horizontal Blower coil10 BCX-PRC001H-ENFeatures and BenefitsPiping PackagesAll Blower coil air handlers are available with factory-built piping package options for field installation using field-supplied interconnecting piping.

8 Basic or deluxe piping package options are available with a variety of control valve options: Two- or three-way 1/2-in, 3/4-in, 1-in, or 1 1/4-in Two-position or modulatingThe basic piping package consists of two shut-off ball valves. The deluxe piping package has one shut-off ball valve, a strainer, and a circuit setter balancing valve. Basic or deluxe piping packages with a three-way control valve also include a balancing fitting on the bypass line. Energy Efficiency Trane s commitment to providing premium quality products has led to the exclusive use of Electronically Commutated Motors (ECM) in all Blower coil Models . These brushless DC motors incorporate the latest technology for optimized energy efficiency, acoustical abatement, maintenance free and extended motor life. Each motor comes with a VelociTach motor control board that allows for programmability, soft ramp-up, better airflow control, and serial communication. Trane units equipped with ECMs are significantly more efficient than permanent split capacitor (PSC) motors or belt-drive motors and enable single-zone VAV VAV control varies the fan speed as the zone cooling or heating load changes, and can result in lower operating costs and improved occupant comfort compared to constant-speed offers a broad array of control options, from a simple control interface (CSTI) to the Tracer controls are factory-mounted and tested to minimize field setup and improve reliability.

9 Factory provided low voltage wall mounted thermostat is wall-mounted zone sensors/thermostats require only low voltage control wiring from the device to the unit control box (no line voltage). The thermostat is factory configured based on selected control interface is intended to be used with a field-supplied, low-voltage thermostat or controller. The control box contains a disconnect switch (optional for units with electric heat). All end devices are wired to a low-voltage terminal block and are run-tested, so only a power connection and thermostat connection is needed to commission the unit. Changeover sensors and controls are provided when a change-over coil is selected. Tracer ControllersThe Tracer family of controllers ZN520 and UC400-B offers the combined advantages of simple and dependable operation with the latest Trane-designed controller. Standard control features include options normally available on more elaborate control systems. All control options are available factory-configured or can be field-configured using Rover service software for the ZN controllers, the UC400-B is serviced via Tracer TU.

10 This is the industry s first solution that is factory-mounted, wired, and programmed for infinite modulation of fan speed based on space loads, using the Tracer UC400-B. BCX-PRC001H-EN11 Features and BenefitsEnd DevicesOptional factory-mounted end devices such as a condensate float switch, freezestat, control valves, and actuators are available. Factory-installed and -wired electric heat features single-point power Trane Blower coil is available in either horizontal, vertical, or compact vertical configurations. Horizontal units are typically ceiling suspended via threaded rods. Knockouts are provided in all four corners to pass the rods through the unit. Horizontal units can also be floor mounted. Vertical units are typically floor mounted. They have a side inlet for easy duct connection, and do not require a field-fabricated inlet plenum. Vertical units ship in two pieces and can be set up in either a pre-swirl or counter-swirl configuration. Compact vertical units are floor mounted and ship in one piece.